135 research outputs found

    Patient-reported outcomes measures and patient preferences for minimally invasive glaucoma surgical devices.

    Get PDF
    BackgroundMany therapeutic options are available to glaucoma patients. One recent therapeutic option is minimally invasive glaucoma surgical (MIGS) devices. It is unclear how patients view different treatments and which patient-reported outcomes would be most relevant in patients with mild to moderate glaucoma. We developed a questionnaire for patients eligible for MIGS devices and a patient preference study to examine the value patients place on certain outcomes associated with glaucoma and its therapies.ObjectivesTo summarize the progress to date.MethodsQuestionnaire development: We drafted the questionnaire items based on input from one physician and four patient focus groups, and a review of the literature. We tested item clarity with six cognitive interviews. These items were further refined. Patient preference study: We identified important benefit and risk outcomes qualitatively using semi-structured, one-on-one interviews with patients who were eligible for MIGS devices. We then prioritized these outcomes quantitatively using best-worst scaling methods.ResultsQuestionnaire testing: Three concepts were deemed relevant for the questionnaire: functional limitations, symptoms, and psychosocial factors. We will evaluate the reliability and validity of the 52-item draft questionnaire in an upcoming field test. Patient preference study: We identified 13 outcomes that participants perceived as important. Outcomes with the largest relative importance weights were "adequate IOP control" and "drive a car during the day."ConclusionsPatients have the potential to steer clinical research towards outcomes that are important to them. Incorporating patients' perspectives into the MIGS device development and evaluation process may expedite innovation and availability of these devices

    Is post-trabeculectomy hypotony a risk factor for subsequent failure? A case control study

    Get PDF
    BACKGROUND: Ocular hypotony results in an increased break down of the blood-aqueous barrier and an increase in inflammatory mediator release. We postulate that this release may lead to an increased risk of trabeculectomy failure through increased bleb scarring. This study was designed to try to address the question if hypotony within one month of trabeculectomy for Primary Open Angle Glaucoma (POAG), is a risk factor for future failure of the filter. METHODS: We performed a retrospective, case notes review, of patients who underwent trabeculectomy for POAG between Jan 1995 and Jan 1996 at our hospital. We identified those with postoperative hypotony within 1 month of surgery. Hypotony was defined as an intraocular pressure (IOP) < 8 mmHg or an IOP of less than 10 mmHg with choroidal detachment or a shallow anterior chamber. We compared the survival times of the surgery in this group with a control group (who did not suffer hypotony as described above), over a 5 year period. Failure of trabeculectomy was defined as IOP > 21 mmHg, or commencement of topical antihypertensives or repeat surgery. RESULTS: 97 cases matched our inclusion criteria, of these 38 (39%) experienced hypotony within 1 month of surgery. We compared the survival times in those patients who developed hypotony with those who did not using the log-rank test. This data provided evidence of a difference (P = 0.0492) with patients in the hypotony group failing more rapidly than the control group. CONCLUSION: Early post-trabeculectomy hypotony (within 1 month) is associated with reduced survival time of blebs

    Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile

    Get PDF
    Background: Glaucoma is the leading cause of irreversible blindness worldwide. It is a heterogeneous group of conditions with a common optic neuropathy and associated loss of peripheral vision. Both over and under-diagnosis carry high costs in terms of healthcare spending and preventable blindness. The characteristic clinical feature of glaucoma is asymmetrical optic nerve rim narrowing, which is difficult for humans to quantify reliably. Strategies to improve and automate optic disc assessment are therefore needed to prevent sight loss. Methods: We developed a novel glaucoma detection algorithm that segments and analyses colour photographs to quantify optic nerve rim consistency around the whole disc at 15-degree intervals. This provides a profile of the cup/disc ratio, in contrast to the vertical cup/disc ratio in common use. We introduce a spatial probabilistic model, to account for the optic nerve shape, we then use this model to derive a disc deformation index and a decision rule for glaucoma. We tested our algorithm on two separate image datasets (ORIGA and RIM-ONE). Results: The spatial algorithm accurately distinguished glaucomatous and healthy discs on internal and external validation (AUROC 99.6% and 91.0% respectively). It achieves this using a dataset 100-times smaller than that required for deep learning algorithms, is flexible to the type of cup and disc segmentation (automated or semi-automated), utilises images with missing data, and is correlated with the disc size (p = 0.02) and the rim-to-disc at the narrowest rim (p<0.001, in external validation). Discussion: The spatial probabilistic algorithm is highly accurate, highly data efficient and it extends to any imaging hardware in which the boundaries of cup and disc can be segmented, thus making the algorithm particularly applicable to research into disease mechanisms, and also glaucoma screening in low resource settings

    Consensus generation of a minimum set of outcome measures for auditing glaucoma surgery outcomes—a Delphi exercise

    Get PDF
    Purpose: To identify the key set of glaucoma surgery outcome measures considered most important and practical to collect by glaucoma specialists. Methods: One hundred two glaucoma specialists (57 members of the UK and Eire Glaucoma Society (UKEGS) and 45 members of the European Glaucoma society (EGS)) took part in an Online Delphi exercise. The RAND/UCLA appropriateness method was used analyse data from each round and generate a disagreement index. Results: Participants agreed on 13 baseline data points and 12 outcomes that were considered important and practical to collect. For intraocular pressure (IOP) percentage reduction in IOP from baseline (last three IOP readings pre-op) and reduction below a specified target were considered important. For visual fields, change in a global visual field index, e.g. MD, and development of progression as assessed by linear regression were considered important. From a safety perspective, any visual loss resulting in a doubling of the minimal angle of resolution, loss of 5 dB or more of visual field or development of advanced field loss (Hodapp Parrish Anderson Stage 4) was considered important. The importance of routinely using patient reported outcome measures (PROMs) was highlighted. Consensus suggested that outcomes of glaucoma treatments should be reported at 1, 5 and 10 years. Conclusions: There was broad consensus on a minimum dataset for reporting the outcomes of glaucoma surgery and outcome measurement intervals

    24-h Efficacy of Glaucoma Treatment Options

    Full text link

    Corticosteroids in ophthalmology : drug delivery innovations, pharmacology, clinical applications, and future perspectives

    Get PDF

    Genomic reconstruction of the SARS-CoV-2 epidemic in England.

    Get PDF
    The evolution of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus leads to new variants that warrant timely epidemiological characterization. Here we use the dense genomic surveillance data generated by the COVID-19 Genomics UK Consortium to reconstruct the dynamics of 71 different lineages in each of 315 English local authorities between September 2020 and June 2021. This analysis reveals a series of subepidemics that peaked in early autumn 2020, followed by a jump in transmissibility of the B.1.1.7/Alpha lineage. The Alpha variant grew when other lineages declined during the second national lockdown and regionally tiered restrictions between November and December 2020. A third more stringent national lockdown suppressed the Alpha variant and eliminated nearly all other lineages in early 2021. Yet a series of variants (most of which contained the spike E484K mutation) defied these trends and persisted at moderately increasing proportions. However, by accounting for sustained introductions, we found that the transmissibility of these variants is unlikely to have exceeded the transmissibility of the Alpha variant. Finally, B.1.617.2/Delta was repeatedly introduced in England and grew rapidly in early summer 2021, constituting approximately 98% of sampled SARS-CoV-2 genomes on 26 June 2021
    corecore