69 research outputs found

    Kinematic and kinetic analysis of the goalkeeper’s diving save in football

    Get PDF
    Kinetics and full body kinematics were measured in ten elite goalkeepers diving to save high and low balls at both sides of the goal, aiming to investigate their starting position, linear and angular momentum, and legs' contribution to end-performance. Our results showed that goalkeepers adopted a starting position with a stance width of 33 ± 1% of leg length, knee flexion angle of 62 ± 18° and hip flexion angle of 63 ± 18°. The contralateral leg contributed more than the ipsilateral leg to COM velocity (p < 0.01), both for the horizontal (2.7 ± 0.1 m·s−1 versus 1.2 ± 0.1 m·s−1) and for the vertical component (3.1 ± 0.3 m·s−1 versus 0.4 ± 0.2 m·s−1). Peak horizontal and peak angular momenta were significantly larger (p < 0.01) for low dives than for high dives with a mean difference of 55 kg·m·s−1 and 9 kg·m2·s−1, respectively. In addition, peak vertical momentum was significantly larger (p < 0.01) for high dives with a mean difference between dive heights of 113 kg·m·s−1. Coaches need to highlight horizontal lateral skills and exercises (e.g. sideward push-off, sideward jumps), with emphasis on pushing-off with the contralateral leg, when training and assessing goalkeeper’s physical performance

    The EUTOS long-term survival (ELTS) score is superior to the Sokal score for predicting survival in chronic myeloid leukemia

    Get PDF
    Prognostic scores support clinicians in selecting risk-adjusted treatments and in comparatively assessing different results. For patients with chronic-phase chronic myeloid leukemia (CML), four baseline prognostic scores are commonly used. Our aim was to compare the prognostic performance of the scores and to arrive at an evidence-based score recommendation. In 2949 patients not involved in any score development, higher hazard ratios and concordance indices in any comparison demonstrated the best discrimination of long-term survival with the ELTS score. In a second step, of 5154 patients analyzed to investigate risk group classification differences, 23% (n = 1197) were allocated to high-risk by the Sokal score. Of the 1197 Sokal high-risk patients, 56% were non-high-risk according to the ELTS score and had a significantly more favorable long-term survival prognosis than the 526 high-risk patients according to both scores. The Sokal score identified too many patients as high-risk and relatively few (40%) as low-risk (versus 60% with the ELTS score). Inappropriate risk classification jeopardizes optimal treatment selection. The ELTS score outperformed the Sokal score, the Euro, and the EUTOS score regarding risk group discrimination. The recent recommendation of the European LeukemiaNet for preferred use of the ELTS score was supported with significant statistical evidence.Peer reviewe

    Algorithm for Turning Detection and Analysis Validated under Home-Like Conditions in Patients with Parkinson’s Disease and Older Adults using a 6 Degree-of-Freedom Inertial Measurement Unit at the Lower Back

    Get PDF
    INTRODUCTION Aging and age-associated disorders such as Parkinson's disease (PD) are often associated with turning difficulties, which can lead to falls and fractures. Valid assessment of turning and turning deficits specifically in non-standardized environments may foster specific treatment and prevention of consequences. METHODS Relative orientation, obtained from 3D-accelerometer and 3D-gyroscope data of a sensor worn at the lower back, was used to develop an algorithm for turning detection and qualitative analysis in PD patients and controls in non-standardized environments. The algorithm was validated with a total of 2,304 turns ≄90° extracted from an independent dataset of 20 PD patients during medication ON- and OFF-conditions and 13 older adults. Video observation by two independent clinical observers served as gold standard. RESULTS In PD patients under medication OFF, the algorithm detected turns with a sensitivity of 0.92, a specificity of 0.89, and an accuracy of 0.92. During medication ON, values were 0.92, 0.78, and 0.83. In older adults, the algorithm reached validation values of 0.94, 0.89, and 0.92. Turning magnitude (difference, 0.06°; SEM, 0.14°) and duration (difference, 0.004 s; SEM, 0.005 s) yielded high correlation values with gold standard. Overall accuracy for direction of turning was 0.995. Intra class correlation of the clinical observers was 0.92. CONCLUSION This wearable sensor- and relative orientation-based algorithm yields very high agreement with clinical observation for the detection and evaluation of ≄90° turns under non-standardized conditions in PD patients and older adults. It can be suggested for the assessment of turning in daily life

    Perceived barriers to guideline adherence: A survey among general practitioners

    Get PDF
    Contains fulltext : 97209.pdf (publisher's version ) (Open Access)BACKGROUND: Despite considerable efforts to promote and support guideline use, adherence is often suboptimal. Barriers to adherence vary not only across guidelines but also across recommendations within guidelines. The aim of this study was to assess the perceived barriers to guideline adherence among GPs by focusing on key recommendations within guidelines. METHODS: We conducted a cross-sectional electronic survey among 703 GPs in the Netherlands. Sixteen key recommendations were derived from four national guidelines. Six statements were included to address the attitudes towards guidelines in general. In addition, GPs were asked to rate their perceived adherence (one statement) and the perceived barriers (fourteen statements) for each of the key recommendations, based on an existing framework. RESULTS: 264 GPs (38%) completed the questionnaire. Although 35% of the GPs reported difficulties in changing routines and habits to follow guidelines, 89% believed that following guidelines leads to improved patient care. Perceived adherence varied between 52 and 95% across recommendations (mean: 77%). The most perceived barriers were related to external factors, in particular patient ability and behaviour (mean: 30%) and patient preferences (mean: 23%). Lack of applicability of recommendations in general (mean: 22%) and more specifically to individual patients (mean: 25%) were also frequently perceived as barriers. The scores on perceived barriers differed largely between recommendations [minimum range 14%; maximum range 67%]. CONCLUSIONS: Dutch GPs have a positive attitude towards the NHG guidelines, report high adherence rates and low levels of perceived barriers. However, the perceived adherence and perceived barriers varied largely across recommendations. The most perceived barriers across recommendations are patient related, suggesting that current guidelines do not always adequately incorporate patient preferences, needs and abilities. It may be useful to provide tools such as decision aids, supporting the flexible use of guidelines to individual patients in practice

    Estimating Dynamic Gait Stability Using Data from Non-aligned Inertial Sensors

    Get PDF
    Recently, two methods for quantifying the stability of a dynamical system have been applied to human locomotion: local stability (quantified by finite time maximum Lyapunov exponents, λs and λL) and orbital stability (quantified by maximum Floquet multipliers, MaxFm). In most studies published to date, data from optoelectronic measurement systems were used to calculate these measures. However, using wireless inertial sensors may be more practical as they are easier to use, also in ambulatory applications. While inertial sensors have been employed in some studies, it is unknown whether they lead to similar stability estimates as obtained with optoelectronic measurement systems. In the present study, we compared stability measures of human walking estimated from an optoelectronic measurement system with those calculated from an inertial sensor measurement system. Subjects walked on a treadmill at three different speeds while kinematics were recorded using both measurement systems. From the angular velocities and linear accelerations, λs, λL, and MaxFm were calculated. Both measurement systems showed the same effects of walking speed for all variables. Estimates from both measurement systems correlated high for λs and λL, (R > 0.85) but less strongly for MaxFm (R = 0.66). These results indicate that inertial sensors constitute a valid alternative for an optoelectronic measurement system when assessing dynamic stability in human locomotion, and may thus be used instead, which paves the way to studying gait stability during natural, everyday walking

    Comparative Performance Information Plays No Role in the Referral Behaviour of GPs

    Get PDF
    Comparative performance information (CPI) about the quality of hospital care is information used to identify high-quality hospitals and providers. As the gatekeeper to secondary care, the general practitioner (GP) can use CPI to reflect on the pros and cons of the available options with the patient and choose a provider best fitted to the patient’s needs. We investigated how GPs view their role in using CPI to choose providers and support patients. Method: We used a mixed-method, sequential, exploratory design to conduct explorative interviews with 15 GPs about their referral routines, methods of referral consideration, patient involvement, and the role of CPI. Then we quantified the qualitative results by sending a survey questionnaire to 81 GPs affiliated with a representative national research network. Results: Seventy GPs (86% response rate) filled out the questionnaire. Most GPs did not know where to find CPI (87%) and had never searched for it (94%). The GPs reported that they were not motivated to use CPI due to doubts about its role as support information, uncertainty about the effect of using CPI, lack of faith in better outcomes, and uncertainty about CPI content and validity. Nonetheless, most GPs believed that patients would like to be informed about quality-of- care differences (62%), and about half the GPs discussed quality-of-care differences with their patients (46%), though these discussions were not based on CPI. Conclusion: Decisions about referrals to hospital care are not based on CPI exchanges during GP consultations. As a gatekeeper, the GP is in a good position to guide patients through the enormous amount of quality information that is available. Nevertheless, it is unclear how and whether the GP’s role in using information about quality of care in the referral process can grow, as patients hardly ever initiate a discussion based on CPI, though they seem to be increasingly more critical about differences in quality of care. Future research should address the conditions needed to support GPs’ ability and willingness to use CPI to guide their patients in the referral process

    Prognosis of patients with chronic myeloid leukemia presenting in advanced phase is defined mainly by blast count, but also by age, chromosomal aberrations and hemoglobin

    Get PDF
    Chronic myeloid leukemia (CML) is usually diagnosed in chronic phase, yet there is a small percentage of patients that is diagnosed in accelerated phase or blast crisis. Due to this rarity, little is known about the prognosis of these patients. Our aim was to identify prognostic factors for this cohort. We identified 283 patients in the EUTOS population-based and out-study registries that were diagnosed in advanced phase. Nearly all patients were treated with tyrosine kinase inhibitors. Median survival in this heterogeneous cohort was 8.2 years. When comparing patients with more than 30% blasts to those with 20-29% blasts, the hazard ratio (HR) was 1.32 (95%-confidence interval (CI): [0.7-2.6]). Patients with 20-29% blasts had a significantly higher risk than patients with less than 20% blasts (HR: 2.24, 95%-CI: [1.2-4.0], P = .008). We found that the blast count was the most important prognostic factor; however, age, hemoglobin, basophils and other chromosomal aberrations should be considered as well. The ELTS score was able to define two groups (high risk vs non-high risk) with an HR of 3.01 (95%-CI: [1.81-5.00], P <.001). Regarding the contrasting definitions of blast crisis, our data clearly supported the 20% cut-off over the 30% cut-off in this cohort. Based on our results, we conclude that a one-phase rather than a two-phase categorization of de novo advanced phase CML patients is appropriate.Peer reviewe

    Validation of a Step Detection Algorithm during Straight Walking and Turning in Patients with Parkinson’s Disease and Older Adults Using an Inertial Measurement Unit at the Lower Back

    Get PDF
    INTRODUCTION Inertial measurement units (IMUs) positioned on various body locations allow detailed gait analysis even under unconstrained conditions. From a medical perspective, the assessment of vulnerable populations is of particular relevance, especially in the daily-life environment. Gait analysis algorithms need thorough validation, as many chronic diseases show specific and even unique gait patterns. The aim of this study was therefore to validate an acceleration-based step detection algorithm for patients with Parkinson's disease (PD) and older adults in both a lab-based and home-like environment. METHODS In this prospective observational study, data were captured from a single 6-degrees of freedom IMU (APDM) (3DOF accelerometer and 3DOF gyroscope) worn on the lower back. Detection of heel strike (HS) and toe off (TO) on a treadmill was validated against an optoelectronic system (Vicon) (11 PD patients and 12 older adults). A second independent validation study in the home-like environment was performed against video observation (20 PD patients and 12 older adults) and included step counting during turning and non-turning, defined with a previously published algorithm. RESULTS A continuous wavelet transform (cwt)-based algorithm was developed for step detection with very high agreement with the optoelectronic system. HS detection in PD patients/older adults, respectively, reached 99/99% accuracy. Similar results were obtained for TO (99/100%). In HS detection, Bland-Altman plots showed a mean difference of 0.002 s [95% confidence interval (CI) -0.09 to 0.10] between the algorithm and the optoelectronic system. The Bland-Altman plot for TO detection showed mean differences of 0.00 s (95% CI -0.12 to 0.12). In the home-like assessment, the algorithm for detection of occurrence of steps during turning reached 90% (PD patients)/90% (older adults) sensitivity, 83/88% specificity, and 88/89% accuracy. The detection of steps during non-turning phases reached 91/91% sensitivity, 90/90% specificity, and 91/91% accuracy. CONCLUSION This cwt-based algorithm for step detection measured at the lower back is in high agreement with the optoelectronic system in both PD patients and older adults. This approach and algorithm thus could provide a valuable tool for future research on home-based gait analysis in these vulnerable cohorts

    Second intravenous immunoglobulin dose in patients with Guillain-Barre syndrome with poor prognosis (SID-GBS):a double-blind, randomised, placebo-controlled trial

    Get PDF
    Background Treatment with one standard dose (2 g/kg) of intravenous immunoglobulin is insufficient in a proportion of patients with severe Guillain-Barre syndrome. Worldwide, around 25% of patients severely affected with the syndrome are given a second intravenous immunoglobulin dose (SID), although it has not been proven effective. We aimed to investigate whether a SID is effective in patients with Guillain-Barre syndrome with a predicted poor outcome. Methods In this randomised, double-blind, placebo-controlled trial (SID-GBS), we included patients (>= 12 years) with Guillain-Barre syndrome admitted to one of 59 participating hospitals in the Netherlands. Patients were included on the first day of standard intravenous immunoglobulin treatment (2 g/kg over 5 days). Only patients with a poor prognosis (score of >= 6) according to the modified Erasmus Guillain-Barre syndrome Outcome Score were randomly assigned, via block randomisation stratified by centre, to SID (2 g/kg over 5 days) or to placebo, 7-9 days after inclusion. Patients, outcome adjudicators, monitors, and the steering committee were masked to treatment allocation. The primary outcome measure was the Guillain-Barre syndrome disability score 4 weeks after inclusion. All patients in whom allocated trial medication was started were included in the modified intention-to-treat analysis. Findings Between Feb 16, 2010, and June 5, 2018, 327 of 339 patients assessed for eligibility were included. 112 had a poor prognosis. Of those, 93 patients with a poor prognosis were included in the modified intention-to-treat analysis: 49 (53%) received SID and 44 (47%) received placebo. The adjusted common odds ratio for improvement on the Guillain-Barre syndrome disability score at 4 weeks was 1.4 (95% CI 0.6-3.3; p=0.45). Patients given SID had more serious adverse events (35% vs 16% in the first 30 days), including thromboembolic events, than those in the placebo group. Four patients died in the intervention group (13-24 weeks after randomisation). Interpretation Our study does not provide evidence that patients with Guillain-Barre syndrome with a poor prognosis benefit from a second intravenous immunoglobulin course; moreover, it entails a risk of serious adverse events. Therefore, a second intravenous immunoglobulin course should not be considered for treatment of Guillain-Barre syndrome because of a poor prognosis. The results indicate the need for treatment trials with other immune modulators in patients severely affected by Guillain-Barre syndrome. Funding Prinses Beatrix Spierfonds and Sanquin Plasma Products. Copyright (C) 2021 Elsevier Ltd. All rights reserved
    • 

    corecore