104 research outputs found

    Constraining the string scale: from Planck to Weak and back again

    Full text link
    String and field theory ideas have greatly influenced each other since the so called second string revolution. We review this interrelation paying particular attention to its phenomenological implications. Our guiding principle is the radical shift in the way that we think about the fundamental scale, in particular the way in which string models have been able to accommodate values from the Planck MPl1018M_\mathrm{Pl}\sim 10^{18} GeV down to the electroweak scale MEWM_{EW}\sim TeV.Comment: Invited review aimed at an experimental audienc

    Covariant Description of Flavor Conversion in the LHC Era

    Full text link
    A simple covariant formalism to describe flavor and CP violation in the left-handed quark sector in a model independent way is provided. The introduction of a covariant basis, which makes the standard model approximate symmetry structure manifest, leads to a physical and transparent picture of flavor conversion processes. Our method is particularly useful to derive robust bounds on models with arbitrary mechanisms of alignment. Known constraints on flavor violation in the K and D systems are reproduced in a straightforward manner. Assumptions-free limits, based on top flavor violation at the LHC, are then obtained. In the absence of signal, with 100 fb^{-1} of data, the LHC will exclude weakly coupled (strongly coupled) new physics up to a scale of 0.6 TeV (7.6 TeV), while at present no general constraint can be set related to Delta t=1 processes. LHC data will constrain Delta F=2 contributions via same-sign tops signal, with a model independent exclusion region of 0.08 TeV (1.0 TeV). However, in this case, stronger bounds are found from the study of CP violation in D-bar D mixing with a scale of 0.57 TeV (7.2 TeV). In addition, we apply our analysis to models of supersymmetry and warped extra dimension. The minimal flavor violation framework is also discussed, where the formalism allows to distinguish between the linear and generic non-linear limits within this class of models.Comment: 24 pages, 6 figures. Some corrections and clarifications; references added. Matches published versio

    Les Houches 2011: Physics at TeV Colliders New Physics Working Group Report

    Full text link
    We present the activities of the "New Physics" working group for the "Physics at TeV Colliders" workshop (Les Houches, France, 30 May-17 June, 2011). Our report includes new agreements on formats for interfaces between computational tools, new tool developments, important signatures for searches at the LHC, recommendations for presentation of LHC search results, as well as additional phenomenological studies.Comment: 243 pages, report of the Les Houches 2011 New Physics Group; fix three figure

    The physics case of a 3 TeV muon collider stage

    Get PDF
    In the path towards a muon collider with center of mass energy of 10 TeV ormore, a stage at 3 TeV emerges as an appealing option. Reviewing the physicspotential of such muon collider is the main purpose of this document. In orderto outline the progression of the physics performances across the stages, a fewsensitivity projections for higher energy are also presented. There are manyopportunities for probing new physics at a 3 TeV muon collider. Some of themare in common with the extensively documented physics case of the CLIC 3 TeVenergy stage, and include measuring the Higgs trilinear coupling and testingthe possible composite nature of the Higgs boson and of the top quark at the 20TeV scale. Other opportunities are unique of a 3 TeV muon collider, and stemfrom the fact that muons are collided rather than electrons. This isexemplified by studying the potential to explore the microscopic origin of thecurrent gg-2 and BB-physics anomalies, which are both related with muons.<br

    The physics case of a 3 TeV muon collider stage

    Get PDF
    In the path towards a muon collider with center of mass energy of 10 TeV ormore, a stage at 3 TeV emerges as an appealing option. Reviewing the physicspotential of such muon collider is the main purpose of this document. In orderto outline the progression of the physics performances across the stages, a fewsensitivity projections for higher energy are also presented. There are manyopportunities for probing new physics at a 3 TeV muon collider. Some of themare in common with the extensively documented physics case of the CLIC 3 TeVenergy stage, and include measuring the Higgs trilinear coupling and testingthe possible composite nature of the Higgs boson and of the top quark at the 20TeV scale. Other opportunities are unique of a 3 TeV muon collider, and stemfrom the fact that muons are collided rather than electrons. This isexemplified by studying the potential to explore the microscopic origin of thecurrent gg-2 and BB-physics anomalies, which are both related with muons.<br

    Towards a muon collider

    Get PDF

    HE-LHC: The High-Energy Large Hadron Collider – Future Circular Collider Conceptual Design Report Volume 4

    Get PDF
    In response to the 2013 Update of the European Strategy for Particle Physics (EPPSU), the Future Circular Collider (FCC) study was launched as a world-wide international collaboration hosted by CERN. The FCC study covered an energy-frontier hadron collider (FCC-hh), a highest-luminosity high-energy lepton collider (FCC-ee), the corresponding 100 km tunnel infrastructure, as well as the physics opportunities of these two colliders, and a high-energy LHC, based on FCC-hh technology. This document constitutes the third volume of the FCC Conceptual Design Report, devoted to the hadron collider FCC-hh. It summarizes the FCC-hh physics discovery opportunities, presents the FCC-hh accelerator design, performance reach, and staged operation plan, discusses the underlying technologies, the civil engineering and technical infrastructure, and also sketches a possible implementation. Combining ingredients from the Large Hadron Collider (LHC), the high-luminosity LHC upgrade and adding novel technologies and approaches, the FCC-hh design aims at significantly extending the energy frontier to 100 TeV. Its unprecedented centre-of-mass collision energy will make the FCC-hh a unique instrument to explore physics beyond the Standard Model, offering great direct sensitivity to new physics and discoveries

    FCC-ee: The Lepton Collider – Future Circular Collider Conceptual Design Report Volume 2

    Get PDF

    Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease

    Get PDF
    Background: Experimental and clinical data suggest that reducing inflammation without affecting lipid levels may reduce the risk of cardiovascular disease. Yet, the inflammatory hypothesis of atherothrombosis has remained unproved. Methods: We conducted a randomized, double-blind trial of canakinumab, a therapeutic monoclonal antibody targeting interleukin-1β, involving 10,061 patients with previous myocardial infarction and a high-sensitivity C-reactive protein level of 2 mg or more per liter. The trial compared three doses of canakinumab (50 mg, 150 mg, and 300 mg, administered subcutaneously every 3 months) with placebo. The primary efficacy end point was nonfatal myocardial infarction, nonfatal stroke, or cardiovascular death. RESULTS: At 48 months, the median reduction from baseline in the high-sensitivity C-reactive protein level was 26 percentage points greater in the group that received the 50-mg dose of canakinumab, 37 percentage points greater in the 150-mg group, and 41 percentage points greater in the 300-mg group than in the placebo group. Canakinumab did not reduce lipid levels from baseline. At a median follow-up of 3.7 years, the incidence rate for the primary end point was 4.50 events per 100 person-years in the placebo group, 4.11 events per 100 person-years in the 50-mg group, 3.86 events per 100 person-years in the 150-mg group, and 3.90 events per 100 person-years in the 300-mg group. The hazard ratios as compared with placebo were as follows: in the 50-mg group, 0.93 (95% confidence interval [CI], 0.80 to 1.07; P = 0.30); in the 150-mg group, 0.85 (95% CI, 0.74 to 0.98; P = 0.021); and in the 300-mg group, 0.86 (95% CI, 0.75 to 0.99; P = 0.031). The 150-mg dose, but not the other doses, met the prespecified multiplicity-adjusted threshold for statistical significance for the primary end point and the secondary end point that additionally included hospitalization for unstable angina that led to urgent revascularization (hazard ratio vs. placebo, 0.83; 95% CI, 0.73 to 0.95; P = 0.005). Canakinumab was associated with a higher incidence of fatal infection than was placebo. There was no significant difference in all-cause mortality (hazard ratio for all canakinumab doses vs. placebo, 0.94; 95% CI, 0.83 to 1.06; P = 0.31). Conclusions: Antiinflammatory therapy targeting the interleukin-1β innate immunity pathway with canakinumab at a dose of 150 mg every 3 months led to a significantly lower rate of recurrent cardiovascular events than placebo, independent of lipid-level lowering. (Funded by Novartis; CANTOS ClinicalTrials.gov number, NCT01327846.
    corecore