1,596 research outputs found

    Tracking environmental trends in the Great Bay Estuarine System through comparisons of historical and present-day green and red algal community structure and nutrient content

    Get PDF
    Monitoring macroalgae populations is an effective means of detecting long term water quality changes in estuarine systems. To investigate the environmental status of New Hampshire’s Great Bay National Estuarine Research Reserve, this study assessed the abundance/distribution of macrophytes, particularly Gracilaria and Ulva species, relative to eutrophication patterns; compared historical (1970s-1990s) and current algal biomass/cover at several sites; and compared Ulva and Gracilaria tissue N/P content to ambient and historical levels. Ulva and Gracilaria biomass/cover have increased significantly at several sites. Cover by Ulva species, at seasonal maxima, was over 90 times the value recorded in the 1970s at Lubberland Creek, and exceeded 50% at all sites in the upper estuary. Gracilaria cover was greater than 25% at Depot Road in the upper estuary, whereas the historical measure was 1%. Sequencing of ITS2, rbcL and CO1 revealed the presence of previously undetected Ulva and Gracilaria species, including Gracilaria vermiculophylla (Ohmi) Papenfuss, an invasive species of Asian origin. Gracilaria vermiculophylla has exceeded G. tikvahiae as the dominant Gracilaria species in Great Bay. Historical voucher specimen screening suggests G. vermiculophylla was introduced as recently as 2003. Nitrogen and phosphorus levels are elevated in the estuary. We should expect continued seasonal nuisance algal blooms

    Effect of two behavioural 'nudging' interventions on management decisions for low back pain: A randomised vignette-based study in general practitioners

    Get PDF
    Objective €Nudges' are subtle cognitive cues thought to influence behaviour. We investigated whether embedding nudges in a general practitioner (GP) clinical decision support display can reduce low-value management decisions. Methods Australian GPs completed four clinical vignettes of patients with low back pain. Participants chose from three guideline-concordant and three guideline-discordant (low-value) management options for each vignette, on a computer screen. A 2×2 factorial design randomised participants to two possible nudge interventions: €partition display' nudge (low-value options presented horizontally, high-value options listed vertically) or €default option' nudge (high-value options presented as the default, low-value options presented only after clicking for more). The primary outcome was the proportion of scenarios where practitioners chose at least one of the low-value care options. Results 120 GPs (72% male, 28% female) completed the trial (n=480 vignettes). Participants using a conventional menu display without nudges chose at least one low-value care option in 42% of scenarios. Participants exposed to the default option nudge were 44% less likely to choose at least one low-value care option (OR 0.56, 95%CI 0.37 to 0.85; p=0.006) compared with those not exposed. The partition display nudge had no effect on choice of low-value care (OR 1.08, 95%CI 0.72 to 1.64; p=0.7). There was no interaction between the nudges (OR 0.94, 95% CI 0.41 to 2.15; p=0.89). Interpretation A default option nudge reduced the odds of choosing low-value options for low back pain in clinical vignettes. Embedding high value options as defaults in clinical decision support tools could improve quality of care. More research is needed into how nudges impact clinical decision-making in different contexts

    Changes in Cerebral Oxidative Metabolism during Neonatal Seizures Following Hypoxic-Ischemic Brain Injury.

    Get PDF
    Seizures are common following hypoxic-ischemic brain injury in newborn infants. Prolonged or recurrent seizures have been shown to exacerbate neuronal damage in the developing brain; however, the precise mechanism is not fully understood. Cytochrome-c-oxidase is responsible for more than 90% of ATP production inside mitochondria. Using a novel broadband near-infrared spectroscopy system, we measured the concentration changes in the oxidation state of cerebral cytochrome-c-oxidase (Δ[oxCCO]) and hemodynamics during recurrent neonatal seizures following hypoxic-ischemic encephalopathy in a newborn infant. A rapid increase in Δ[oxCCO] was noted at the onset of seizures along with a rise in the baseline of amplitude-integrated electroencephalogram. Cerebral oxygenation and cerebral blood volume fell just prior to the seizure onset but recovered rapidly during seizures. Δ[oxCCO] during seizures correlated with changes in mean electroencephalogram voltage indicating an increase in neuronal activation and energy demand. The progressive decline in the Δ[oxCCO] baseline during seizures suggests a progressive decrease of mitochondrial oxidative metabolism

    The Suaineadh Project : a stepping stone towards the deployment of large flexible structures in space

    Get PDF
    The Suaineadh project aims at testing the controlled deployment and stabilization of space web. The deployment system is based on a simple yet ingenious control of the centrifugal force that will pull each of the four daughters sections apart. The four daughters are attached onto the four corners of a square web, and will be released from their initial stowed configuration attached to a central hub. Enclosed in the central hub is a specifically designed spinning reaction wheel that controls the rotational speed with a closed loop control fed by measurements from an onboard inertial measurement sensor. Five other such sensors located within the web and central hub provide information on the surface curvature of the web, and progression of the deployment. Suaineadh is currently at an advanced stage of development: all the components are manufactured with the subsystems integrated and are presently awaiting full integration and testing. This paper will present the current status of the Suaineadh project and the results of the most recent set of tests. In particular, the paper will cover the overall mechanical design of the system, the electrical and sensor assemblies, the communication and power systems and the spinning wheel with its control system

    Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%)

    Full text link
    We present measurements of position and angular resolution of drift chambers operated with a Xe,CO2_2(15%) mixture. The results are compared to Monte Carlo simulations and important systematic effects, in particular the dispersive nature of the absorption of transition radiation and non-linearities, are discussed. The measurements were carried out with prototype drift chambers of the ALICE Transition Radiation Detector, but our findings can be generalized to other drift chambers with similar geometry, where the electron drift is perpendicular to the wire planes.Comment: 30 pages, 18 figure

    Inner retinal preservation in rat models of retinal degeneration implanted with subretinal photovoltaic arrays

    Get PDF
    Photovoltaic arrays (PVA) implanted into the subretinal space of patients with retinitis pigmentosa (RP) are designed to electrically stimulate the remaining inner retinal circuitry in response to incident light, thereby recreating a visual signal when photoreceptor function declines or is lost. Preservation of inner retinal circuitry is critical to the fidelity of this transmitted signal to ganglion cells and beyond to higher visual targets. Post-implantation loss of retinal interneurons or excessive glial scarring could diminish and/or eliminate PVA-evoked signal transmission. As such, assessing the morphology of the inner retina in RP animal models with subretinal PVAs is an important step in defining biocompatibility and predicting success of signal transmission. In this study, we used immunohistochemical methods to qualitatively and quantitatively compare inner retinal morphology after the implantation of a PVA in two RP models: the Royal College of Surgeons (RCS) or transgenic S334ter-line 3 (S334ter-3) rhodopsin mutant rat. Two PVA designs were compared. In the RCS rat, we implanted devices in the subretinal space at 4 weeks of age and histologically examined them at 8 weeks of age and found inner retinal morphology preservation with both PVA devices. In the S334ter-3 rat, we implanted devices at 6-12 weeks of age and again, inner retinal morphology was generally preserved with either PVA design 16-26 weeks post-implantation. Specifically, the length of rod bipolar cells and numbers of cholinergic amacrine cells were maintained along with their characteristic inner plexiform lamination patterns. Throughout the implanted retinas we found nonspecific glial reaction, but none showed additional glial scarring at the implant site. Our results indicate that subretinally implanted PVAs are well-tolerated in rodent RP models and that the inner retinal circuitry is preserved, consistent with our published results showing implant-evoked signal transmission

    Space charge in drift chambers operated with the Xe,CO2(15%) mixture

    Full text link
    Using prototype modules of the ALICE Transition Radiation Detector we investigate space charge effects and the dependence of the pion rejection performance on the incident angle of the ionizing particle. The average pulse height distributions in the drift chambers operated with the Xe,CO2(15%) mixture provide quantitative information on the gas gain reduction due to space charge accumulating during the drift of the primary ionization. Our results demonstrate that the pion rejection performance of a TRD is better for tracks which are not at normal incidence to the anode wires. We present detailed simulations of detector signals, which reproduce the measurements and lend strong support to our interpretation of the measurements in terms of space charge effects.Comment: 18 pages, 10 figures, accepted for publication in Nucl.Instrum.Meth. A. Data files available at http://www-alice.gsi.de/tr

    A method of performance estimation for axial-flow turbines

    Get PDF
    A method for calculation of the performance of conventional axial-flow turbines is presented. It makes use of data derived from the analysis of a large number of turbine tests and other associated test work reported elsewhere. The method enables the performance of a turbine to be calculated over a wide part of its full operating range. It is estimated that the tolerance on the absolute values of gas mass flow and peak efficiency will be in the region of ±2.0 per cent for efficiency and ±3 per cent for gas mass flow on present day types of turbine. The method is illustrated by a worked example

    Performance of bulk SiC radiation detectors

    Get PDF
    SiC is a wide-gap material with excellent electrical and physical properties that may make it an important material for some future electronic devices. The most important possible applications of SiC are in hostile environments, such as in car/jet engines, within nuclear reactors, or in outer space. Another area where the material properties, most notably radiation hardness, would be valuable is in the inner tracking detectors of particle physics experiments. Here, we describe the performance of SiC diodes irradiated in the 24 GeV proton beam at CERN. Schottky measurements have been used to probe the irradiated material for changes in I–V characteristics. Other methods, borrowed from III–V research, used to study the irradiated surface include atomic force microscope scans and Raman spectroscopy. These have been used to observe the damage to the materials surface and internal lattice structure. We have also characterised the detection capabilities of bulk semi-insulating SiC for α radiation. By measuring the charge collection efficiency (CCE) for variations in bias voltage, CCE values up to 100% have been measured
    corecore