262 research outputs found

    Retrieval of ozone profiles from GOMOS limb scattered measurements

    Get PDF
    The GOMOS (Global Ozone Monitoring by Occultation of Stars) instrument on board the Envisat satellite measures the vertical composition of the atmosphere using the stellar occultation technique. While the night-time occultations of GOMOS have been proven to be of good quality, the daytime occultations are more challenging due to weaker signal-to-noise ratio. During daytime GOMOS measures limb scattered solar radiation in addition to stellar radiation. In this paper we introduce a retrieval method that determines ozone profiles between 20–60 km from GOMOS limb scattered solar radiances. GOMOS observations contain a considerable amount of stray light at high altitudes. We introduce a method for removing stray light and demonstrate its feasibility by comparing the corrected radiances against those measured by the OSIRIS (Optical Spectrograph & Infra Red Imaging System) instrument. For the retrieval of ozone profiles, a standard onion peeling method is used. The first comparisons with other data sets suggest that the retrieved ozone profiles in 22–50 km are within 10% compared with the GOMOS night-time occultations and within 15% compared with OSIRIS. GOMOS has measured about 350 000 daytime profiles since 2002. The retrieval method presented here makes this large amount of data available for scientific use

    Miniaturization of fluorescence sensing in optofluidic devices

    Get PDF
    International audienceSuccessful development of a micro-total-analysis system (ÎŒTAS, lab-on-a-chip) is strictly related to the degree of miniaturization, integration, autonomy, sensitivity, selectivity, and repeatability of its detector. Fluorescence sensing is an optical detection method used for a large variety of biological and chemical assays, and its full integration within lab-on-a-chip devices remains a challenge. Important achievements were reported during the last few years, including improvements of previously reported methodologies, as well as new integration strategies. However, a universal paradigm remains elusive. This review considers achievements in the field of fluorescence sensing miniaturization, starting from off-chip approaches, representing miniaturized versions of their lab counter-parts, continuing gradually with strategies that aim to fully integrate fluorescence detection on-chip, and reporting the results around integration strategies based on optical-fiber-based designs,optical layer integrated designs, CMOS-based fluorescence sensing, and organic electronics. Further successful development in this field would enable the implementation of sensing networks in specific environments that, when coupled to Internet of-Things (IoT) and artificial intelligence (AI), could provide real-time data collection and, therefore, revolutionize fields like health, environmental, and industrial sensing

    Optofluidic Formaldehyde Sensing: Towards On-Chip Integration

    Get PDF
    International audienceFormaldehyde (HCHO), a chemical compound used in the fabrication process of a broad range of household products, is present indoors as an airborne pollutant due to its high volatility caused by its low boiling point ( T=−19 °C). Miniaturization of analytical systems towards palm-held devices has the potential to provide more efficient and more sensitive tools for real-time monitoring of this hazardous air pollutant. This work presents the initial steps and results of the prototyping process towards on-chip integration of HCHO sensing, based on the Hantzsch reaction coupled to the fluorescence optical sensing methodology. This challenge was divided into two individually addressed problems: (1) efficient airborne HCHO trapping into a microfluidic context and (2) 3,5–diacetyl-1,4-dihydrolutidine (DDL) molecular sensing in low interrogation volumes. Part (2) was addressed in this paper by proposing, fabricating, and testing a fluorescence detection system based on an ultra-low light Complementary metal-oxide-semiconductor (CMOS) image sensor. Two three-layer fluidic cell configurations (quartz–SU-8–quartz and silicon–SU-8–quartz) were tested, with both possessing a 3.5 ”L interrogation volume. Finally, the CMOS-based fluorescence system proved the capability to detect an initial 10 ”g/L formaldehyde concentration fully derivatized into DDL for both the quartz and silicon fluidic cells, but with a higher signal-to-noise ratio (SNR) for the silicon fluidic cell ( SNRsilicon=6.1 ) when compared to the quartz fluidic cell ( SNRquartz=4.9 ). The signal intensity enhancement in the silicon fluidic cell was mainly due to the silicon absorption coefficient at the excitation wavelength, a(λabs=420 nm)=5×104 cm−1 , which is approximately five times higher than the absorption coefficient at the fluorescence emission wavelength, a(λem=515 nm)=9.25×103 cm−

    Metabolism of hexachlorobenzene in humans: association between serum levels and urinary metabolites in a highly exposed population.

    Get PDF
    Serum and urine from 100 subjects of a general population highly exposed to airborne hexachlorobenzene (HCB) were analyzed to obtain new insights into the metabolism of this ubiquitous compound. HCB was detected in all serum samples with concentrations ranging between 1.1 and 953 ng/ml. The major known metabolites of HCB were investigated in urine collected over 24 hr. Pentachlorophenol (PCP) was detected in all urines with values ranging between 0.58 and 13.9 micrograms excreted in 24 hr [mean +/- standard deviation (SD), 2.52 +/- 2.05; geometric mean, 2.05]. A sulfur derivative that, after hydrolysis, yielded pentachlorobenzenethiol (PCBT) could also be identified and quantified in all the urines with values ranging between 0.18 and 84.0 micrograms of PCBT excreted in 24 hr (mean +/- SD, 3.47 +/- 10.8; geometric mean, 1.39). The sulfur derivative assessed as PCBT appeared to be the main metabolite, with urinary concentrations surpassing those of PCP in the subjects with higher HCB accumulation (HCB in serum > 32 ng/ml). PCBT concentration in urine collected over 24 hr showed a very strong association with HCB concentration in serum; the association was stronger in males than in females. An increase of 1 ng/ml of HCB in serum led to an increase of 2.12 micrograms of PCBT excreted in urine collected over 24 hr in males (95% CI, 1.82-2.44) and to an increase of 0.67 microgram of PCBT in females (CI, 0.33-1.09). A weaker association was found between PCP in urine and HCB in serum, which was only statistically significant in males (an increase of 1 ng/ml of HCB in serum led to an increase of 0.63 microgram of PCP excreted in urine collected over 24 hr; (CI, 0.34-0.95). These results show that the formation of the cysteine conjugate is a quantitatively more important metabolic pathway in humans than the formation of PCP. Moreover, the association found suggests that PCBT is a good urinary marker of HCB internal dose and glutathione-mediated metabolism

    Orexinergic Input to Dopaminergic Neurons of the Human Ventral Tegmental Area

    Get PDF
    The mesolimbic reward pathway arising from dopaminergic (DA) neurons of the ventral tegmental area (VTA) has been strongly implicated in reward processing and drug abuse. In rodents, behaviors associated with this projection are profoundly influenced by an orexinergic input from the lateral hypothalamus to the VTA. Because the existence and significance of an analogous orexigenic regulatory mechanism acting in the human VTA have been elusive, here we addressed the possibility that orexinergic neurons provide direct input to DA neurons of the human VTA. Dual-label immunohistochemistry was used and orexinergic projections to the VTA and to DA neurons of the neighboring substantia nigra (SN) were analyzed comparatively in adult male humans and rats. Orexin B-immunoreactive (IR) axons apposed to tyrosine hydroxylase (TH)-IR DA and to non-DA neurons were scarce in the VTA and SN of both species. In the VTA, 15.062.8% of TH-IR perikarya in humans and 3.260.3% in rats received orexin B-IR afferent contacts. On average, 0.2460.05 and 0.0560.005 orexinergic appositions per TH-IR perikaryon were detected in humans and rats, respectively. The majority(86–88%) of randomly encountered orexinergic contacts targeted the dendritic compartment of DA neurons. Finally, DA neurons of the SN also received orexinergic innervation in both species. Based on the observation of five times heavierorexinergic input to TH-IR neurons of the human, compared with the rat, VTA, we propose that orexinergic mechanism acting in the VTA may play just as important roles in reward processing and drug abuse in humans, as already established well in rodents

    Integration of HIV/AIDS services into African primary health care: lessons learned for health system strengthening in Mozambique - a case study

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>In 2004, Mozambique, supported by large increases in international disease-specific funding, initiated a national rapid scale-up of antiretroviral treatment (ART) and HIV care through a vertical "Day Hospital" approach. Though this model showed substantial increases in people receiving treatment, it diverted scarce resources away from the primary health care (PHC) system. In 2005, the Ministry of Health (MOH) began an effort to use HIV/AIDS treatment and care resources as a means to strengthen their PHC system. The MOH worked closely with a number of NGOs to integrate HIV programs more effectively into existing public-sector PHC services.</p> <p>Case Description</p> <p>In 2005, the Ministry of Health and Health Alliance International initiated an effort in two provinces to integrate ART into the existing primary health care system through health units distributed across 23 districts. Integration included: a) placing ART services in existing units; b) retraining existing workers; c) strengthening laboratories, testing, and referral linkages; e) expanding testing in TB wards; f) integrating HIV and antenatal services; and g) improving district-level management. Discussion: By 2008, treatment was available in nearly 67 health facilities in 23 districts. Nearly 30,000 adults were on ART. Over 80,000 enrolled in the HIV/AIDS program. Loss to follow-up from antenatal and TB testing to ART services has declined from 70% to less than 10% in many integrated sites. Average time from HIV testing to ART initiation is significantly faster and adherence to ART is better in smaller peripheral clinics than in vertical day hospitals. Integration has also improved other non-HIV aspects of primary health care.</p> <p>Conclusion</p> <p>The integration approach enables the public sector PHC system to test more patients for HIV, place more patients on ART more quickly and efficiently, reduce loss-to-follow-up, and achieve greater geographic HIV care coverage compared to the vertical model. Through the integration process, HIV resources have been used to rehabilitate PHC infrastructure (including laboratories and pharmacies), strengthen supervision, fill workforce gaps, and improve patient flow between services and facilities in ways that can benefit all programs. Using aid resources to integrate and better link HIV care with existing services can strengthen wider PHC systems.</p

    An assessment of routine primary care health information system data quality in Sofala Province, Mozambique

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Primary health care is recognized as a main driver of equitable health service delivery. For it to function optimally, routine health information systems (HIS) are necessary to ensure adequate provision of health care and the development of appropriate health policies. Concerns about the quality of routine administrative data have undermined their use in resource-limited settings. This evaluation was designed to describe the availability, reliability, and validity of a sample of primary health care HIS data from nine health facilities across three districts in Sofala Province, Mozambique. HIS data were also compared with results from large community-based surveys.</p> <p>Methodology</p> <p>We used a methodology similar to the Global Fund to Fight AIDS, Tuberculosis and Malaria data verification bottom-up audit to assess primary health care HIS data availability and reliability. The quality of HIS data was validated by comparing three key indicators (antenatal care, institutional birth, and third diptheria, pertussis, and tetanus [DPT] immunization) with population-level surveys over time.</p> <p>Results and discussion</p> <p>The data concordance from facility clinical registries to monthly facility reports on five key indicators--the number of first antenatal care visits, institutional births, third DPT immunization, HIV testing, and outpatient consults--was good (80%). When two sites were excluded from the analysis, the concordance was markedly better (92%). Of monthly facility reports for immunization and maternity services, 98% were available in paper form at district health departments and 98% of immunization and maternity services monthly facility reports matched the Ministry of Health electronic database. Population-level health survey and HIS data were strongly correlated (R = 0.73), for institutional birth, first antenatal care visit, and third DPT immunization.</p> <p>Conclusions</p> <p>Our results suggest that in this setting, HIS data are both reliable and consistent, supporting their use in primary health care program monitoring and evaluation. Simple, rapid tools can be used to evaluate routine data and facilitate the rapid identification of problem areas.</p

    A global climatology of the mesospheric sodium layerfrom GOMOS data during the 2002-2008 period

    Get PDF
    This paper presents a climatology of the mesospheric sodium layer built from the processing of 7 years of GOMOS data. With respect to preliminary results already published for the year 2003, a more careful analysis was applied to the averaging of occultations inside the climatological bins (10° in latitude-1 month). Also, the slant path absorption lines of the Na doublet around 589 nm shows evidence of partial saturation that was responsible for an underestimation of the Na concentration in our previous results. The sodium climatology has been validated with respect to the Fort Collins lidar measurements and, to a lesser extent, to the OSIRIS 2003–2004 data. Despite the important natural sodium variability, we have shown that the Na vertical column has a marked semi-annual oscillation at low latitudes that merges into an annual oscillation in the polar regions, a spatial distribution pattern that was unreported so far. The sodium layer seems to be clearly influenced by the mesospheric global circulation and the altitude of the layer shows clear signs of subsidence during polar winter. The climatology has been parameterized by time-latitude robust fits to allow for easy use. Taking into account the non-linearity of the transmittance due to partial saturation, an experimental approach is proposed to derive mesospheric temperatures from limb remote sounding measurements

    Overexpression of transmembrane protein 168 in the mouse nucleus accumbens induces anxiety and sensorimotor gating deficit

    Get PDF
    Transmembrane protein 168 (TMEM168) comprises 697 amino acid residues, including some putative transmembrane domains. It is reported that TMEM168 controls methamphetamine (METH) dependence in the nucleus accumbens (NAc) of mice. Moreover, a strong link between METH dependence-induced adaptive changes in the brain and mood disorders has been evaluated. In the present study, we investigated the effects of accumbal TMEM168 in a battery of behavioral paradigms. The adeno-associated virus (AAV) Tmem168 vector was injected into the NAc of C57BL/6J mice (NAc-TMEM mice). Subsequently, the accumbal TMEM168 mRNA was increased approximately by seven-fold when compared with the NAc-Mock mice (controls). The NAc-TMEM mice reported no change in the locomotor activity, cognitive ability, social interaction, and depression-like behaviors; however, TMEM168 overexpression enhanced anxiety in the elevated-plus maze and light/dark box test. The increased anxiety was reversed by pretreatment with the antianxiety drug diazepam (0.3 mg/kg i.p.). Moreover, the NAc-TMEM mice exhibited decreased prepulse inhibition (PPI) in the startle response test, and the induced schizophrenia-like behavior was reversed by pretreatment with the antipsychotic drug risperidone (0.01 mg/kg i.p.). Furthermore, accumbal TMEM168 overexpression decreased the basal levels of extracellular GABA in the NAc and the high K+ (100 mM)-stimulated GABA elevation; however, the total contents of GABA in the NAc remained unaffected. These results suggest that the TMEM168-regulated GABAergic neuronal system in the NAc might become a novel target while studying the etiology of anxiety and sensorimotor gating deficits
    • 

    corecore