1,295 research outputs found
Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety
Introduction
Intravenous medication administration is widely reported to be error prone. Technologies such as smart pumps have been introduced with a view to reducing these errors. An international comparison could provide evidence of their effectiveness, including consideration of contextual factors such as regulatory systems and local cultures.
Objectives
The aim of this study was to investigate similarities and differences in practices and error types involving intravenous medication administration in the United States and England, and summarise methodological differences necessary to perform these parallel studies.
Methods
We drew on findings of separate point prevalence studies conducted across hospitals in each country. In these, we compared what was being administered at the time of observation with the prescription and relevant policies, errors were classified by type and severity, and proportions of infusions featuring each error type were calculated. We also reviewed what adaptations to the US protocol were needed for England. Authors independently reviewed findings from both studies and proposed themes for comparison. In online meetings, each country’s research team clarified assumptions and explained their findings.
Results
Key themes included commonalities and contrasts in methods, findings, practices and policies. Although US sites made greater use of smart infusion devices, and had more precisely defined requirements around infusion device use, patterns of errors were similar. Differences among clinical contexts within each country were as marked as differences across countries. Regulatory and quality control systems shape practices, but causal relationships are complex.
Conclusion
Infusion administration is a complex adaptive system with multiple interacting agents (professionals, patients, software systems, etc.) that respond in rich ways to their environments; safety depends on complex, interrelated factors
Complex and unexpected dynamics in simple genetic regulatory networks
Peer reviewedPublisher PD
Measurement of the Lifetime Difference Between B_s Mass Eigenstates
We present measurements of the lifetimes and polarization amplitudes for B_s
--> J/psi phi and B_d --> J/psi K*0 decays. Lifetimes of the heavy (H) and
light (L) mass eigenstates in the B_s system are separately measured for the
first time by determining the relative contributions of amplitudes with
definite CP as a function of the decay time. Using 203 +/- 15 B_s decays, we
obtain tau_L = (1.05 +{0.16}/-{0.13} +/- 0.02) ps and tau_H = (2.07
+{0.58}/-{0.46} +/- 0.03) ps. Expressed in terms of the difference DeltaGamma_s
and average Gamma_s, of the decay rates of the two eigenstates, the results are
DeltaGamma_s/Gamma_s = (65 +{25}/-{33} +/- 1)%, and DeltaGamma_s = (0.47
+{0.19}/-{0.24} +/- 0.01) inverse ps.Comment: 8 pages, 3 figures, 2 tables; as published in Physical Review Letters
on 16 March 2005; revisions are for length and typesetting only, no changes
in results or conclusion
Measurement of and Production in Collisions at = 1.96 TeV
The Standard Model predictions for and production are
tested using an integrated luminosity of 200 pb of \ppbar collision data
collected at the Collider Detector at Fermilab. The cross sections are measured
selecting leptonic decays of the and bosons, and photons with
transverse energy GeV that are well separated from leptons. The
production cross sections and kinematic distributions for the and
are compared to SM predictions.Comment: 7 pages, 4 figures, submitted to PR
Top quark mass measurement using the template method at CDF
We present a measurement of the top quark mass in the lepton+jets and
dilepton channels of decays using the template method. The data
sample corresponds to an integrated luminosity of 5.6 fb of
collisions at Tevatron with TeV, collected with the CDF II
detector. The measurement is performed by constructing templates of three
kinematic variables in the lepton+jets and two kinematic variables in the
dilepton channel. The variables are two reconstructed top quark masses from
different jets-to-quarks combinations and the invariant mass of two jets from
the decay in the lepton+jets channel, and a reconstructed top quark mass
and , a variable related to the transverse mass in events with two
missing particles, in the dilepton channel. The simultaneous fit of the
templates from signal and background events in the lepton+jets and dilepton
channels to the data yields a measured top quark mass of Comment: submitted to Phys. Rev.
Evidence for the exclusive decay Bc+- to J/psi pi+- and measurement of the mass of the Bc meson
We report first evidence for a fully reconstructed decay mode of the
B_c^{\pm} meson in the channel B_c^{\pm} \to J/psi \pi^{\pm}, with J/psi \to
mu^+mu^-. The analysis is based on an integrated luminosity of 360 pb$^{-1} in
p\bar{p} collisions at 1.96 TeV center of mass energy collected by the Collider
Detector at Fermilab. We observe 14.6 \pm 4.6 signal events with a background
of 7.1 \pm 0.9 events, and a fit to the J/psi pi^{\pm} mass spectrum yields a
B_c^{\pm} mass of 6285.7 \pm 5.3(stat) \pm 1.2(syst) MeV/c^2. The probability
of a peak of this magnitude occurring by random fluctuation in the search
region is estimated as 0.012%.Comment: 7 pages, 3 figures. Version 3, accepted by PR
Measurement of B(t->Wb)/B(t->Wq) at the Collider Detector at Fermilab
We present a measurement of the ratio of top-quark branching fractions R= B(t
-> Wb)/B(t -> Wq), where q can be a b, s or a d quark, using lepton-plus-jets
and dilepton data sets with integrated luminosity of ~162 pb^{-1} collected
with the Collider Detector at Fermilab during Run II of the Tevatron. The
measurement is derived from the relative numbers of t-tbar events with
different multiplicity of identified secondary vertices. We set a lower limit
of R > 0.61 at 95% confidence level.Comment: 7 pages, 2 figures, published in Physical Review Letters; changes
made to be consistent with published versio
Measurement of the ttbar Production Cross Section in ppbar Collisions at sqrt(s) = 1.96 TeV
We present a measurement of the top quark pair production cross section in
ppbar collisions at sqrt(s)=1.96 TeV using 318 pb^{-1} of data collected with
the Collider Detector at Fermilab. We select ttbar decays into the final states
e nu + jets and mu nu + jets, in which at least one b quark from the t-quark
decays is identified using a secondary vertex-finding algorithm. Assuming a top
quark mass of 178 GeV/c^2, we measure a cross section of 8.7 +-0.9 (stat)
+1.1-0.9 (syst) pb. We also report the first observation of ttbar with
significance greater than 5 sigma in the subsample in which both b quarks are
identified, corresponding to a cross section of 10.1 +1.6-1.4(stat)+2.0-1.3
(syst) pb.Comment: Accepted for publication in Physics Review Letters, 7 page
Measurement of the Dipion Mass Spectrum in X(3872) -> J/Psi Pi+ Pi- Decays
We measure the dipion mass spectrum in X(3872)--> J/Psi Pi+ Pi- decays using
360 pb-1 of pbar-p collisions at 1.96 TeV collected with the CDF II detector.
The spectrum is fit with predictions for odd C-parity (3S1, 1P1, and 3DJ)
charmonia decaying to J/Psi Pi+ Pi-, as well as even C-parity states in which
the pions are from Rho0 decay. The latter case also encompasses exotic
interpretations, such as a D0-D*0Bar molecule. Only the 3S1 and J/Psi Rho
hypotheses are compatible with our data. Since 3S1 is untenable on other
grounds, decay via J/Psi Rho is favored, which implies C=+1 for the X(3872).
Models for different J/Psi-Rho angular momenta L are considered. Flexibility in
the models, especially the introduction of Rho-Omega interference, enable good
descriptions of our data for both L=0 and 1.Comment: 7 pages, 4 figures -- Submitted to Phys. Rev. Let
- …