228 research outputs found

    Does the Unified Protocol Really Change Neuroticism? Results from a Randomized Trial

    Get PDF
    Background Neuroticism is associated with the onset and maintenance of a number of mental health conditions, as well as a number of deleterious outcomes (e.g. physical health problems, higher divorce rates, lost productivity, and increased treatment seeking); thus, the consideration of whether this trait can be addressed in treatment is warranted. To date, outcome research has yielded mixed results regarding neuroticism\u27s responsiveness to treatment, perhaps due to the fact that study interventions are typically designed to target disorder symptoms rather than neuroticism itself. The purpose of the current study was to explore whether a course of treatment with the unified protocol (UP), a transdiagnostic intervention that was explicitly developed to target neuroticism, results in greater reductions in neuroticism compared to gold-standard, symptom focused cognitive behavioral therapy (CBT) protocols and a waitlist (WL) control condition. Method Patients with principal anxiety disorders (N = 223) were included in this study. They completed a validated self-report measure of neuroticism, as well as clinician-rated measures of psychological symptoms. Results At week 16, participants in the UP condition exhibited significantly lower levels of neuroticism than participants in the symptom-focused CBT (t(218) =-2.17, p = 0.03, d =-0.32) and WL conditions(t(207) =-2.33, p = 0.02, d =-0.43), and these group differences remained after controlling for simultaneous fluctuations in depression and anxiety symptoms. Conclusions Treatment effects on neuroticism may be most robust when this trait is explicitly targeted

    Urinary p75(ECD): A prognostic, disease progression, and pharmacodynamic biomarker in ALS.

    Get PDF
    OBJECTIVE: To evaluate urinary neurotrophin receptor p75 extracellular domain (p75(ECD)) levels as disease progression and prognostic biomarkers in amyotrophic lateral sclerosis (ALS). METHODS: The population in this study comprised 45 healthy controls and 54 people with ALS, 31 of whom were sampled longitudinally. Urinary p75(ECD) was measured using an enzyme-linked immunoassay and validation included intra-assay and inter-assay coefficients of variation, effect of circadian rhythm, and stability over time at room temperature, 4°C, and repeated freeze-thaw cycles. Longitudinal changes in urinary p75(ECD) were examined by mixed model analysis, and the prognostic value of baseline p75(ECD) was explored by survival analysis. RESULTS: Confirming our previous findings, p75(ECD) was higher in patients with ALS (5.6 ± 2.2 ng/mg creatinine) compared to controls (3.6 ± 1.4 ng/mg creatinine, p < 0.0001). Assay reproducibility was high, with p75(ECD) showing stability across repeated freeze-thaw cycles, at room temperature and 4°C for 2 days, and no diurnal variation. Urinary p75(ECD) correlated with the revised ALS Functional Rating Scale at first evaluation (r = -0.44, p = 0.008) and across all study visits (r = -0.36, p < 0.0001). p75(ECD) also increased as disease progressed at an average rate of 0.19 ng/mg creatinine per month (p < 0.0001). In multivariate prognostic analysis, bulbar onset (hazard ratio [HR] 3.0, p = 0.0035), rate of disease progression from onset to baseline (HR 4.4, p < 0.0001), and baseline p75(ECD) (HR 1.3, p = 0.0004) were predictors of survival. CONCLUSIONS: The assay for urinary p75(ECD) is analytically robust and shows promise as an ALS biomarker with prognostic, disease progression, and potential pharmacodynamic application. Baseline urinary p75(ECD) provides prognostic information and is currently the only biological fluid-based biomarker of disease progression

    Zephyr: The Fourth Issue

    Get PDF
    This is the fourth issue of Zephyr, the University of New England\u27s journal of creative expression. Since 2000, Zephyr has published original drawings, paintings, photography, prose, and verse created by current and former members of the University community. Zephyr\u27s Editorial Board is made up exclusively of matriculating students.https://dune.une.edu/zephyr/1003/thumbnail.jp

    Discovery of a novel non-narcotic analgesic derived from the CL-20 explosive: Synthesis, pharmacology, and target identification of thiowurtzine, a potent inhibitor of the opioid receptors and the ion channels

    Get PDF
    The number of candidate molecules for new non-narcotic analgesics is extremely limited. Here, we report the identification of thiowurtzine, a new potent analgesic molecule with promising application in chronic pain treatment. We describe the chemical synthesis of this unique compound derived from the hexaazaisowurtzitane (CL-20) explosive molecule. Then, we use animal experiments to assess its analgesic activity in vivo upon chemical, thermal, and mechanical exposures, compared to the effect of several reference drugs. Finally, we investigate the potential receptors of thiowurtzine in order to better understand its complex mechanism of action. We use docking, molecular modeling, and molecular dynamics simulations to identify and characterize the potential targets of the drug and confirm the results of the animal experiments. Our findings finally indicate that thiowurtzine may have a complex mechanism of action by essentially targeting the mu opioid receptor, the TRPA1 ion channel, and the Cav voltage-gated calcium channel

    A comparison of self-reported and device measured sedentary behaviour in adults: a systematic review and meta-analysis

    Get PDF
    © 2020 The Authors. Published by BMC. This is an open access article available under a Creative Commons licence. The published version can be accessed at the following link on the publisher’s website: https://doi.org/10.1186/s12966-020-00938-3BACKGROUND:Sedentary behaviour (SB) is a risk factor for chronic disease and premature mortality. While many individual studies have examined the reliability and validity of various self-report measures for assessing SB, it is not clear, in general, how self-reported SB (e.g., questionnaires, logs, ecological momentary assessments (EMAs)) compares to device measures (e.g., accelerometers, inclinometers). OBJECTIVE:The primary objective of this systematic review was to compare self-report versus device measures of SB in adults. METHODS:Six bibliographic databases were searched to identify all studies which included a comparable self-report and device measure of SB in adults. Risk of bias within and across studies was assessed. Results were synthesized using meta-analyses. RESULTS:The review included 185 unique studies. A total of 123 studies comprising 173 comparisons and data from 55,199 participants were used to examine general criterion validity. The average mean difference was -105.19 minutes/day (95% CI: -127.21, -83.17); self-report underestimated sedentary time by ~1.74 hours/day compared to device measures. Self-reported time spent sedentary at work was ~40 minutes higher than when assessed by devices. Single item measures performed more poorly than multi-item questionnaires, EMAs and logs/diaries. On average, when compared to inclinometers, multi-item questionnaires, EMAs and logs/diaries were not significantly different, but had substantial amount of variability (up to 6 hours/day within individual studies) with approximately half over-reporting and half under-reporting. A total of 54 studies provided an assessment of reliability of a self-report measure, on average the reliability was good (ICC = 0.66). CONCLUSIONS:Evidence from this review suggests that single-item self-report measures generally underestimate sedentary time when compared to device measures. For accuracy, multi-item questionnaires, EMAs and logs/diaries with a shorter recall period should be encouraged above single item questions and longer recall periods if sedentary time is a primary outcome of study. Users should also be aware of the high degree of variability between and within tools. Studies should exert caution when comparing associations between different self-report and device measures with health outcomes. SYSTEMATIC REVIEW REGISTRATION:PROSPERO CRD42019118755.Dr. Stephanie Prince was funded by a Canadian Institutes of Health Research (CIHR) – Public Health Agency of Canada Health System Impact Fellowship. Dr. Jennifer Reed is funded, in part, by a CIHR New Investigator Salary Award. Dr. Jennifer Reed was awarded a Planning and Dissemination Grant (#150435) from the CIHR to support Open Access publication charges.Published versio

    ROS- and Radiation Source-Dependent Modulation of Leukocyte Adhesion to Primary Microvascular Endothelial Cells

    Get PDF
    Anti-inflammatory effects of low-dose irradiation often follow a non-linear dose–effect relationship. These characteristics were also described for the modulation of leukocyte adhesion to endothelial cells. Previous results further revealed a contribution of reactive oxygen species (ROS) and anti-oxidative factors to a reduced leukocyte adhesion. Here, we evaluated the expression of anti-oxidative enzymes and the transcription factor Nrf2 (Nuclear factor-erythroid-2-related factor 2), intracellular ROS content, and leukocyte adhesion in primary human microvascular endothelial cells (HMVEC) upon low-dose irradiation under physiological laminar shear stress or static conditions after irradiation with X-ray or Carbon (C)-ions (0–2 Gy). Laminar conditions contributed to increased mRNA expression of anti-oxidative factors and reduced ROS in HMVEC following a 0.1 Gy X-ray and 0.5 Gy C-ion exposure, corresponding to reduced leukocyte adhesion and expression of adhesion molecules. By contrast, mRNA expression of anti-oxidative markers and adhesion molecules, ROS, and leukocyte adhesion were not altered by irradiation under static conditions. In conclusion, irradiation of endothelial cells with low doses under physiological laminar conditions modulates the mRNA expression of key factors of the anti-oxidative system, the intracellular ROS contents of which contribute at least in part to leucocyte adhesion, dependent on the radiation source

    A comparison of self-reported and device measured sedentary behaviour in adults: a systematic review and meta-analysis

    Get PDF
    Background: Sedentary behaviour (SB) is a risk factor for chronic disease and premature mortality. While many individual studies have examined the reliability and validity of various self-report measures for assessing SB, it is not clear, in general, how self-reported SB (e.g., questionnaires, logs, ecological momentary assessments (EMAs)) compares to device measures (e.g., accelerometers, inclinometers). Objective: The primary objective of this systematic review was to compare self-report versus device measures of SB in adults. Methods: Six bibliographic databases were searched to identify all studies which included a comparable self-report and device measure of SB in adults. Risk of bias within and across studies was assessed. Results were synthesized using meta-analyses. Results: The review included 185 unique studies. A total of 123 studies comprising 173 comparisons and data from 55,199 participants were used to examine general criterion validity. The average mean difference was -105.19 minutes/day (95% CI: -127.21, -83.17); self-report underestimated sedentary time by ~1.74 hours/day compared to device measures. Self-reported time spent sedentary at work was ~40 minutes higher than when assessed by devices. Single item measures performed more poorly than multi-item questionnaires, EMAs and logs/diaries. On average, when compared to inclinometers, multi-item questionnaires, EMAs and logs/diaries were not significantly different, but had substantial amount of variability (up to 6 hours/day within individual studies) with approximately half over-reporting and half under-reporting. A total of 54 studies provided an assessment of reliability of a self-report measure, on average the reliability was good (ICC = 0.66). Conclusions: Evidence from this review suggests that single-item self-report measures generally underestimate sedentary time when compared to device measures. For accuracy, multi-item questionnaires, EMAs and logs/diaries with a shorter recall period should be encouraged above single item questions and longer recall periods if sedentary time is a primary outcome of study. Users should also be aware of the high degree of variability between and within tools. Studies should exert caution when comparing associations between different self-report and device measures with health outcomes. Systematic review registration: PROSPERO CRD4201911875

    Basics of Radiation Biology When Treating Hyperproliferative Benign Diseases

    Get PDF
    For decades, low- and moderate-dose radiation therapy (RT) has been shown to exert a beneficial therapeutic effect in a multitude of non-malignant conditions including painful degenerative muscoloskeletal and hyperproliferative disorders. Dupuytren and Ledderhose diseases are benign fibroproliferative diseases of the hand/foot with fibrotic nodules and fascial cords, which determine debilitating contractures and deformities of fingers/toes, while keloids are exuberant scar formations following burn damage, surgery, and trauma. Although RT has become an established and effective option in the management of these diseases, experimental studies to illustrate cellular composites and factors involved remain to be elucidated. More recent findings, however, indicate the involvement of radiation-sensitive targets like mitotic fibroblasts/myofibroblasts as well as inflammatory cells. Radiation-related molecular mechanisms affecting these target cells include the production of free radicals to hamper proliferative activity and interference with growth factors and cytokines. Moreover, an impairment of activated immune cells involved in both myofibroblast proliferative and inflammatory processes may further contribute to the clinical effects. We here aim at briefly describing mechanisms contributing to a modulation of proliferative and inflammatory processes and to summarize current concepts of treating hyperproliferative diseases by low and moderate doses of ionizing radiation

    The Maunakea Spectroscopic Explorer Book 2018

    Full text link
    (Abridged) This is the Maunakea Spectroscopic Explorer 2018 book. It is intended as a concise reference guide to all aspects of the scientific and technical design of MSE, for the international astronomy and engineering communities, and related agencies. The current version is a status report of MSE's science goals and their practical implementation, following the System Conceptual Design Review, held in January 2018. MSE is a planned 10-m class, wide-field, optical and near-infrared facility, designed to enable transformative science, while filling a critical missing gap in the emerging international network of large-scale astronomical facilities. MSE is completely dedicated to multi-object spectroscopy of samples of between thousands and millions of astrophysical objects. It will lead the world in this arena, due to its unique design capabilities: it will boast a large (11.25 m) aperture and wide (1.52 sq. degree) field of view; it will have the capabilities to observe at a wide range of spectral resolutions, from R2500 to R40,000, with massive multiplexing (4332 spectra per exposure, with all spectral resolutions available at all times), and an on-target observing efficiency of more than 80%. MSE will unveil the composition and dynamics of the faint Universe and is designed to excel at precision studies of faint astrophysical phenomena. It will also provide critical follow-up for multi-wavelength imaging surveys, such as those of the Large Synoptic Survey Telescope, Gaia, Euclid, the Wide Field Infrared Survey Telescope, the Square Kilometre Array, and the Next Generation Very Large Array.Comment: 5 chapters, 160 pages, 107 figure
    corecore