97 research outputs found

    Tensile bond strength and SEM analysis of enamel etched with Er:YAG laser and phosphoric acid: a comparative study In vitro

    Get PDF
    Er:YAG laser has been studied as a potential tool for restorative dentistry due to its ability to selectively remove oral hard tissue with minimal or no thermal damage to the surrounding tissues. The purpose of this study was to evaluate in vitro the tensile bond strength (TBS) of an adhesive/composite resin system to human enamel surfaces treated with 37% phosphoric acid, Er:YAG laser (lambda=2.94 mum) with a total energy of 16 J (80 mJ/pulse, 2Hz, 200 pulses, 250 ms pulse width), and Er:YAG laser followed by phosphoric acid etching. Analysis of the treated surfaces was performed by scanning electron microscopy (SEM) to assess morphological differences among the groups. TBS means (in MPa) were as follows: Er:YAG laser + acid (11.7 MPa) > acid (8.2 MPa) > Er:YAG laser (6.1 MPa), with the group treated with laser+acid being significantly from the other groups (p=0.0006 and p= 0.00019, respectively). The groups treated with acid alone and laser alone were significantly different from each other (p=0.0003). The SEM analysis revealed morphological changes that corroborate the TBS results, suggesting that the differences in TBS means among the groups are related to the different etching patterns produced by each type of surface treatment. The findings of this study indicate that the association between Er:YAG laser and phosphoric acid can be used as a valuable resource to increase bond strength to laser-prepared enamel.A tecnologia a laser tem sido estudada como uma ferramenta potencial para uso em odontologia devido à sua habilidade em remover tecido ósseo com um mínimo ou nenhum dano aos tecidos vizinhos. O objetivo deste estudo é comparar in vitro a resistência à tração do sistema adesivo em esmalte tratado com ácido fosfórico a 37 %, laser Er:YAG (lambda=2,94 mim) com energia total de 16 J (80 mJ/pulso, 2 Hz, 200 pulsos e largura de pulso de 250 ms) e com a combinação laser Er:YAG seguido por ácido fosfórico. O teste de resistência à tração foi usado para comparar a resistência à tração em cada grupo. Foi também realizada microscopia eletrônica de varredura para permitir a análise das diferenças morfológicas entre os grupos. Foram obtidos os seguintes valores médios de resistência para os grupos tratados com: laser (6,1 MPa), ácido fosfórico (8,2 MPa) e laser mais ácido (11,7 Mpa). Amostras tratadas com laser e ácido apresentaram valores maiores de resistência do que amostras com laser ou ácido isoladamente. A análise da microscopia eletrônica revelou diferenças que corroboram os resultados, demonstrando que diferenças de resistência entre os grupos são devidas às diferenças entre os padrões superficiais resultantes. Nossos resultados sugerem que a combinação do laser Er:YAG com ácido fosfórico pode ser usada como um método para aumentar a resistência à tração do sistema esmalte resina

    123I-MIBG cardiac uptake and smell identification in parkinsonian patients with LRRK2 mutations

    Get PDF
    Reduced uptake of 123I- metaiodobenzylguanidine (MIBG) on cardiac gammagraphy and impaired odor identification are markers of neurodegenerative diseases with Lewy bodies (LB) as a pathological hallmark, such as idiopathic Parkinson’s disease (IPD). LRRK2 patients present with a clinical syndrome indistinguishable from IPD, but LB have not been found in some cases. Patients with such mutations could behave differently than patients with IPD with respect to MIBG cardiac uptake and olfaction. We studied 14 LRRK2 patients, 14 IPD patients matched by age, gender, disease duration and severity, and 13 age and gender matched control subjects. Olfaction was analyzed through the University of Pennsylvania Smell Identification Test (UPSIT). MIBG cardiac uptake was evaluated through the H/M ratio. The late H/M was 1.44 ± 0.31 for LRRK2 patients, 1.19 ± 0.15 for PD patients, and 1.67 ± 0.16 for control subjects. LRRK2 patients presented lower but not statistically significant MIBG cardiac uptake than controls (p = 0.08) and significant higher uptake than PD patients (p = 0.04). UPSIT mean scores were 21.5 ± 7.3 for LRRK2 patients, 18.7 ± 6.2 for IPD patients and 29.7 ± 5.7 for control subjects. UPSIT score was lower in both LRRK2 and PD than in controls. In LRRK2 patients a positive correlation was found between myocardial MIBG uptake and UPSIT scores, (R = 0.801, p < 0.001). In LRRK2 patients, MIBG cardiac uptake was less impaired than in PD; a positive correlation between MIBG cardiac uptake and UPSIT scores was observed. As MIBG cardiac reduced uptake and impaired odor identification are markers of LB pathology, this findings may represent neuropathological heterogeneity among LRRK2 patients

    Nonmotor Symptoms in LRRK2 G2019S Associated Parkinson's Disease

    Get PDF
    BACKGROUND: Idiopathic Parkinson's disease (IPD) and LRRK2-associated PD (LRRK2-PD) might be expected to differ clinically since the neuropathological substrate of LRRK2-PD is heterogeneous. The range and severity of extra-nigral nonmotor features associated with LRRK2 mutations is also not well-defined. OBJECTIVE: To evaluate the prevalence and time of onset of nonmotor symptoms (NMS) in LRRK2-PD patients. METHODS: The presence of hyposmia and of neuropsychiatric, dysautonomic and sleep disturbances was assessed in 33 LRRK2-G2019S-PD patients by standardized questionnaires and validated scales. Thirty-three IPD patients, matched for age, gender, duration of parkinsonism and disease severity and 33 healthy subjects were also evaluated. RESULTS: University of Pennsylvania Smell Identification Test (UPSIT) scores in LRRK2-G2019S-PD were higher than those in IPD (23.5±6.8 vs 18.4±6.0; p = 0.002), and hyposmia was less frequent in G2019S carriers than in IPD (39.4% vs 75.8%; p = 0.01). UPSIT scores were significantly higher in females than in males in LRRK2-PD patients (26.9±4.7 vs 19.4±6.8; p<0.01). The frequency of sleep and neuropsychiatric disturbances and of dysautonomic symptoms in LRRK2-G2019S-PD was not significantly different from that in IPD. Hyposmia, depression, constipation and excessive daytime sleepiness, were reported to occur before the onset of classical motor symptoms in more than 40% of LRRK2-PD patients in whom these symptoms were present at the time of examination. CONCLUSION: Neuropsychiatric, dysautonomic and sleep disturbances occur as frequently in patients with LRRK2-G2019S-PD as in IPD but smell loss was less frequent in LRRK2-PD. Like in IPD, disturbances such as hyposmia, depression, constipation and excessive daytime sleepiness may antedate the onset of classical motor symptoms in LRRK2-G2019S-PD

    THEMIS: A Parameter Estimation Framework for the Event Horizon Telescope

    Get PDF
    The Event Horizon Telescope (EHT) provides the unprecedented ability to directly resolve the structure and dynamics of black hole emission regions on scales smaller than their horizons. This has the potential to critically probe the mechanisms by which black holes accrete and launch outflows, and the structure of supermassive black hole spacetimes. However, accessing this information is a formidable analysis challenge for two reasons. First, the EHT natively produces a variety of data types that encode information about the image structure in nontrivial ways; these are subject to a variety of systematic effects associated with very long baseline interferometry and are supplemented by a wide variety of auxiliary data on the primary EHT targets from decades of other observations. Second, models of the emission regions and their interaction with the black hole are complex, highly uncertain, and computationally expensive to construct. As a result, the scientific utilization of EHT observations requires a flexible, extensible, and powerful analysis framework. We present such a framework, Themis, which defines a set of interfaces between models, data, and sampling algorithms that facilitates future development. We describe the design and currently existing components of Themis, how Themis has been validated thus far, and present additional analyses made possible by Themis that illustrate its capabilities. Importantly, we demonstrate that Themis is able to reproduce prior EHT analyses, extend these, and do so in a computationally efficient manner that can efficiently exploit modern high-performance computing facilities. Themis has already been used extensively in the scientific analysis and interpretation of the first EHT observations of M87

    SYMBA: An end-to-end VLBI synthetic data generation pipeline: Simulating Event Horizon Telescope observations of M 87

    Get PDF
    Context. Realistic synthetic observations of theoretical source models are essential for our understanding of real observational data. In using synthetic data, one can verify the extent to which source parameters can be recovered and evaluate how various data corruption effects can be calibrated. These studies are the most important when proposing observations of new sources, in the characterization of the capabilities of new or upgraded instruments, and when verifying model-based theoretical predictions in a direct comparison with observational data. Aims. We present the SYnthetic Measurement creator for long Baseline Arrays (SYMBA), a novel synthetic data generation pipeline for Very Long Baseline Interferometry (VLBI) observations. SYMBA takes into account several realistic atmospheric, instrumental, and calibration effects. Methods. We used SYMBA to create synthetic observations for the Event Horizon Telescope (EHT), a millimetre VLBI array, which has recently captured the first image of a black hole shadow. After testing SYMBA with simple source and corruption models, we study the importance of including all corruption and calibration effects, compared to the addition of thermal noise only. Using synthetic data based on two example general relativistic magnetohydrodynamics (GRMHD) model images of M 87, we performed case studies to assess the image quality that can be obtained with the current and future EHT array for different weather conditions. Results. Our synthetic observations show that the effects of atmospheric and instrumental corruptions on the measured visibilities are significant. Despite these effects, we demonstrate how the overall structure of our GRMHD source models can be recovered robustly with the EHT2017 array after performing calibration steps, which include fringe fitting, a priori amplitude and network calibration, and self-calibration. With the planned addition of new stations to the EHT array in the coming years, images could be reconstructed with higher angular resolution and dynamic range. In our case study, these improvements allowed for a distinction between a thermal and a non-thermal GRMHD model based on salient features in reconstructed images

    Monitoring the Morphology of M87* in 2009–2017 with the Event Horizon Telescope

    Get PDF
    The Event Horizon Telescope (EHT) has recently delivered the first resolved images of M87*, the supermassive black hole in the center of the M87 galaxy. These images were produced using 230 GHz observations performed in 2017 April. Additional observations are required to investigate the persistence of the primary image feature—a ring with azimuthal brightness asymmetry—and to quantify the image variability on event horizon scales. To address this need, we analyze M87* data collected with prototype EHT arrays in 2009, 2011, 2012, and 2013. While these observations do not contain enough information to produce images, they are sufficient to constrain simple geometric models. We develop a modeling approach based on the framework utilized for the 2017 EHT data analysis and validate our procedures using synthetic data. Applying the same approach to the observational data sets, we find the M87* morphology in 2009–2017 to be consistent with a persistent asymmetric ring of ~40 μas diameter. The position angle of the peak intensity varies in time. In particular, we find a significant difference between the position angle measured in 2013 and 2017. These variations are in broad agreement with predictions of a subset of general relativistic magnetohydrodynamic simulations. We show that quantifying the variability across multiple observational epochs has the potential to constrain the physical properties of the source, such as the accretion state or the black hole spin

    First M87 Event Horizon Telescope Results. VI. The Shadow and Mass of the Central Black Hole

    Get PDF
    We present measurements of the properties of the central radio source in M87 using Event Horizon Telescope data obtained during the 2017 campaign. We develop and fit geometric crescent models (asymmetric rings with interior brightness depressions) using two independent sampling algorithms that consider distinct representations of the visibility data. We show that the crescent family of models is statistically preferred over other comparably complex geometric models that we explore. We calibrate the geometric model parameters using general relativistic magnetohydrodynamic (GRMHD) models of the emission region and estimate physical properties of the source. We further fit images generated from GRMHD models directly to the data. We compare the derived emission region and black hole parameters from these analyses with those recovered from reconstructed images. There is a remarkable consistency among all methods and data sets. We find that >50% of the total flux at arcsecond scales comes from near the horizon, and that the emission is dramatically suppressed interior to this region by a factor >10, providing direct evidence of the predicted shadow of a black hole. Across all methods, we measure a crescent diameter of 42 +/- 3 mu as and constrain its fractional width to b
    corecore