104 research outputs found

    Accelerator development in India

    Get PDF
    Accelerator development in India is reviewed with special emphasis on indigenous effort. It started with the 4 MeV cyclotron at the Saha Institute of Nuclear Physics, grew substantially with the installation of the Van de Graaff accelerators at Trombay and really came of age with the 224 cm Variable Energy Cyclotron at Calcutta, which resulted in considerable fall-out of technology. Simultaneously electron linac development has also taken place. Thus the stage is set for developing new types of accelerators such as the electron storage ring synchroton, and a proton/heavy ion synchrotron

    Measurement and analysis of alpha-induced reactions on Ta, Ag and Co

    Get PDF
    Excitation functions for the reaction 181Ta (α, xn)185-x Re,107,109Ag (α, ypxn) and 59Co (α, ypxn) were obtained from measurements of residual activity of stacked foils from threshold to 60 MeV. The excitation functions for the production of 181Re,182Re,183Re,184Re,105Ag, 111In,54Mn,56Co,58Co, and 60Co, are being presented. The experimental data are compared with calculations considering equilibrium as well as pre-equilibrium reactions according to the hybrid model of Blann. High energy part of the excitation functions is dominated by the pre-equilibrium reaction mechanism. Calculations were done using a priori calculational method of Overlaid Alice Code of Blann. Most of the excitation functions in the energy range mentioned above could be very well fitted with the hybrid model calculation for exciton number n=4 withn p=2 and n n=2. The overall agreement with theory is good. Certain discrepancies, however, indicate the necessity to revise the hybrid model with respect to emission of complex particles

    Fabrication of lithium-drifted silicon detectors by constant temperature method

    Get PDF
    A new approach for lithium drifting in silicon is described where the silicon devices under drift are held at constant temperature and bias at normal air ambient, and the drift process is terminated at the end of an estimated time depending upon the thickness of wafers. A 4-channel lithium drifting unit with electronically controlled oven has been constructed for this purpose. Full details of the fabrication procedure are given. A sizable number of Si(Li) detectors have been fabricated using this approach. The quality of the detectors is tested with 241Am alphas and conversion electrons from 209Bi and 137Cs sources. The detectors are regularly used for nuclear physics experiments at this Centre

    A pilot study of respiratory rate derived from a wearable biosensor compared with capnography in emergency department patients

    Get PDF
    © 2019 Li et al. Purpose: Respiratory rate is assessed less frequently than other vital signs, and documented respiratory rates are often erroneous. This pilot study compared respiratory rates derived from a wearable biosensor to those derived from capnography. Methods: Emergency department patients with respiratory complaints were enrolled and had capnography via nasal cannula and a wireless, wearable biosensor from Philips applied for approximately one hour. Respiratory rates were obtained from both of these methods. We determined the difference between median respiratory rates obtained from the biosensor and capnography and the proportion of biosensor-derived respiratory rates that were within three breaths/minute of the capnography-derived respiratory rates for each patient. A Spearman correlation coefficient was calculated to assess the strength of the correlation between mean respiratory rates derived from both methods. Plots of minute-by-minute respiratory rates, per patient, for each monitoring method were shown to two physicians. The physicians identified time periods in which the respiratory rates appeared invalid. The proportion of time with invalid respiratory rates for each patient, for each method, was calculated and averaged. Results: We analyzed data for 17 patients. Median biosensor-derived respiratory rate was 20 breaths/minute (range: 7-40 breaths/minute) and median capnography-derived respiratory rate was 25 breaths/minute (range: 0-58 breaths/minute). Overall, 72.8% of biosensorderived respiratory rates were within three breaths per minute of the capnography-derived respiratory rates. Overall mean difference was 3.5 breaths/minute (±5.2 breaths/minute). Respiratory rates appeared invalid 0.7% of the time for the biosensor and 5.0% of the time for capnography. Conclusion: Our pilot study suggests that the Philips wearable biosensor can continuously obtain respiratory rates that are comparable to capnography-derived respiratory rates among emergency department patients with respiratory complaints

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Pain distress : the negative emotion associated with procedures in ICU patients

    Get PDF
    The intensity of procedural pain in intensive care unit (ICU) patients is well documented. However, little is known about procedural pain distress, the psychological response to pain. Post hoc analysis of a multicenter, multinational study of procedural pain. Pain distress was measured before and during procedures (0-10 numeric rating scale). Factors that influenced procedural pain distress were identified by multivariable analyses using a hierarchical model with ICU and country as random effects. A total of 4812 procedures were recorded (3851 patients, 192 ICUs, 28 countries). Pain distress scores were highest for endotracheal suctioning (ETS) and tracheal suctioning, chest tube removal (CTR), and wound drain removal (median [IQRs] = 4 [1.6, 1.7]). Significant relative risks (RR) for a higher degree of pain distress included certain procedures: turning (RR = 1.18), ETS (RR = 1.45), tracheal suctioning (RR = 1.38), CTR (RR = 1.39), wound drain removal (RR = 1.56), and arterial line insertion (RR = 1.41); certain pain behaviors (RR = 1.19-1.28); pre-procedural pain intensity (RR = 1.15); and use of opioids (RR = 1.15-1.22). Patient-related variables that significantly increased the odds of patients having higher procedural pain distress than pain intensity were pre-procedural pain intensity (odds ratio [OR] = 1.05); pre-hospital anxiety (OR = 1.76); receiving pethidine/meperidine (OR = 4.11); or receiving haloperidol (OR = 1.77) prior to the procedure. Procedural pain has both sensory and emotional dimensions. We found that, although procedural pain intensity (the sensory dimension) and distress (the emotional dimension) may closely covary, there are certain factors than can preferentially influence each of the dimensions. Clinicians are encouraged to appreciate the multidimensionality of pain when they perform procedures and use this knowledge to minimize the patient's pain experience.Peer reviewe

    An international prospective study of INICC analyzing the incidence and risk factors for catheter-associated urinary tract infections in 235 ICUs across 8 Asian Countries

    Get PDF
    Background: Identify urinary catheter (UC)-associated urinary tract infections (CAUTI) incidence and risk factors (RF) in 235 ICUs in 8 Asian countries: India, Malaysia, Mongolia, Nepal, Pakistan, the Philippines, Thailand, and Vietnam. Methods: From January 1, 2014, to February 12, 2022, we conducted a prospective cohort study. To estimate CAUTI incidence, the number of UC days was the denominator, and CAUTI was the numerator. To estimate CAUTI RFs, we analyzed 11 variables using multiple logistic regression. Results: 84,920 patients hospitalized for 499,272 patient days acquired 869 CAUTIs. The pooled CAUTI rate per 1,000 UC-days was 3.08; for those using suprapubic-catheters (4.11); indwelling-catheters (2.65); trauma-ICU (10.55), neurologic-ICU (7.17), neurosurgical-ICU (5.28); in lower- middle-income countries (3.05); in upper-middle-income countries (1.71); at public-hospitals (5.98), at private-hospitals (3.09), at teaching-hospitals (2.04). The following variables were identified as CAUTI RFs: Age (adjusted odds ratio [aOR] = 1.01; 95% CI = 1.01-1.02; P < .0001); female sex (aOR = 1.39; 95% CI = 1.21-1.59; P < .0001); using suprapubic-catheter (aOR = 4.72; 95% CI = 1.69-13.21; P < .0001); length of stay before CAUTI acquisition (aOR = 1.04; 95% CI = 1.04-1.05; P < .0001); UC and device utilization-ratio (aOR = 1.07; 95% CI = 1.01-1.13; P = .02); hospitalized at trauma-ICU (aOR = 14.12; 95% CI = 4.68-42.67; P < .0001), neurologic-ICU (aOR = 14.13; 95% CI = 6.63-30.11; P < .0001), neurosurgical-ICU (aOR = 13.79; 95% CI = 6.88-27.64; P < .0001); public-facilities (aOR = 3.23; 95% CI = 2.34-4.46; P < .0001). Discussion: CAUTI rate and risk are higher for older patients, women, hospitalized at trauma-ICU, neurologic-ICU, neurosurgical-ICU, and public facilities. All of them are unlikely to change. Conclusions: It is suggested to focus on reducing the length of stay and the Urinary catheter device utilization ratio, avoiding suprapubic catheters, and implementing evidence-based CAUTI prevention recommendations

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved
    corecore