192 research outputs found

    Benefits of repetitive transcranial magnetic stimulation (rTMS) for spastic subjects : clinical, functional and biomechanical parameters for lower limb and walking in five hemiparetic patients

    Get PDF
    Introduction. Spasticity is a disabling symptom resulting from reorganization of spinal reflexes no longer inhibited by supraspinal control. Several studies have demonstrated interest in repetitive transcranial magnetic stimulation in spastic patients. We conducted a prospective, randomized, double-blind crossover study on five spastic hemiparetic patients to determine whether this type of stimulation of the premotor cortex can provide a clinical benefit. Material and Methods. Two stimulation frequencies (1 Hz and 10 Hz) were tested versus placebo. Patients were assessed clinically, by quantitative analysis of walking and measurement of neuromechanical parameters (H and T reflexes, musculoarticular stiffness of the ankle). Results. No change was observed after placebo and 10 Hz protocols. Clinical parameters were not significantly modified after 1 Hz stimulation, apart from a tendency towards improved recruitment of antagonist muscles on the Fügl-Meyer scale. Only cadence and recurvatum were significantly modified on quantitative analysis of walking. Neuromechanical parameters were modified with significant decreases in Hmax / Mmaxand T/Mmax ratios and stiffness indices 9 days or 31 days after initiation of TMS. Conclusion. This preliminary study supports the efficacy of low-frequency TMS to reduce reflex excitability and stiffness of ankle plantar flexors, while clinical signs of spasticity were not significantly modified

    European Stroke Organisation (ESO) Guidelines on Management of Unruptured Intracranial Aneurysms

    Get PDF
    Unruptured intracranial aneurysms (UIA) occur in around 3% of the population. Important management questions concern if and how to perform preventive UIA occlusion; if, how and when to perform follow up imaging and non-interventional means to reduce the risk of rupture. Using the Standard Operational Procedure of ESO we prepared guidelines according to GRADE methodology. Since no completed randomised trials exist, we used interim analyses of trials, and meta-analyses of observational and case-control studies to provide recommendations to guide UIA management. All recommendations were based on very low evidence. We suggest preventive occlusion if the estimated 5-year rupture risk exceeds the risk of preventive treatment. In general, we cannot recommend endovascular over microsurgical treatment, but suggest flow diverting stents as option only when there are no other low-risk options for UIA repair. To detect UIA recurrence we suggest radiological follow up after occlusion. In patients who are initially observed, we suggest radiological monitoring to detect future UIA growth, smoking cessation, treatment of hypertension, but not treatment with statins or acetylsalicylic acid with the indication to reduce the risk of aneurysm rupture. Additionally, we formulated 15 expert-consensus statements. All experts suggest to assess UIA patients within a multidisciplinary setting (neurosurgery, neuroradiology and neurology) at centres consulting >100 UIA patients per year, to use a shared decision-making process based on the team recommendation and patient preferences, and to repair UIA only in centres performing the proposed treatment in >30 patients with (ruptured or unruptured) aneurysms per year per neurosurgeon or neurointerventionalist. These UIA guidelines provide contemporary recommendations and consensus statement on important aspects of UIA management until more robust data come available.info:eu-repo/semantics/publishedVersio

    Intracranial Aneurysm Classifier Using Phenotypic Factors: An International Pooled Analysis

    Get PDF
    Intracranial aneurysms (IAs) are usually asymptomatic with a low risk of rupture, but consequences of aneurysmal subarachnoid hemorrhage (aSAH) are severe. Identifying IAs at risk of rupture has important clinical and socio-economic consequences. The goal of this study was to assess the effect of patient and IA characteristics on the likelihood of IA being diagnosed incidentally versus ruptured. Patients were recruited at 21 international centers. Seven phenotypic patient characteristics and three IA characteristics were recorded. The analyzed cohort included 7992 patients. Multivariate analysis demonstrated that: (1) IA location is the strongest factor associated with IA rupture status at diagnosis; (2) Risk factor awareness (hypertension, smoking) increases the likelihood of being diagnosed with unruptured IA; (3) Patients with ruptured IAs in high-risk locations tend to be older, and their IAs are smaller; (4) Smokers with ruptured IAs tend to be younger, and their IAs are larger; (5) Female patients with ruptured IAs tend to be older, and their IAs are smaller; (6) IA size and age at rupture correlate. The assessment of associations regarding patient and IA characteristics with IA rupture allows us to refine IA disease models and provide data to develop risk instruments for clinicians to support personalized decision-making

    Imaging features and safety and efficacy of endovascular stroke treatment: a meta-analysis of individual patient-level data

    Get PDF
    Background: Evidence regarding whether imaging can be used effectively to select patients for endovascular thrombectomy (EVT) is scarce. We aimed to investigate the association between baseline imaging features and safety and efficacy of EVT in acute ischaemic stroke caused by anterior large-vessel occlusion. Methods: In this meta-analysis of individual patient-level data, the HERMES collaboration identified in PubMed seven randomised trials in endovascular stroke that compared EVT with standard medical therapy, published between Jan 1, 2010, and Oct 31, 2017. Only trials that required vessel imaging to identify patients with proximal anterior circulation ischaemic stroke and that used predominantly stent retrievers or second-generation neurothrombectomy devices in the EVT group were included. Risk of bias was assessed with the Cochrane handbook methodology. Central investigators, masked to clinical information other than stroke side, categorised baseline imaging features of ischaemic change with the Alberta Stroke Program Early CT Score (ASPECTS) or according to involvement of more than 33% of middle cerebral artery territory, and by thrombus volume, hyperdensity, and collateral status. The primary endpoint was neurological functional disability scored on the modified Rankin Scale (mRS) score at 90 days after randomisation. Safety outcomes included symptomatic intracranial haemorrhage, parenchymal haematoma type 2 within 5 days of randomisation, and mortality within 90 days. For the primary analysis, we used mixed-methods ordinal logistic regression adjusted for age, sex, National Institutes of Health Stroke Scale score at admission, intravenous alteplase, and time from onset to randomisation, and we used interaction terms to test whether imaging categorisation at baseline modifies the association between treatment and outcome. This meta-analysis was prospectively designed by the HERMES executive committee but has not been registered. Findings: Among 1764 pooled patients, 871 were allocated to the EVT group and 893 to the control group. Risk of bias was low except in the THRACE study, which used unblinded assessment of outcomes 90 days after randomisation and MRI predominantly as the primary baseline imaging tool. The overall treatment effect favoured EVT (adjusted common odds ratio [cOR] for a shift towards better outcome on the mRS 2·00, 95% CI 1·69–2·38; p<0·0001). EVT achieved better outcomes at 90 days than standard medical therapy alone across a broad range of baseline imaging categories. Mortality at 90 days (14·7% vs 17·3%, p=0·15), symptomatic intracranial haemorrhage (3·8% vs 3·5%, p=0·90), and parenchymal haematoma type 2 (5·6% vs 4·8%, p=0·52) did not differ between the EVT and control groups. No treatment effect modification by baseline imaging features was noted for mortality at 90 days and parenchymal haematoma type 2. Among patients with ASPECTS 0–4, symptomatic intracranial haemorrhage was seen in ten (19%) of 52 patients in the EVT group versus three (5%) of 66 patients in the control group (adjusted cOR 3·94, 95% CI 0·94–16·49; pinteraction=0·025), and among patients with more than 33% involvement of middle cerebral artery territory, symptomatic intracranial haemorrhage was observed in 15 (14%) of 108 patients in the EVT group versus four (4%) of 113 patients in the control group (4·17, 1·30–13·44, pinteraction=0·012). Interpretation: EVT achieves better outcomes at 90 days than standard medical therapy across a broad range of baseline imaging categories, including infarcts affecting more than 33% of middle cerebral artery territory or ASPECTS less than 6, although in these patients the risk of symptomatic intracranial haemorrhage was higher in the EVT group than the control group. This analysis provides preliminary evidence for potential use of EVT in patients with large infarcts at baseline. Funding: Medtronic

    Materials for Diabetes Therapeutics

    Get PDF
    This review is focused on the materials and methods used to fabricate closed-loop systems for type 1 diabetes therapy. Herein, we give a brief overview of current methods used for patient care and discuss two types of possible treatments and the materials used for these therapies–(i) artificial pancreases, comprised of insulin producing cells embedded in a polymeric biomaterial, and (ii) totally synthetic pancreases formulated by integrating continuous glucose monitors with controlled insulin release through degradable polymers and glucose-responsive polymer systems. Both the artificial and the completely synthetic pancreas have two major design requirements: the device must be both biocompatible and be permeable to small molecules and proteins, such as insulin. Several polymers and fabrication methods of artificial pancreases are discussed: microencapsulation, conformal coatings, and planar sheets. We also review the two components of a completely synthetic pancreas. Several types of glucose sensing systems (including materials used for electrochemical, optical, and chemical sensing platforms) are discussed, in addition to various polymer-based release systems (including ethylene-vinyl acetate, polyanhydrides, and phenylboronic acid containing hydrogels).Juvenile Diabetes Research Foundation International (17-2007-1063)Leona M. and Harry B. Helmsley Charitable Trust (09PG-T1D027)United States. National Institutes of Health (F32 EB011580-01
    • …
    corecore