5 research outputs found
A FABRY-PEROT CAVITY FOR COMPTON POLARIMETRY
A new kind of Compton polarimeter using a resonant Fabry—Pe« rot cavity as a power buildup for the photon beam is proposed. A prototype of such a cavity is described, along with the results obtained in terms of source to be used in a Compton scattering polarimeter. ( 1998 Elsevier Science B.V. All rights reserved
Neutrons from multiplicity-selected La-La and Nb-Nb collisions at 400A MeV and La-La collisions at 250A MeV
Triple-differential cross sections for neutrons from high-multiplicity La-La
collisions at 250 and 400 MeV per nucleon and Nb-Nb collisions at 400 MeV per
nucleon were measured at several polar angles as a function of the azimuthal
angle with respect to the reaction plane of the collision. The reaction plane
was determined by a transverse-velocity method with the capability of
identifying charged-particles with Z=1, Z=2, and Z > 2. The flow of neutrons
was extracted from the slope at mid-rapidity of the curve of the average
in-plane momentum vs the center-of-mass rapidity. The squeeze-out of the
participant neutrons was observed in a direction normal to the reaction plane
in the normalized momentum coordinates in the center-of-mass system.
Experimental results of the neutron squeeze-out were compared with BUU
calculations. The polar-angle dependence of the maximum azimuthal anisotropy
ratio was found to be insensitive to the mass of the colliding
nuclei and the beam energy. Comparison of the observed polar-angle dependence
of the maximum azimuthal anisotropy ratio with BUU calculations for
free neutrons revealed that is insensitive also to the
incompressibility modulus in the nuclear equation of state.Comment: ReVTeX, 16 pages, 17 figures. To be published in Physical Review
Bulk micromegas detectors for large TPC applications
A large volume TPC will be used in the near future in a variety of experiments including T2K. The bulk Micromegas detector for this TPC is built using a novel production technique particularly suited for compact and robust low mass detectors. The capability to pave a large surface with a simple mounting solution and small dead space between modules is of particular interest for these applications. We have built several large bulk Micromegas detectors (27 x 26 cm2) and we have tested them in the former HARP field cage setup with a magnetic field. Cosmic ray data have been acquired in a variety of experimental conditions. Good detector performances and space point resolution have been achieved
Recommended from our members
A New Type of Compton Polarimeter for Jefferson Lab Hall A
In this paper, we present the principle and the studies for a new type of Compton polarimeter based on the use of power buildup Fabry-Perot cavity to get a 3% measurement of the Jefferson Lab electron polarization within minutes
Large underground, liquid based detectors for astro-particle physics in Europe: scientific case and prospects
This document reports on a series of experimental and theoretical studies
conducted to assess the astro-particle physics potential of three future
large-scale particle detectors proposed in Europe as next generation
underground observatories. The proposed apparatus employ three different and,
to some extent, complementary detection techniques: GLACIER (liquid Argon TPC),
LENA (liquid scintillator) and MEMPHYS (\WC), based on the use of large mass of
liquids as active detection media. The results of these studies are presented
along with a critical discussion of the performance attainable by the three
proposed approaches coupled to existing or planned underground laboratories, in
relation to open and outstanding physics issues such as the search for matter
instability, the detection of astrophysical- and geo-neutrinos and to the
possible use of these detectors in future high-intensity neutrino beams.Comment: 50 pages, 26 figure