275 research outputs found
Emergency Department visits due to intoxications in a Dutch university hospital: Occurrence, characteristics and health care costs
Background: Intoxications with alcohol and drugs are common in the Emergency Department. This study aimed to describe the occurrence and characteristics of intoxications (alcohol, Drugs of Abuse (DOA), pharmaceutical and chemical) presented to the Emergency Department and the health care costs of these intoxications. Methods: This was a retrospective medical record study of all patients (≥ 16 years) who presented to the Emergency Department of an inner-city academic hospital in the Netherlands due to single or multiple intoxication(s) as the primary or secondary reason in the year 2016. An intoxication was reported as present if the attending physician described the intoxication in the patient's medical record. Results: A total of 783 patients were included, accounting for 3.2% of the adult Emergency Department population (age ≥ 16 year). In 30% more than one substance was used. Intoxications with alcohol, Drugs of Abuse and pharmaceuticals was reported in respectively 62%, 29% and 21% of the intoxicated patients. The mean costs per patient presenting with an intoxication to the Emergency Department was € 1,490. The mean costs per patient were highest for pharmaceutical intoxications (€ 2,980), followed by Drugs of Abuse (€ 1,140) and alcohol (€ 1,070). Conclusions: Intoxications among patients aged 16 years and older are frequently seen at the Emergency Department and are frequently caused by multiple substances. Alcohol is the most common intoxication. Substantial healthcare costs are involved. Therefore, this study suggests that further research into hazardous alcohol consumption and DOA abuse is warranted. Copyright
Charged-Particle Probing of X-Ray-Driven Inertial-Fusion Implosions
International audienc
Efficient Recognition of Partially Visible Objects Using a Logarithmic Complexity Matching Technique
An important task in computer vision is the recognition of partially visible two-dimensional objects in a gray scale image. Recent works addressing this problem have attempted to match spatially local features from the image to features generated by models of the objects. However, many algo rithms are considerably less efficient than they might be, typ ically being O(IN) or worse, where I is the number offeatures in the image and N is the number of features in the model set. This is invariably due to the feature-matching portion of the algorithm. In this paper we discuss an algorithm that significantly improves the efficiency offeature matching. In addition, we show experimentally that our recognition algo rithm is accurate and robust. Our algorithm uses the local shape of contour segments near critical points, represented in slope angle-arclength space (θ-s space), as fundamental fea ture vectors. These feature vectors are further processed by projecting them onto a subspace in θ-s space that is obtained by applying the Karhunen-Loève expansion to all such fea tures in the set of models, yielding the final feature vectors. This allows the data needed to store the features to be re duced, while retaining nearly all information important for recognition. The heart of the algorithm is a technique for performing matching between the observed image features and the precomputed model features, which reduces the runtime complexity from O(IN) to O(I log I + I log N), where I and N are as above. The matching is performed using a tree data structure, called a kD tree, which enables multidi mensional searches to be performed in O(log) time.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66975/2/10.1177_027836498900800608.pd
Measurement of and charged current inclusive cross sections and their ratio with the T2K off-axis near detector
We report a measurement of cross section and the first measurements of the cross section
and their ratio
at (anti-)neutrino energies below 1.5
GeV. We determine the single momentum bin cross section measurements, averaged
over the T2K -flux, for the detector target material (mainly
Carbon, Oxygen, Hydrogen and Copper) with phase space restricted laboratory
frame kinematics of 500 MeV/c. The
results are and $\sigma(\nu)=\left( 2.41\
\pm0.022{\rm{(stat.)}}\pm0.231{\rm (syst.)}\ \right)\times10^{-39}^{2}R\left(\frac{\sigma(\bar{\nu})}{\sigma(\nu)}\right)=
0.373\pm0.012{\rm (stat.)}\pm0.015{\rm (syst.)}$.Comment: 18 pages, 8 figure
Search for Lorentz and CPT violation using sidereal time dependence of neutrino flavor transitions over a short baseline
A class of extensions of the Standard Model allows Lorentz and CPT violations, which can be identified
by the observation of sidereal modulations in the neutrino interaction rate. A search for such modulations
was performed using the T2K on-axis near detector. Two complementary methods were used in this study,
both of which resulted in no evidence of a signal. Limits on associated Lorentz and CPT-violating terms
from the Standard Model extension have been derived by taking into account their correlations in this
model for the first time. These results imply such symmetry violations are suppressed by a factor of more
than 10 20 at the GeV scale
A search for the decay
We search for the rare flavor-changing neutral-current decay in a data sample of 82 fb collected with the {\sl BABAR}
detector at the PEP-II B-factory. Signal events are selected by examining the
properties of the system recoiling against either a reconstructed hadronic or
semileptonic charged-B decay. Using these two independent samples we obtain a
combined limit of
at the 90% confidence level. In addition, by selecting for pions rather than
kaons, we obtain a limit of using only the hadronic B reconstruction method.Comment: 7 pages, 8 postscript figures, submitted to Phys. Rev. Let
High-reflectivity broadband distributed Bragg reflector lattice matched to ZnTe
We report on the realization of a high quality distributed Bragg reflector
with both high and low refractive index layers lattice matched to ZnTe. Our
structure is grown by molecular beam epitaxy and is based on binary compounds
only. The high refractive index layer is made of ZnTe, while the low index
material is made of a short period triple superlattice containing MgSe, MgTe,
and ZnTe. The high refractive index step of Delta_n=0.5 in the structure
results in a broad stopband and the reflectivity coefficient exceeding 99% for
only 15 Bragg pairs.Comment: 4 pages, 3 figure
EuFeAs under high pressure: an antiferromagnetic bulk superconductor
We report the ac magnetic susceptibility and resistivity
measurements of EuFeAs under high pressure . By observing nearly
100% superconducting shielding and zero resistivity at = 28 kbar, we
establish that -induced superconductivity occurs at ~30 K in
EuFeAs. shows an anomalous nearly linear temperature dependence
from room temperature down to at the same . indicates that
an antiferromagnetic order of Eu moments with ~20 K persists
in the superconducting phase. The temperature dependence of the upper critical
field is also determined.Comment: To appear in J. Phys. Soc. Jpn., Vol. 78 No.
- …