140 research outputs found

    Selective attention to sound features mediates cross-modal activation of visual cortices.

    Get PDF
    Contemporary schemas of brain organization now include multisensory processes both in low-level cortices as well as at early stages of stimulus processing. Evidence has also accumulated showing that unisensory stimulus processing can result in cross-modal effects. For example, task-irrelevant and lateralised sounds can activate visual cortices; a phenomenon referred to as the auditory-evoked contralateral occipital positivity (ACOP). Some claim this is an example of automatic attentional capture in visual cortices. Other results, however, indicate that context may play a determinant role. Here, we investigated whether selective attention to spatial features of sounds is a determining factor in eliciting the ACOP. We recorded high-density auditory evoked potentials (AEPs) while participants selectively attended and discriminated sounds according to four possible stimulus attributes: location, pitch, speaker identity or syllable. Sound acoustics were held constant, and their location was always equiprobable (50% left, 50% right). The only manipulation was to which sound dimension participants attended. We analysed the AEP data from healthy participants within an electrical neuroimaging framework. The presence of sound-elicited activations of visual cortices depended on the to-be-discriminated, goal-based dimension. The ACOP was elicited only when participants were required to discriminate sound location, but not when they attended to any of the non-spatial features. These results provide a further indication that the ACOP is not automatic. Moreover, our findings showcase the interplay between task-relevance and spatial (un)predictability in determining the presence of the cross-modal activation of visual cortices

    Discovery of a stellar companion to the nearby solar-analogue HD 104304

    Full text link
    Sun-like stars are promising candidates to host exoplanets and are often included in exoplanet surveys by radial velocity (RV) and direct imaging. In this paper we report on the detection of a stellar companion to the nearby solar-analogue star HD 104304, which previously was considered to host a planetary mass or brown dwarf companion. We searched for close stellar and substellar companions around extrasolar planet host stars with high angular resolution imaging to characterize planet formation environments. The detection of the stellar companion was achieved by high angular resolution measurements, using the "Lucky Imaging" technique at the ESO NTT 3.5m with the AstraLux Sur instrument. We combined the results with VLT/NACO archive data, where the companion could also be detected. The results were compared to precise RV measurements of HD 104304, obtained at the Lick and Keck observatories from 2001-2010. We confirmed common proper motion of the binary system. A spectral type of M4V of the companion and a mass of 0.21 M_Sun was derived. Due to comparison of the data with RV measurements of the unconfirmed planet candidate listed in the Extrasolar Planets Encyclopaedia, we suggest that the discovered companion is the origin of the RV trend and that the inclination of the orbit of approximately 35 degrees explains the relatively small RV signal.Comment: 4 pages, 4 PNG figures, use aa.cls, accepted for publication in Astronomy & Astrophysic

    Quantum Noise Locking

    Full text link
    Quantum optical states which have no coherent amplitude, such as squeezed vacuum states, can not rely on standard readout techniques to generate error signals for control of the quadrature phase. Here we investigate the use of asymmetry in the quadrature variances to obtain a phase-sensitive readout and to lock the phase of a squeezed vacuum state, a technique which we call noise locking (NL). We carry out a theoretical derivation of the NL error signal and the associated stability of the squeezed and anti-squeezed lock points. Experimental data for the NL technique both in the presence and absence of coherent fields are shown, including a comparison with coherent locking techniques. Finally, we use NL to enable a stable readout of the squeezed vacuum state on a homodyne detector.Comment: Accepted for publication in Journal of Optics:B special issue on Quantum Contro

    A Spitzer IRAC Imaging Survey for T Dwarf Companions Around M, L, and T Dwarfs: Observations, Results, and Monte Carlo Population Analyses

    Full text link
    We report observational techniques, results, and Monte Carlo population analyses from a Spitzer Infrared Array Camera imaging survey for substellar companions to 117 nearby M, L, and T dwarf systems (median distance of 10 pc, mass range of 0.6 to \sim0.05 M\odot). The two-epoch survey achieves typical detection sensitivities to substellar companions of [4.5 {\mu}m] \leq 17.2 mag for angular separations between about 7" and 165". Based on common proper motion analysis, we find no evidence for new substellar companions. Using Monte Carlo orbital simulations (assuming random inclination, random eccentricity, and random longitude of pericenter), we conclude that the observational sensitivities translate to an ability to detect 600-1100K brown dwarf companions at semimajor axes greater than ~35 AU, and to detect 500-600K companions at semimajor axes greater than ~60 AU. The simulations also estimate a 600-1100K T dwarf companion fraction of < 3.4% for 35-1200 AU separations, and < 12.4% for the 500-600K companions, for 60-1000 AU separations.Comment: 35 pages, 6 figure

    The upgrade of GEO600

    Get PDF
    The German / British gravitational wave detector GEO 600 is in the process of being upgraded. The upgrading process of GEO 600, called GEO-HF, will concentrate on the improvement of the sensitivity for high frequency signals and the demonstration of advanced technologies. In the years 2009 to 2011 the detector will undergo a series of upgrade steps, which are described in this paper.Comment: 9 pages, Amaldi 8 conference contributio

    Orbital effects of a monochromatic plane gravitational wave with ultra-low frequency incident on a gravitationally bound two-body system

    Full text link
    We analytically compute the long-term orbital variations of a test particle orbiting a central body acted upon by an incident monochromatic plane gravitational wave. We assume that the characteristic size of the perturbed two-body system is much smaller than the wavelength of the wave. Moreover, we also suppose that the wave's frequency is much smaller than the particle's orbital one. We make neither a priori assumptions about the direction of the wavevector nor on the orbital geometry of the planet. We find that, while the semi-major axis is left unaffected, the eccentricity, the inclination, the longitude of the ascending node, the longitude of pericenter and the mean anomaly undergo non-vanishing long-term changes. They are not secular trends because of the slow modulation introduced by the tidal matrix coefficients and by the orbital elements themselves. They could be useful to indepenedently constrain the ultra-low frequency waves which may have been indirectly detected in the BICEP2 experiment. Our calculation holds, in general, for any gravitationally bound two-body system whose characteristic frequency is much larger than the frequency of the external wave. It is also valid for a generic perturbation of tidal type with constant coefficients over timescales of the order of the orbital period of the perturbed particle.Comment: LaTex2e, 24 pages, no figures, no tables. Changes suggested by the referees include

    Auditory Cortical Detection and Discrimination Correlates with Communicative Significance

    Get PDF
    Plasticity studies suggest that behavioral relevance can change the cortical processing of trained or conditioned sensory stimuli. However, whether this occurs in the context of natural communication, where stimulus significance is acquired through social interaction, has not been well investigated, perhaps because neural responses to species-specific vocalizations can be difficult to interpret within a systematic framework. The ultrasonic communication system between isolated mouse pups and adult females that either do or do not recognize the calls' significance provides an opportunity to explore this issue. We applied an information-based analysis to multi- and single unit data collected from anesthetized mothers and pup-naïve females to quantify how the communicative significance of pup calls affects their encoding in the auditory cortex. The timing and magnitude of information that cortical responses convey (at a 2-ms resolution) for pup call detection and discrimination was significantly improved in mothers compared to naïve females, most likely because of changes in call frequency encoding. This was not the case for a non-natural sound ensemble outside the mouse vocalization repertoire. The results demonstrate that a sensory cortical change in the timing code for communication sounds is correlated with the vocalizations' behavioral relevance, potentially enhancing functional processing by improving its signal to noise ratio

    Feel it in my bones: Composing multimodal experience through tissue conduction

    Get PDF
    We outline here the feasibility of coherently utilising tissue conduction for spatial audio and tactile input. Tissue conduction display-specific compositional concerns are discussed; it is hypothesised that the qualia available through this medium substantively differ from those for conventional artificial means of appealing to auditory spatial perception. The implications include that spatial music experienced in this manner constitutes a new kind of experience, and that the ground rules of composition are yet to be established. We refer to results from listening experiences with one hundred listeners in an unstructured attribute elicitation exercise, where prominent themes such as “strange”, “weird”, “positive”, “spatial” and “vibrations” emerged. We speculate on future directions aimed at taking maximal advantage of the principle of multimodal perception to broaden the informational bandwidth of the display system. Some implications for composition for hearing-impaired are elucidated.n/

    Acoustic Cues for Sound Source Distance and Azimuth in Rabbits, a Racquetball and a Rigid Spherical Model

    Get PDF
    There are numerous studies measuring the transfer functions representing signal transformation between a source and each ear canal, i.e., the head-related transfer functions (HRTFs), for various species. However, only a handful of these address the effects of sound source distance on HRTFs. This is the first study of HRTFs in the rabbit where the emphasis is on the effects of sound source distance and azimuth on HRTFs. With the rabbit placed in an anechoic chamber, we made acoustic measurements with miniature microphones placed deep in each ear canal to a sound source at different positions (10–160 cm distance, ±150° azimuth). The sound was a logarithmically swept broadband chirp. For comparisons, we also obtained the HRTFs from a racquetball and a computational model for a rigid sphere. We found that (1) the spectral shape of the HRTF in each ear changed with sound source location; (2) interaural level difference (ILD) increased with decreasing distance and with increasing frequency. Furthermore, ILDs can be substantial even at low frequencies when distance is close; and (3) interaural time difference (ITD) decreased with decreasing distance and generally increased with decreasing frequency. The observations in the rabbit were reproduced, in general, by those in the racquetball, albeit greater in magnitude in the rabbit. In the sphere model, the results were partly similar and partly different than those in the racquetball and the rabbit. These findings refute the common notions that ILD is negligible at low frequencies and that ITD is constant across frequency. These misconceptions became evident when distance-dependent changes were examined

    Mechanical aspects in interferometric gravity wave detectors

    No full text
    In order to measure the tiny effects of gravitational waves, strains in space (i.e. relative changes in distance) of as little as 10-21 or even less have to be detected, at frequencies ranging from 10011z to several kHz. Large laser interferometers are the most promising approach to reach such extreme sensitivities. This lsquostraightforwardrsquo road is, however, obstructed by a multitude of effects that cause (or fake) such fluctuations in distance. Among these are seismic motions, thermal vibrations of optical components, pressure fluctuations of the residual gas in the vacuum tubes, and fundamental effects such as Heisenberg's uncertainty relation. What all of these noise sources have in common is that their effects can be reduced by the choice of sufficiently large arm lengths. This is what dictates the (very expensive) choice of arm lengths of 3 to 4 km in the currently proposed gravitational wave detectors (USA, D-GB, F-I, AUS, JAP)
    corecore