569 research outputs found

    Liver Enzymes: Interaction Analysis of Smoking with Alcohol Consumption or BMI, Comparing AST and ALT to γ-GT

    Get PDF
    A detrimental interaction between smoking and alcohol consumption with respect serum γ-glutamyltransferase (γ-GT) has recently been described. The underlying mechanisms remain unknown. The present work aimed to provide further insights by examining similar interactions pertaining to aspartate and alanine transaminase (AST, ALT), routine liver markers less prone to enzyme induction.<0.0001). The interactions all were in the same directions as for γ-GT, i.e. synergistic with alcohol and opposite with BMI.The patterns of interaction between smoking and alcohol consumption or BMI with respect to AST and ALT resembled those observed for γ-GT. This renders enzyme induction a less probable mechanism for these associations, whereas it might implicate exacerbated hepatocellular vulnerability and injury

    Differences in smoking associated DNA methylation patterns in South Asians and Europeans

    Get PDF
    This is a freely-available open access publication. Please cite the published version which is available via the DOI link in this record.Background DNA methylation is strongly associated with smoking status at multiple sites across the genome. Studies have largely been restricted to European origin individuals yet the greatest increase in smoking is occurring in low income countries, such as the Indian subcontinent. We determined whether there are differences between South Asians and Europeans in smoking related loci, and if a smoking score, combining all smoking related DNA methylation scores, could differentiate smokers from non-smokers. Results Illumina HM450k BeadChip arrays were performed on 192 samples from the Southall And Brent REvisited (SABRE) cohort. Differential methylation in smokers was identified in 29 individual CpG sites at 18 unique loci. Interaction between smoking status and ethnic group was identified at the AHRR locus. Ethnic differences in DNA methylation were identified in non-smokers at two further loci, 6p21.33 and GNG12. With the exception of GFI1 and MYO1G these differences were largely unaffected by adjustment for cell composition. A smoking score based on methylation profile was constructed. Current smokers were identified with 100% sensitivity and 97% specificity in Europeans and with 80% sensitivity and 95% specificity in South Asians. Conclusions Differences in ethnic groups were identified in both single CpG sites and combined smoking score. The smoking score is a valuable tool for identification of true current smoking behaviour. Explanations for ethnic differences in DNA methylation in association with smoking may provide valuable clues to disease pathways.Wellcome Trust Enhancement grantMedical Research CouncilDiabetes UKthe British Heart Foundatio

    FIVA:Functional Information Viewer and Analyzer extracting biological knowledge from transcriptome data of prokaryotes

    Get PDF
    FIVA (Function Information Viewer and Analyzer) aids researchers in the prokaryotic community to quickly identify relevant biological processes following transcriptome analysis. Our software assists in functional profiling of large sets of genes and generates a comprehensive overview of affected biological processes.

    A verification protocol for the probe sequences of Affymetrix genome arrays reveals high probe accuracy for studies in mouse, human and rat

    Get PDF
    BACKGROUND: The Affymetrix GeneChip technology uses multiple probes per gene to measure its expression level. Individual probe signals can vary widely, which hampers proper interpretation. This variation can be caused by probes that do not properly match their target gene or that match multiple genes. To determine the accuracy of Affymetrix arrays, we developed an extensive verification protocol, for mouse arrays incorporating the NCBI RefSeq, NCBI UniGene Unique, NIA Mouse Gene Index, and UCSC mouse genome databases. RESULTS: Applying this protocol to Affymetrix Mouse Genome arrays (the earlier U74Av2 and the newer 430 2.0 array), the number of sequence-verified probes with perfect matches was no less than 85% and 95%, respectively; and for 74% and 85% of the probe sets all probes were sequence verified. The latter percentages increased to 80% and 94% after discarding one or two unverifiable probes per probe set, and even further to 84% and 97% when, in addition, allowing for one or two mismatches between probe and target gene. Similar results were obtained for other mouse arrays, as well as for human and rat arrays. Based on these data, refined chip definition files for all arrays are provided online. Researchers can choose the version appropriate for their study to (re)analyze expression data. CONCLUSION: The accuracy of Affymetrix probe sequences is higher than previously reported, particularly on newer arrays. Yet, refined probe set definitions have clear effects on the detection of differentially expressed genes. We demonstrate that the interpretation of the results of Affymetrix arrays is improved when the new chip definition files are used

    Computational and Mathematical Modelling of the EGF Receptor System

    Get PDF
    This chapter gives an overview of computational and mathematical modelling of the EGF receptor system. It begins with a survey of motivations for producing such models, then describes the main approaches that are taken to carrying out such modelling, viz. differential equations and individual-based modelling. Finally, a number of projects that applying modelling and simulation techniques to various aspects of the EGF receptor system are described

    Status quo after one year of COVID-19 pandemic in otolaryngological hospital-based departments and private practices in Germany

    Get PDF
    PURPOSE: The COVID-19 pandemic has affected healthcare systems worldwide. Data on the impact on otolaryngological clinics and private practices is sparse. This study aimed to present data on healthcare worker (HCW) screening, status of HCW, pre-interventional testing, the use of personal protective equipment (PPE) and the economic impact of the pandemic. METHODS: Otolaryngological private practices and hospital-based departments were surveyed nationwide using an online questionnaire. Participating facilities were recruited via the German Society for Oto-Rhino-Laryngology and the German Association for Otolaryngologists in Bavaria. RESULTS: 365 private practices (2776 employees) and 65 hospitals (2333 employees) were included. Significantly more hospitals (68.7%) than practices (40.5%) performed pre-interventional testing in their outpatients (p < 0.00). Most inpatients were tested in practices and hospitals (100.0% and 95.0%; p = 0.08). HCW screening was performed in 73.7% of practices and in 77.3% of hospitals (p = 0.54). Significantly more HCW infections were reported in private practices (4.7%) than in hospital (3.6%; p = 0.03). The private or home environment was the most frequent source of infection among HCW in hospitals (44%) and practices (63%). The use of PPE increased over the course of the pandemic. The number of procedures and the revenue decreased in 2020. CONCLUSION: The rate of pre-interventional testing among outpatients in otolaryngological practices is low and HCW infections were found to be more frequent in practices than in hospitals. In addition, a high rate of infections in otolaryngological HCW seems to stem from the private or home environment. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00405-021-06992-2

    Observations of Mkn 421 in 2004 with H.E.S.S. at large zenith angles

    Get PDF
    Mkn 421 was observed during a high flux state for nine nights in April and May 2004 with the fully operational High Energy Stereoscopic System (H.E.S.S.) in Namibia. The observations were carried out at zenith angles of 60^\circ--65^\circ, which result in an average energy threshold of 1.5 TeV and a collection area reaching 2~km2^2 at 10~TeV. Roughly 7000 photons from Mkn~421 were accumulated with an average gamma-ray rate of 8 photons/min. The overall significance of the detection exceeds 100 standard deviations. The light-curve of integrated fluxes above 2~TeV shows changes of the diurnal flux up to a factor of 4.3. For nights of high flux, intra-night variability is detected with a decay time of less than 1 hour. The time averaged energy spectrum is curved and is well described by a power-law with a photon index \egamm and an exponential cutoff at \ecut~TeV and an average integral flux above 2~TeV of 3 Crab flux units. Significant variations of the spectral shape are detected with a spectral hardening as the flux increases. Contemporaneous multi-wavelength observations at lower energies (X-rays and gamma-rays above 300\approx 300~GeV) indicate smaller relative variability amplitudes than seen above 2~TeV during high flux state observed in April 2004.Comment: 5 pages, 4 figures, published in A&

    Very high energy gamma rays from the direction of Sagittarius A*.

    Get PDF
    We report the detection of a point-like source of very high energy (VHE) -rays coincident within 1' of Sgr A *, obtained with the HESS array of Cherenkov telescopes. The -rays exhibit a power-law energy spectrum with a spectral index of and a flux above the 165 GeV threshold of m -2 s -1. The measured flux and spectrum differ substantially from recent results reported in particular by the CANGAROO collaboration

    Discovery of the Binary Pulsar PSR B1259-63 in Very-High-Energy Gamma Rays around Periastron with H.E.S.S

    Get PDF
    We report the discovery of very-high-energy (VHE) gamma-ray emission of the binary system PSR B1259-63/SS 2883 of a radio pulsar orbiting a massive, luminous Be star in a highly eccentric orbit. The observations around the 2004 periastron passage of the pulsar were performed with the four 13 m Cherenkov telescopes of the H.E.S.S. experiment, recently installed in Namibia and in full operation since December 2003. Between February and June 2004, a gamma-ray signal from the binary system was detected with a total significance above 13 sigma. The flux was found to vary significantly on timescales of days which makes PSR B1259-63 the first variable galactic source of VHE gamma-rays observed so far. Strong emission signals were observed in pre- and post-periastron phases with a flux minimum around periastron, followed by a gradual flux decrease in the months after. The measured time-averaged energy spectrum above a mean threshold energy of 380 GeV can be fitted by a simple power law F_0(E/1 TeV)^-Gamma with a photon index Gamma = 2.7+-0.2_stat+-0.2_sys and flux normalisation F_0 = (1.3+-0.1_stat+-0.3_sys) 10^-12 TeV^-1 cm^-2 s^-1. This detection of VHE gamma-rays provides unambiguous evidence for particle acceleration to multi-TeV energies in the binary system. In combination with coeval observations of the X-ray synchrotron emission by the RXTE and INTEGRAL instruments, and assuming the VHE gamma-ray emission to be produced by the inverse Compton mechanism, the magnetic field strength can be directly estimated to be of the order of 1 G.Comment: 10 pages, 8 figures, accepted in Astronomy and Astrophysics on 2 June 2005, replace: document unchanged, replaced author field in astro-ph entry - authors are all members of the H.E.S.S. collaboration and three additional authors (99+3, see document

    First detection of a VHE gamma-ray spectral maximum from a Cosmic source: H.E.S.S. discovery of the Vela X nebula

    Get PDF
    The Vela supernova remnant (SNR) is a complex region containing a number of sources of non-thermal radiation. The inner section of this SNR, within 2 degrees of the pulsar PSR B0833-45, has been observed by the H.E.S.S. gamma-ray atmospheric Cherenkov detector in 2004 and 2005. A strong signal is seen from an extended region to the south of the pulsar, within an integration region of radius 0.8 deg. around the position (RA = 08h 35m 00s, dec = -45 deg. 36' J2000.0). The excess coincides with a region of hard X-ray emission seen by the ROSAT and ASCA satellites. The observed energy spectrum of the source between 550 GeV and 65 TeV is well fit by a power law function with photon index = 1.45 +/- 0.09(stat) +/- 0.2(sys) and an exponential cutoff at an energy of 13.8 +/- 2.3(stat) +/- 4.1(sys) TeV. The integral flux above 1 TeV is (1.28 +/- 0.17 (stat) +/- 0.38(sys)) x 10^{-11} cm^{-2} s^{-1}. This result is the first clear measurement of a peak in the spectral energy distribution from a VHE gamma-ray source, likely related to inverse Compton emission. A fit of an Inverse Compton model to the H.E.S.S. spectral energy distribution gives a total energy in non-thermal electrons of ~2 x 10^{45} erg between 5 TeV and 100 TeV, assuming a distance of 290 parsec to the pulsar. The best fit electron power law index is 2.0, with a spectral break at 67 TeV.Comment: 5 pages, 4 figures, accepted for publication in Astronomy and Astrophysics letter
    corecore