867 research outputs found
Economic method for measuring ultra-low flow rates of fluids
Capillary tube flowmeter measures ultra-low flows of very corrosive fluids /such as chlorine trifluoride and liquid fluorine/ and other liquids with reasonable accuracy. Flowmeter utilizes differential pressure transducer and operates on the principle that for laminar flow in the tube, pressure drop is proportional to flow rate
Simulations of MHD Instabilities in Intracluster Medium Including Anisotropic Thermal Conduction
We perform a suite of simulations of cooling cores in clusters of galaxies in
order to investigate the effect of the recently discovered heat flux buoyancy
instability (HBI) on the evolution of cores. Our models follow the
3-dimensional magnetohydrodynamics (MHD) of cooling cluster cores and capture
the effects of anisotropic heat conduction along the lines of magnetic field,
but do not account for the cosmological setting of clusters or the presence of
AGN. Our model clusters can be divided into three groups according to their
final thermodynamical state: catastrophically collapsing cores, isothermal
cores, and an intermediate group whose final state is determined by the initial
configuration of magnetic field. Modeled cores that are reminiscent of real
cluster cores show evolution towards thermal collapse on a time scale which is
prolonged by a factor of ~2-10 compared with the zero-conduction cases. The
principal effect of the HBI is to re-orient field lines to be perpendicular to
the temperature gradient. Once the field has been wrapped up onto spherical
surfaces surrounding the core, the core is insulated from further conductive
heating (with the effective thermal conduction suppressed to less than 1/100th
of the Spitzer value) and proceeds to collapse. We speculate that, in real
clusters, the central AGN and possibly mergers play the role of "stirrers,"
periodically disrupting the azimuthal field structure and allowing thermal
conduction to sporadically heat the core.Comment: 16 pages, 3 tables, 17 figures, accepted to ApJ with minor revisions,
to appear in Volume 704, Oct 20, 2009 issu
Electronic Structure of the Complex Hydride NaAlH4
Density functional calculations of the electronic structure of the complex
hydride NaAlH4 and the reference systems NaH and AlH3 are reported. We find a
substantially ionic electronic structure for NaAlH4, which emphasizes the
importance of solid state effects in this material. The relaxed hydrogen
positions in NaAlH4 are in good agreement with recent experiment. The
electronic structure of AlH3 is also ionic. Implications for the binding of
complex hydrides are discussed.Comment: 4 pages, 5 figure
Electronic structure and optical properties of lightweight metal hydrides
We study the electronic structures and dielectric functions of the simple
hydrides LiH, NaH, MgH2 and AlH3, and the complex hydrides Li3AlH6, Na3AlH6,
LiAlH4, NaAlH4 and Mg(AlH4)2, using first principles density functional theory
and GW calculations. All these compounds are large gap insulators with GW
single particle band gaps varying from 3.5 eV in AlH3 to 6.5 eV in the MAlH4
compounds. The valence bands are dominated by the hydrogen atoms, whereas the
conduction bands have mixed contributions from the hydrogens and the metal
cations. The electronic structure of the aluminium compounds is determined
mainly by aluminium hydride complexes and their mutual interactions. Despite
considerable differences between the band structures and the band gaps of the
various compounds, their optical responses are qualitatively similar. In most
of the spectra the optical absorption rises sharply above 6 eV and has a strong
peak around 8 eV. The quantitative differences in the optical spectra are
interpreted in terms of the structure and the electronic structure of the
compounds.Comment: 13 pages, 10 figure
Diagnostic accuracy and clinical applicability of the Swedish version of the 4AT assessment test for delirium detection, in a mixed patient population and setting
Background: Delirium is common in older hospitalized patients. It has serious consequences e.g., poor health outcomes, mortality and increased costs. Despite that, many cases are undetected. Early detection of delirium is important in improving outcomes and use of assessment tools improves detection rates. The 4AT is a brief screening tool for delirium detection, which has not previously been translated into Swedish. The study aim was to evaluate diagnostic accuracy and clinical applicability of a Swedish version of the screening tool 4AT for delirium detection.
Method: This diagnostic test accuracy study used a quantitative and a qualitative approach and evaluated the patients’ and the health care professionals’ experiences of the tool. Study included 200 patients ≥65 years from a university hospital and a county hospital in two Swedish regions. Medical specialties were geriatric stroke/neurology, geriatric multimorbidity, severe cognitive impairment, orthopaedic, and urology. The translated 4AT was tested against the reference standard DSM-IV-TR criteria, based on the Organic Brain Syndrome scale and patient records. The 4AT was assessed simultaneously and independently by two assessors. Additionally, data was collected through patient record reviews, and questions about applicability to the patients (n = 200) and the assessors (n = 37). Statistical analyses, and qualitative content analyses were conducted.
Results: By reference standard 18% had delirium, and by 4AT 19%. The overall percent agreement was 88%, AUROC 0.808, sensitivity 0.70 (95% CI 0.51–0.84) and specificity 0.92 (95% CI 0.87–0.96). In the ward for severe cognitive impairment (n = 63) the 4AT was less sensitive and less specific. In the other wards (n = 132) sensitivity was 0.77 (95% CI 0.50–0.93), specificity 0.93 (95% CI 0.87–0.97), and AUROC 0.848. Interrater reliability (Kappa) was 0.918, p = \u3c 0.001 (n = 144). The 4AT was well tolerated by patients, easy to use for health care professionals, and took a few minutes to conduct.
Conclusion: The Swedish version of 4AT is an accurate and applicable tool to use in clinical practice for detecting delirium in hospitalized patients across different medical specialities, and to use by different professionals and levels of seniority. To improve patient outcomes, we recommend the 4AT to be incorporated in clinical practice in health care settings in Sweden
Structure and Thermodynamics of the Mixed Alkali Alanates
The thermodynamics and structural properties of the hexahydride alanates
(M2M'AlH6) with the elpasolite structure have been investigated. A series of
mixed alkali alanates (Na2LiAlH6, K2LiAlH6 and K2NaAlH6) were synthesized and
found to reversibly absorb and desorb hydrogen without the need for a catalyst.
Pressure-composition isotherms were measured to investigate the thermodynamics
of the absorption and desorption reactions with hydrogen. Isotherms for
catalyzed (4 mol% TiCl3) and uncatalyzed Na2LiAlH6 exhibited an increase in
kinetics, but no change in the bulk thermodynamics with the addition of a
dopant. A structural analysis using synchrotron x-ray diffraction showed that
these compounds favor the Fm-3m space group with the smaller ion (M') occupying
an octahedral site. These results demonstrate that appropriate cation
substitutions can be used to stabilize or destabilize the material and may
provide an avenue to improving the unfavorable thermodynamics of a number of
materials with promising gravimetric hydrogen densities.Comment: 6 pages, 7 figures,3 tables, submitted to PR
Revisiting dual AGN candidates with spatially resolved LBT spectroscopy: The impact of spillover light contamination
Context. The merging of supermassive black holes (SMBHs) is a direct consequence of our hierarchical picture of galaxy evolution. It is difficult to track the merging process of SMBHs during mergers of galaxies as SMBHs are naturally difficult to observe. Aims. We want to characterise and confirm the presence of two independent active galactic nuclei (AGN) separated by a few kiloparsec in seven strongly interacting galaxies previously selected from the Sloan Digital Sky Survey (SDSS) as Seyfert-Seyfert pairs based on emission-line ratio diagnostics. Methods. Optical slit spectra taken with MODS at the Large Binocular Telescope are presented to infer the detailed spatial distribution of optical emission lines, and their line ratios and AGN signatures with respect to the host galaxies, thereby quantifying the impact of beam smearing and large fibre apertures on the spectra captured by the SDSS. Results. We find that at most two of the seven targets actually retain a Seyfert-Seyfert dual AGN, whereas the others may be more likely powered by post-AGB stars in retired galaxies or through shocks in the ISM based on spatially resolved optical line diagnostics. The major cause of this discrepancy is a bias caused by the spillover of flux from the primary source in the secondary SDSS fibre which can be more than an order of magnitude at < 3\u2033 separations. Previously reported extremely low X-ray-to-[O III] luminosity ratios may be explained by this misclassification, as can heavily obscured AGN for the primaries. We also find that the nuclei with younger stellar ages host the primary AGN. Conclusions. Studies of close dual AGN selected solely from fibre-based spectroscopy can create severe biases in the sample selection and interpretation of the results. Spatially resolved spectroscopy should ideally be used in the future to characterise such compact systems together with multi-wavelength follow-up observations
A block to pre-prepared movement in gait freezing, relieved by pedunculopontine nucleus stimulation
Gait freezing and postural instability are disabling features of Parkinsonian disorders, treatable with pedunculopontine nucleus stimulation. Both features are considered deficits of proximal and axial musculature, innervated predominantly by reticulospinal pathways and tend to manifest when gait and posture require adjustment. Adjustments to gait and posture are amenable to pre-preparation and rapid triggered release. Experimentally, such accelerated release can be elicited by loud auditory stimuli—a phenomenon known as ‘StartReact’. We observed StartReact in healthy and Parkinsonian controls. However, StartReact was absent in Parkinsonian patients with severe gait freezing and postural instability. Pedunculopontine nucleus stimulation restored StartReact proximally and proximal reaction times to loud stimuli correlated with gait and postural disturbance. These findings suggest a relative block to triggered, pre-prepared movement in gait freezing and postural instability, relieved by pedunculopontine nucleus stimulation
A quasar companion to the puzzling quasar SDSS J0927+2943
We report the discovery of a quasar close to SDSS J0927+2943 (z = 0.713),
which is a massive binary / recoiling black hole candidate. The companion
quasar is at a projected distance of 125 h_70^{-1} kpc and exhibits a radial
velocity difference of ~1400 km/s with respect to the known quasar. We discuss
the nature of this peculiar quasar pair and the properties of its environment.
We propose that the overall system is caught in the process of ongoing
structure formation.Comment: 4 pages, 3 figures. Accepted for publication in A&
- …