326 research outputs found

    Spatial heterogeneity and peptide availability determine CTL killing efficiency in vivo

    Get PDF
    The rate at which a cytotoxic T lymphocyte (CTL) can survey for infected cells is a key ingredient of models of vertebrate immune responses to intracellular pathogens. Estimates have been obtained using in vivo cytotoxicity assays in which peptide-pulsed splenocytes are killed by CTL in the spleens of immunised mice. However the spleen is a heterogeneous environment and splenocytes comprise multiple cell types. Are some cell types intrinsically more susceptible to lysis than others? Quantitatively, what impacts are made by the spatial distribution of targets and effectors, and the level of peptide-MHC on the target cell surface? To address these questions we revisited the splenocyte killing assay, using CTL specific for an epitope of influenza virus. We found that at the cell population level T cell targets were killed more rapidly than B cells. Using modeling, quantitative imaging and in vitro killing assays we conclude that this difference in vivo likely reflects different migratory patterns of targets within the spleen and a heterogeneous distribution of CTL, with no detectable difference in the intrinsic susceptibilities of the two populations to lysis. Modeling of the stages involved in the detection and killing of peptide-pulsed targets in vitro revealed that peptide dose influenced the ability of CTL to form conjugates with targets but had no detectable effect on the probability that conjugation resulted in lysis, and that T cell targets took longer to lyse than B cells. We also infer that incomplete killing in vivo of cells pulsed with low doses of peptide may be due to a combination of heterogeneity in peptide uptake and the dissociation, but not internalisation, of peptide-MHC complexes. Our analyses demonstrate how population-averaged parameters in models of immune responses can be dissected to account for both spatial and cellular heterogeneity

    Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Different radiation-techniques in treating local staged prostate cancer differ in their dose- distribution. Physical phantom measurements indicate that for 3D, less healthy tissue is exposed to a relatively higher dose compared to SSIMRT. The purpose is to substantiate a dose distribution in lymphocytes <it>in-vivo </it>and to discuss the possibility of comparing it to the physical model of total body dose distribution.</p> <p>Methods</p> <p>For each technique (3D and SSIMRT), blood was taken from 20 patients before and 10 min after their first fraction of radiotherapy. The isolated leukocytes were fixed 2 hours after radiation. DNA double-strand breaks (DSB) in lymphocytes' nuclei were stained immunocytochemically using the gamma-H2AX protein. Gamma-H2AX foci inside each nucleus were counted in 300 irradiated as well as 50 non-irradiated lymphocytes per patient. In addition, lymphocytes of 5 volunteer subjects were irradiated externally at different doses and processed under same conditions as the patients' lymphocytes in order to generate a calibration-line. This calibration-line assigns dose-value to mean number of gamma-H2AX foci/ nucleus. So the dose distributions in patients' lymphocytes were determined regarding to the gamma-H2AX foci distribution. With this information a cumulative dose-lymphocyte-histogram (DLH) was generated. Visualized distribution of gamma-H2AX foci, correspondingly dose per nucleus, was compared to the technical dose-volume-histogram (DVH), related to the whole body-volume.</p> <p>Results</p> <p>Measured <it>in-vivo </it>(DLH) and according to the physical treatment-planning (DVH), more lymphocytes resulted with low-dose exposure (< 20% of the applied dose) and significantly fewer lymphocytes with middle-dose exposure (30%-60%) during Step-and-Shoot-IMRT, compared to conventional 3D conformal radiotherapy. The high-dose exposure (> 80%) was equal in both radiation techniques. The mean number of gamma-H2AX foci per lymphocyte was 0.49 (3D) and 0.47 (SSIMRT) without significant difference.</p> <p>Conclusions</p> <p><it>In-vivo </it>measurement of the dose distribution within patients' lymphocytes can be performed by detecting gamma-H2AX foci. In case of 3D and SSIMRT, the results of this method correlate with the physical calculated total body dose-distribution, but cannot be interpreted unrestrictedly due to the blood circulation. One possible application of the present method could be in radiation-protection for <it>in-vivo </it>dose estimation after accidental exposure to radiation.</p

    Influence of oxygen tension on myocardial performance. Evaluation by tissue Doppler imaging

    Get PDF
    BACKGROUND: Low O(2 )tension dilates coronary arteries and high O(2 )tension is a coronary vasoconstrictor but reports on O(2)-dependent effects on ventricular performance diverge. Yet oxygen supplementation remains first line treatment in cardiovascular disease. We hypothesized that hypoxia improves and hyperoxia worsens myocardial performance. METHODS: Seven male volunteers (mean age 38 ± 3 years) were examined with echocardiography at respiratory equilibrium during: 1) normoxia (≈21% O(2), 79% N(2)), 2) while inhaling a hypoxic gas mixture (≈11% O(2), 89% N(2)), and 3) while inhaling 100% O(2). Tissue Doppler recordings were acquired in the apical 4-chamber, 2-chamber, and long-axis views. Strain rate and tissue tracking displacement analyses were carried out in each segment of the 16-segment left ventricular model and in the basal, middle and apical portions of the right ventricle. RESULTS: Heart rate increased with hypoxia (68 ± 4 bpm at normoxia vs. 79 ± 5 bpm, P < 0.001) and decreased with hyperoxia (59 ± 5 bpm, P < 0.001 vs. normoxia). Hypoxia increased strain rate in four left ventricular segments and global systolic contraction amplitude was increased (normoxia: 9.76 ± 0.41 vs hypoxia: 10.87 ± 0.42, P < 0.001). Tissue tracking displacement was reduced in the right ventricular segments and tricuspid regurgitation increased with hypoxia (7.5 ± 1.9 mmHg vs. 33.5 ± 1.8 mmHg, P < 0.001). The TEI index and E/E' did not change with hypoxia. Hyperoxia reduced strain rate in 10 left ventricular segments, global systolic contraction amplitude was decreased (8.83 ± 0.38, P < 0.001 vs. normoxia) while right ventricular function was unchanged. The spectral and tissue Doppler TEI indexes were significantly increased but E/E' did not change with hyperoxia. CONCLUSION: Hypoxia improves and hyperoxia worsens systolic myocardial performance in healthy male volunteers. Tissue Doppler measures of diastolic function are unaffected by hypoxia/hyperoxia which support that the changes in myocardial performance are secondary to changes in vascular tone. It remains to be settled whether oxygen therapy to patients with heart disease is a consistent rational treatment

    Perioperative and long-term operative outcomes after surgery for trigeminal neuralgia: microvascular decompression vs percutaneous balloon ablation

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>Numerous medical and surgical therapies have been utilized to treat the symptoms of trigeminal neuralgia (TN). This retrospective study compares patients undergoing either microvascular decompression or balloon ablation of the trigeminal ganglion and determines which produces the best long-term outcomes.</p> <p>Methods</p> <p>A 10-year retrospective chart review was performed on patients who underwent microvascular decompression (MVD) or percutaneous balloon ablation (BA) surgery for TN. Demographic data, intraoperative variables, length of hospitalization and symptom improvement were assessed along with complications and recurrences of symptoms after surgery. Appropriate statistical comparisons were utilized to assess differences between the two surgical techniques.</p> <p>Results</p> <p>MVD patients were younger but were otherwise similar to BA patients. Intraoperatively, twice as many BA patients developed bradycardia compared to MVD patients. 75% of BA patients with bradycardia had an improvement of symptoms. Hospital stay was shorter in BA patients but overall improvement of symptoms was better with MVD. Postoperative complication rates were similar (21% vs 26%) between the BA and MVD groups.</p> <p>Discussion</p> <p>MVD produced better overall outcomes compared to BA and may be the procedure of choice for surgery to treat TN.</p

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Detection of a Single Identical Cytomegalovirus (CMV) Strain in Recently Seroconverted Young Women

    Get PDF
    Infection with multiple CMV strains is common in immunocompromised hosts, but its occurrence in normal hosts has not been well-studied.We analyzed CMV strains longitudinally in women who acquired CMV while enrolled in a CMV glycoprotein B (gB) vaccine trial. Sequencing of four variable genes was performed in samples collected from seroconversion and up to 34 months thereafter.199 cultured isolates from 53 women and 65 original fluids from a subset of 19 women were sequenced. 51 women were infected with one strain each without evidence for genetic drift; only two women shed multiple strains. Genetic variability among strains increased with the number of sequenced genetic loci. Nevertheless, 13 of 53 women proved to be infected with an identical CMV strain based on sequencing at all four variable genes. CMV vaccine did not alter the degree of genetic diversity amongst strains.Primary CMV infection in healthy women nearly always involves shedding of one strain that remains stable over time. Immunization with CMVgB-1 vaccine strain is not selective against specific strains. Although 75% of women harbored their unique strain, or a strain shared with only one other woman, 25% shared a single common strain, suggesting that this predominant strain with a particular combination of genetic loci is advantageous in this large urban area
    • 

    corecore