51 research outputs found

    Effects of accelerated versus standard care surgery on the risk of acute kidney injury in patients with a hip fracture: a substudy protocol of the hip fracture accelerated surgical treatment and care track (HIP ATTACK) international randomised controlled trial

    Get PDF
    Accelerated surgery; Acute kidney injury; Hip fractureCirugía acelerada; Lesión renal aguda; Fractura de caderaCirurgia accelerada; Lesions renals agudes; Fractura de malucIntroduction: Inflammation, dehydration, hypotension and bleeding may all contribute to the development of acute kidney injury (AKI). Accelerated surgery after a hip fracture can decrease the exposure time to such contributors and may reduce the risk of AKI. Methods and analysis: Hip fracture Accelerated surgical TreaTment And Care tracK (HIP ATTACK) is a multicentre, international, parallel-group randomised controlled trial (RCT). Patients who suffer a hip fracture are randomly allocated to either accelerated medical assessment and surgical repair with a goal of surgery within 6 hours of diagnosis or standard care where a repair typically occurs 24 to 48 hours after diagnosis. The primary outcome of this substudy is the development of AKI within 7 days of randomisation. We anticipate at least 1998 patients will participate in this substudy. Ethics and dissemination: We obtained ethics approval for additional serum creatinine recordings in consecutive patients enrolled at 70 participating centres. All patients provide consent before randomisation. We anticipate reporting substudy results by 2021. Trial registration number: NCT02027896; Pre-results.This work was supported by the following grants: Canadian Institute of Health and Research (CIHR) Foundation Award, CIHR’s Strategy for Patient Oriented Research (SPOR), through the Ontario SPOR Support Unit, which is supported by the CIHR and the Province of Ontario, as well as the Ontario Ministry of Health and Long-Term Care, and a grant from Smith & Nephew to recruit 300 patients in Spain. Grants to support this substudy were provided by the Department of Medicine at Western University. Dr Devereaux was supported by a Tier 1 Canada Research Chair in Perioperative Medicine. Dr Amit Garg was supported by the Dr Adam Linton Chair in Kidney Health Analytics and a CIHR Clinician Investigator Award

    Tectonic and neotectonic implications of a new basement map of the Lower Tagus Valley, Portugal

    Get PDF
    In this paper we present a new basement (defined here as Paleozoic, Precambrian and Mesozoic igneous rocks) map of the Lower Tagus Valley area. This map is a contribution to the understanding of the structural evolution of the top of the basement in the Lower Tagus Valley area during the Mesozoic and Cenozoic Eras. The map was produced using aeromagnetic, well, seismic reflection and geological outcrop data. It shows unprecedented details of the geometry of the basement rock's surface with higher resolution and covers a larger area than the previous basement map of the study area. In spite of an estimated average error of 200 m in depth and an horizontal resolution of 4 km, our map not only reproduces with accuracy several well known basement structures but it also emphasizes previously unknown features. Major basement faults were inferred from large depth variations at the top of the basement, magnetic 2D Euler deconvolution and horizontal gradient analysis and are compatible with surface geological structures, well data and hydrogeological information. Implications to the geodynamic evolution of the SW European Variscides and consequences to Meso-Cenozoic tectonics are discussed. The correlation of the basement structures with instrumental seismicity is carried out and their neotectonic activity is discussed on the basis of existing geological outcrop data

    Compilation of parameterized seismogenic sources in Iberia for the SHARE European-scale seismic source model.

    Get PDF
    Abstract: SHARE (Seismic Hazard Harmonization in Europe) is an EC-funded project (FP7) that aims to evaluate European seismic hazards using an integrated, standardized approach. In the context of SHARE, we are compiling a fully-parameterized active fault database for Iberia and the nearby offshore region. The principal goal of this initiative is for fault sources in the Iberian region to be represented in SHARE and incorporated into the source model that will be used to produce seismic hazard maps at the European scale. The SHARE project relies heavily on input from many regional experts throughout the Euro-Mediterranean region. At the SHARE regional meeting for Iberia, the 2010 Working Group on Iberian Seismogenic Sources (WGISS) was established; these researchers are contributing to this large effort by providing their data to the Iberian regional integrators in a standardized format. The development of the SHARE Iberian active fault database is occurring in parallel with IBERFAULT, another ongoing effort to compile a database of active faults in the Iberian region. The SHARE Iberian active fault database synthesizes a wide range of geological and geophysical observations on active seismogenic sources, and incorporates existing compilations (e.g., Cabral, 1995; Silva et al., 2008), original data contributed directly from researchers, data compiled from the literature, parameters estimated using empirical and analytical relationships, and, where necessary, parameters derived using expert judgment. The Iberian seismogenic source model derived for SHARE will be the first regional-scale source model for Iberia that includes fault data and follows an internationally standardized approach (Basili et al., 2008; 2009). This model can be used in both seismic hazard and risk analyses and will be appropriate for use in Iberian- and European-scale assessments

    NEXT-100 Technical Design Report (TDR). Executive Summary

    Get PDF
    In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.Comment: 32 pages, 22 figures, 5 table

    Near-intrinsic energy resolution for 30-662 keV gamma rays in a high pressure xenon electroluminescent TPC

    Get PDF
    We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 136Xe neutrino-less double beta decay (0νββ) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of ∼1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and ∼5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2,459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7 to 20 better than that of the current leading 0νββ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT-DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 0νββ search

    Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

    Get PDF
    A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of similar to 35 cm drift x 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (similar to 23 l) so as to contain long (similar to 20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%) TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6% was obtained for similar to 29 keV gammas without resorting to any data post-processing

    Present Status and Future Perspectives of the NEXT Experiment

    Get PDF
    NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the 136Xe isotope. It is under construction in the Laboratorio Subterráneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolutionbetter than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1 ton-scale experiment

    Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment

    Get PDF
    NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterraneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the beta beta 0 nu events provides a powerful background rejection factor for the beta beta experiment. In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degrees C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/mu s, which enables recording most of the tracking signals
    corecore