391 research outputs found
Approximate conditional distributions of distances between nodes in a two-dimensional sensor network
When we represent a network of sensors in Euclidean space by a graph, there
are two distances between any two nodes that we may consider. One of them is
the Euclidean distance. The other is the distance between the two nodes in the
graph, defined to be the number of edges on a shortest path between them. In
this paper, we consider a network of sensors placed uniformly at random in a
two-dimensional region and study two conditional distributions related to these
distances. The first is the probability distribution of distances in the graph,
conditioned on Euclidean distances; the other is the probability density
function associated with Euclidean distances, conditioned on distances in the
graph. We study these distributions both analytically (when feasible) and by
means of simulations. To the best of our knowledge, our results constitute the
first of their kind and open up the possibility of discovering improved
solutions to certain sensor-network problems, as for example sensor
localization
Coherent matter wave inertial sensors for precision measurements in space
We analyze the advantages of using ultra-cold coherent sources of atoms for
matter-wave interferometry in space. We present a proof-of-principle experiment
that is based on an analysis of the results previously published in [Richard et
al., Phys. Rev. Lett., 91, 010405 (2003)] from which we extract the ratio h/m
for 87Rb. This measurement shows that a limitation in accuracy arises due to
atomic interactions within the Bose-Einstein condensate
Identification of risk factors for malaria control by focused interventions in Ranchi district, Jharkhand, India
Background & objectives: Ranchi, the capital of Jharkhand state is endemic for malaria, particularly the Bundu Primary Health Centre (PHC) is the worst affected. Therefore, a study was initiated during 2009 using remote sensing (RS) and geographical information system (GIS) to identify risk factors responsible for high endemicity in this PHC.
Methods: Bundu and Angara in Ranchi district were identified as high and low malaria endemic PHCs based on epidemiological data of three years (2007–09). The habitation, streams, other water body, landform, PHC and village boundary thematic maps were prepared using IRS-P6/LISS III-IV imageries and macro level breeding sites were identified. Digital elevation model (DEM) of the PHCs was generated using Cartosat Stereo Pair images and from DEM, slope map was derived to calculate flat area. From slope, aspect map was derived to indicate direction of water flow. Length of perennial streams, area under rocky terrain and buffer zones of 250, 500 and 750 m were constructed around streams. High resolution remote sensing imageries were used to identify
micro level breeding sites. Based on macro-micro breeding sites, six villages from each PHC were selected randomly having combination of different parameters representing all ecotypes. Entomological data were collected during 2010–11 in pre- and post-monsoon seasons following standard techniques and analyzed statistically.
Differential analysis was attempted to comprehend socioeconomic and other determinants associated with malaria
transmission.
Results: The study identified eight risk factors responsible for higher malaria endemicity in Bundu in comparison to Angara PHC based on ecological, entomological, socioeconomic and other local parameters.
Conclusion: Focused interventions in integrated vector management (IVM) mode are required to be carried out in
the district for better management and control of disease
Impact of an International Nosocomial Infection Control Consortium multidimensional approach on central line-associated bloodstream infection rates in adult intensive care units in eight cities in India
SummaryObjectiveTo evaluate the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional infection control approach on central line-associated bloodstream infection (CLABSI) rates in eight cities of India.MethodsThis was a prospective, before-and-after cohort study of 35650 patients hospitalized in 16 adult intensive care units of 11 hospitals. During the baseline period, outcome surveillance of CLABSI was performed, applying the definitions of the CDC/NHSN (US Centers for Disease Control and Prevention/National Healthcare Safety Network). During the intervention, the INICC approach was implemented, which included a bundle of interventions, education, outcome surveillance, process surveillance, feedback on CLABSI rates and consequences, and performance feedback. Random effects Poisson regression was used for clustering of CLABSI rates across time periods.ResultsDuring the baseline period, 9472 central line (CL)-days and 61 CLABSIs were recorded; during the intervention period, 80898 CL-days and 404 CLABSIs were recorded. The baseline rate was 6.4 CLABSIs per 1000 CL-days, which was reduced to 3.9 CLABSIs per 1000 CL-days in the second year and maintained for 36 months of follow-up, accounting for a 53% CLABSI rate reduction (incidence rate ratio 0.47, 95% confidence interval 0.31–0.70; p=0.0001).ConclusionsImplementing the six components of the INICC approach simultaneously was associated with a significant reduction in the CLABSI rate in India, which remained stable during 36 months of follow-up
Measurement of the Atmospheric Muon Spectrum from 20 to 3000 GeV
The absolute muon flux between 20 GeV and 3000 GeV is measured with the L3
magnetic muon spectrometer for zenith angles ranging from 0 degree to 58
degree. Due to the large exposure of about 150 m2 sr d, and the excellent
momentum resolution of the L3 muon chambers, a precision of 2.3 % at 150 GeV in
the vertical direction is achieved.
The ratio of positive to negative muons is studied between 20 GeV and 500
GeV, and the average vertical muon charge ratio is found to be 1.285 +- 0.003
(stat.) +- 0.019 (syst.).Comment: Total 32 pages, 9Figure
Measurement of W Polarisation at LEP
The three different helicity states of W bosons produced in the reaction e+
e- -> W+ W- -> l nu q q~ at LEP are studied using leptonic and hadronic W
decays. Data at centre-of-mass energies \sqrt s = 183-209 GeV are used to
measure the polarisation of W bosons, and its dependence on the W boson
production angle. The fraction of longitudinally polarised W bosons is measured
to be 0.218 \pm 0.027 \pm 0.016 where the first uncertainty is statistical and
the second systematic, in agreement with the Standard Model expectation
Search for Anomalous Couplings in the Higgs Sector at LEP
Anomalous couplings of the Higgs boson are searched for through the processes
e^+ e^- -> H gamma, e^+ e^- -> e^+ e^- H and e^+ e^- -> HZ. The mass range 70
GeV < m_H < 190 GeV is explored using 602 pb^-1 of integrated luminosity
collected with the L3 detector at LEP at centre-of-mass energies
sqrt(s)=189-209 GeV. The Higgs decay channels H -> ffbar, H -> gamma gamma, H
-> Z\gamma and H -> WW^(*) are considered and no evidence is found for
anomalous Higgs production or decay. Limits on the anomalous couplings d, db,
Delta(g1z), Delta(kappa_gamma) and xi^2 are derived as well as limits on the H
-> gamma gamma and H -> Z gamma decay rates
Measurement of W Polarisation at LEP
The three different helicity states of W bosons produced in the reaction e+
e- -> W+ W- -> l nu q q~ at LEP are studied using leptonic and hadronic W
decays. Data at centre-of-mass energies \sqrt s = 183-209 GeV are used to
measure the polarisation of W bosons, and its dependence on the W boson
production angle. The fraction of longitudinally polarised W bosons is measured
to be 0.218 \pm 0.027 \pm 0.016 where the first uncertainty is statistical and
the second systematic, in agreement with the Standard Model expectation
Bose-Einstein Correlations of Neutral and Charged Pions in Hadronic Z Decays
Bose-Einstein correlations of both neutral and like-sign charged pion pairs
are measured in a sample of 2 million hadronic Z decays collected with the L3
detector at LEP. The analysis is performed in the four-momentum difference
range 300 MeV < Q < 2 GeV. The radius of the neutral pion source is found to be
smaller than that of charged pions. This result is in qualitative agreement
with the string fragmentation model
- …