1,280 research outputs found

    Tissue holder for experimental and Demonstration Surgery

    Get PDF
    Development of device for holding anatomical tissues during operations is discussed. Device consists of plastic dish with hemispherical recess in center to hold excised eyes. Low vacuum applied to underside of recess insures holding of part

    The Making of a Self-Neglect Severity Scale

    Get PDF
    Research in elder self-neglect has lagged behind that of other forms of mistreatment, despite the fact that self-neglect is the most common allegation reported to Adult Protective Service agencies throughout the US. The lack of a gold-standard to measure self-neglect has hampered efforts to study this phenomenon. Researchers designed the Self-neglect Severity Scale (SSS) based on interviews with Adult Protective Service workers and a national expert panel. The SSS is based on observation and interview and is administered in the home to include an environmental assessment. It was piloted, extensively field tested and then revised. The CREST SSS was developed using survey data and consultation with experts in the field. This instrument utilizes observer ratings, interview responses, and assesses subjects physical and environmental domains. It also assesses functional status as it relates to health and safety issues. After field and pilot testing the SSS was finalized and is currently undergoing reliability and validity testing. The CREST SSS was developed as a state scale to provide a common language for describing cases of self-neglect. It is the first self-neglect severity scale available to researchers. If found to be both reliable and valid it can be used in future intervention studies

    Defining emergency department episodes by severity and intensity: A 15-year study of Medicare beneficiaries

    Get PDF
    Background. Episodes of Emergency Department (ED) service use among older adults previously have not been constructed, or evaluated as multi-dimensional phenomena. In this study, we constructed episodes of ED service use among a cohort of older adults over a 15-year observation period, measured the episodes by severity and intensity, and compared these measures in predicting subsequent hospitalization. Methods. We conducted a secondary analysis of the prospective cohort study entitled the Survey on Assets and Health Dynamics among the Oldest Old (AHEAD). Baseline (1993) data on 5,511 self-respondents 70 years old were linked to their Medicare claims for 1991-2005. Claims then were organized into episodes of ED care according to Medicare guidelines. The severity of ED episodes was measured with a modified-NYU algorithm using ICD9-CM diagnoses, and the intensity of the episodes was measured using CPT codes. Measures were evaluated against subsequent hospitalization to estimate comparative predictive validity. Results. Over 15 years, three-fourths (4,171) of the 5,511 AHEAD participants had at least 1 ED episode, with a mean of 4.5 episodes. Cross-classification indicated the modified-NYU severity measure and the CPT-based intensity measure captured different aspects of ED episodes (kappa = 0.18). While both measures were significant independent predictors of hospital admission from ED episodes, the CPT measure had substantially higher predictive validity than the modified-NYU measure (AORs 5.70 vs. 3.31; p < .001). Conclusions. We demonstrated an innovative approach for how claims data can be used to construct episodes of ED care among a sample of older adults. We also determined that the modified-NYU measure of severity and the CPT measure of intensity tap different aspects of ED episodes, and that both measures were predictive of subsequent hospitalization. © 2010 Kaskie et al; licensee BioMed Central Ltd

    Present Status and Future Programs of the n_TOF Experiment

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License 3.0, which permits unrestricted use, distribution, and reproduction in any noncommercial medium, provided the original work is properly citedThe neutron time-of-flight facility n_TOF at CERN, Switzerland, operational since 2001, delivers neutrons using the Proton Synchrotron (PS) 20 GeV/c proton beam impinging on a lead spallation target. The facility combines a very high instantaneous neutron flux, an excellent time of flight resolution due to the distance between the experimental area and the production target (185 meters), a low intrinsic background and a wide range of neutron energies, from thermal to GeV neutrons. These characteristics provide a unique possibility to perform neutron-induced capture and fission cross-section measurements for applications in nuclear astrophysics and in nuclear reactor technology.The most relevant measurements performed up to now and foreseen for the future will be presented in this contribution. The overall efficiency of the experimental program and the range of possible measurements achievable with the construction of a second experimental area (EAR-2), vertically located 20 m on top of the n_TOF spallation target, might offer a substantial improvement in measurement sensitivities. A feasibility study of the possible realisation of the installation extension will be also presented

    GUP1 and its close homologue GUP2, encoding multi-membrane-spanning proteins involved in active glycerol uptake in Saccharomyces cerevisiae

    Get PDF
    Many yeast species can utilise glycerol, both as sole carbon source and as an osmolyte. In Saccharomyces cerevisiae, physiological studies have previously shown the presence of an active uptake system driven by electrogenic proton symport. We have used transposon mutagenesis to isolate mutants affected in the transport of glycerol into the cell. Here we present the identification of YGL084c, encoding a multi-membrane-spanning protein, as being essential for proton symport of glycerol into Saccharomyces cerevisiae. The gene is named GUP1 (Glycerol UPtake) and is important for growth on glycerol as carbon and energy source, as well as for osmotic protection by added glycerol, of a strain deficient in glycerol production. Another ORF, YPL189w, presenting a high degree of homology to YGL084c, similarly appears to be involved in active glycerol uptake in salt-containing glucose-based media in strains deficient in glycerol production. Analogously, this gene is named GUP2. To our knowledge, this is the first report on a gene product involved in active transport of glycerol in yeasts. Mutations with the same phenotypes occurred in two other open reading frames of previously unknown function, YDL074c and YPL180w.Comunidade Europeia (CE) - contract BIO4-CT95-0161

    Measurements of high-energy neutron-induced fission of (nat)Pb and (209)Bi

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License 3.0, which permits unrestricted use, distribution, and reproduction in any noncommercial medium, provided the original work is properly citedThe CERN Neutron Time-Of-Flight (n_TOF) facility is well suited to measure low cross sections as those of neutron-induced fission in subactinides. The cross section ratios of (nat)Pb and (209)Bi relative to (235)U and (238)U were measured using PPAC detectors and a fragment coincidence method that allows us to identify the fission events. The present experiment provides first results for neutron-induced fission up to 1 GeV. Good agreement is found with previous experimental data below 200 MeV. The comparison with proton-induced fission indicates that the limiting regime where neutron-induced and proton-induced fission reach equal cross sections is close to 1 GeV

    The (234)U neutron capture cross section measurement at the n_TOF facility

    Get PDF
    The neutron capture cross-section of (234)U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n_TOF, based on a spallation source located at CERN. A 4 pi BaF(2) array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt gamma-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of ENDF in the relevant energy region, indicating the good performance of the n_TOF facility and the TAC

    Measurement of the (90,91,92,93,94,96)Zr(n,gamma) and (139)La(n,gamma) cross sections at n_TOF

    Get PDF
    Open AccessNeutron capture cross sections of Zr and La isotopes have important implications in the field of nuclear astrophysics as well as in the nuclear technology. In particular the Zr isotopes play a key role for the determination of the neutron density in the He burning zone of the Red Giant star, while the (139)La is important to monitor the s-process abundances from Ba up to Ph. Zr is also largely used as structural materials of traditional and advanced nuclear reactors. The nuclear resonance parameters and the cross section of (90,91,92,93,94,96)Zr and (139)La have been measured at the n_TOF facility at CERN. Based on these data the capture resonance strength and the Maxwellian-averaged cross section were calculated

    Characterization of the n-TOF EAR-2 neutron beam

    Get PDF
    The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n-TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam prole and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash
    corecore