37 research outputs found

    The Influence of Spatial Registration on Detection of Cerebral Asymmetries Using Voxel-Based Statistics of Fractional Anisotropy Images and TBSS

    Get PDF
    The sensitivity of diffusion tensor imaging (DTI) for detecting microstructural white matter alterations has motivated the application of voxel-based statistics (VBS) to fractional anisotropy (FA) images (FA-VBS). However, detected group differences may depend on the spatial registration method used. The objective of this study was to investigate the influence of spatial registration on detecting cerebral asymmetries in FA-VBS analyses with reference to data obtained using Tract-Based Spatial Statistics (TBSS). In the first part of this study we performed FA-VBS analyses using three single-contrast and one multi-contrast registration: (i) whole-brain registration based on T2 contrast, (ii) whole-brain registration based on FA contrast, (iii) individual-hemisphere registration based on FA contrast, and (iv) a combination of (i) and (iii). We then compared the FA-VBS results with those obtained from TBSS. We found that the FA-VBS results depended strongly on the employed registration approach, with the best correspondence between FA-VBS and TBSS results when approach (iv), the “multi-contrast individual-hemisphere” method was employed. In the second part of the study, we investigated the spatial distribution of residual misregistration for each registration approach and the effect on FA-VBS results. For the FA-VBS analyses using the three single-contrast registration methods, we identified FA asymmetries that were (a) located in regions prone to misregistrations, (b) not detected by TBSS, and (c) specific to the applied registration approach. These asymmetries were considered candidates for apparent FA asymmetries due to systematic misregistrations associated with the FA-VBS approach. Finally, we demonstrated that the “multi-contrast individual-hemisphere” approach showed the least residual spatial misregistrations and thus might be most appropriate for cerebral FA-VBS analyses

    Bright light therapy versus physical exercise to prevent co-morbid depression and obesity in adolescents and young adults with attention-deficit/hyperactivity disorder: study protocol for a randomized controlled trial

    Get PDF
    Background: The risk for major depression and obesity is increased in adolescents and adults with attention-deficit / hyperactivity disorder (ADHD) and adolescent ADHD predicts adult depression and obesity. Non-pharmacological interventions to treat and prevent these co-morbidities are urgently needed. Bright light therapy (BLT) improves day– night rhythm and is an emerging therapy for major depression. Exercise intervention (EI) reduces obesity and improves depressive symptoms. To date, no randomized controlled trial (RCT) has been performed to establish feasibility and efficacy of these interventions targeting the prevention of co-morbid depression and obesity in ADHD. We hypothesize that the two manualized interventions in combination with mobile health-based monitoring and reinforcement will result in less depressive symptoms and obesity compared to treatment as usual in adolescents and young adults with ADHD. Methods: This trial is a prospective, pilot phase-IIa, parallel-group RCT with three arms (two add-on treatment groups [BLT, EI] and one treatment as usual [TAU] control group). The primary outcome variable is change in the Inventory of Depressive Symptomatology total score (observer-blinded assessment) between baseline and ten weeks of intervention. This variable is analyzed with a mixed model for repeated measures approach investigating the treatment effect with respect to all three groups. A total of 330 participants with ADHD, aged 14 – < 30 years, will be screened at the four study centers. To establish effect sizes, the sample size was planned at the liberal significance level of α = 0.10 (two-sided) and the power of 1-β = 80% in order to find medium effects. Secondary outcomes measures including change in obesity, ADHD symptoms, general psychopathology, health-related quality of life, neurocognitive function, chronotype, and physical fitness are explored after the end of the intervention and at the 12-week follow-up. This is the first pilot RCT on the use of BLT and EI in combination with mobile health-based monitoring and reinforcement targeting the prevention of co-morbid depression and obesity in adolescents and young adults with ADHD. If at least medium effects can be established with regard to the prevention of depressive symptoms and obesity, a larger scale confirmatory phase-III trial may be warranted.The trial is funded by the EU Framework Programme for Research and Innovation, Horizon 2020 (Project no. 667302). Funding period: January 2016–December 2020. This funding source had no role in the design of this study and will not have any role during its execution, analyses, interpretation of the data, or decision to submit results. Some local funds additionally contributed to carry out this study, especially for the preparation of the interventions: FBO research activity is by the Spanish Ministry of Economy and Competitiveness – MINECO (RYC-2011-09011) and by the University of Granada, Plan Propio de Investigación 2016, Excellence actions: Unit of Excellence on Exercise and Health (UCEES)

    The handbook for standardized field and laboratory measurements in terrestrial climate change experiments and observational studies (ClimEx)

    Get PDF
    1. Climate change is a world‐wide threat to biodiversity and ecosystem structure, functioning and services. To understand the underlying drivers and mechanisms, and to predict the consequences for nature and people, we urgently need better understanding of the direction and magnitude of climate change impacts across the soil–plant–atmosphere continuum. An increasing number of climate change studies are creating new opportunities for meaningful and high‐quality generalizations and improved process understanding. However, significant challenges exist related to data availability and/or compatibility across studies, compromising opportunities for data re‐use, synthesis and upscaling. Many of these challenges relate to a lack of an established ‘best practice’ for measuring key impacts and responses. This restrains our current understanding of complex processes and mechanisms in terrestrial ecosystems related to climate change. 2. To overcome these challenges, we collected best‐practice methods emerging from major ecological research networks and experiments, as synthesized by 115 experts from across a wide range of scientific disciplines. Our handbook contains guidance on the selection of response variables for different purposes, protocols for standardized measurements of 66 such response variables and advice on data management. Specifically, we recommend a minimum subset of variables that should be collected in all climate change studies to allow data re‐use and synthesis, and give guidance on additional variables critical for different types of synthesis and upscaling. The goal of this community effort is to facilitate awareness of the importance and broader application of standardized methods to promote data re‐use, availability, compatibility and transparency. We envision improved research practices that will increase returns on investments in individual research projects, facilitate second‐order research outputs and create opportunities for collaboration across scientific communities. Ultimately, this should significantly improve the quality and impact of the science, which is required to fulfil society's needs in a changing world

    Fetal Surgery for Gastroschisis&mdash;A Review with Emphasis on Minimally Invasive Procedures

    No full text
    (1) Background: The morbidity of gastroschisis is defined by exposure of unprotected intestines to the amniotic fluid leading to inflammatory damage and consecutive intestinal dysmotility, the viscero-abdominal disproportion which results in an abdomen too small to incorporate the herniated and often swollen intestine, and by associated pathologies, such as in complex gastroschisis. To prevent intestinal damage and to provide for growth of the abdominal cavity, fetal interventions such as amnio exchange, gastroschisis repair or covering have been evaluated in several animal models and human trials. This review aims to evaluate the reported techniques for the fetal treatment of gastroschisis by focusing on minimally invasive procedures. (2) Methods: We conducted a systematic database search, quality assessment and analyzed relevant articles which evaluate or describe surgical techniques for the prenatal surgical management of gastroschisis in animal models or human application. (3) Results: Of 96 identified reports, 42 eligible studies were included. Fetal interventions for gastroschisis in humans are only reported for EXIT procedures and amnio exchange. In animal models, particularly in the fetal sheep model, several techniques of open or minimally invasive repair of gastroschisis or covering the intestine have been described, with fetoscopic covering being the most encouraging. (4) Discussion: Although some promising minimally invasive techniques have been demonstrated in human application and animal models, most of them are still associated with relevant fetal morbidity and mortality and barely appear to be currently applicable in humans. Further research on specific procedures, instruments and materials is needed before any human application

    Advances and Trends in Pediatric Minimally Invasive Surgery

    No full text
    As many meta-analyses comparing pediatric minimally invasive to open surgery can be found in the literature, the aim of this review is to summarize the current state of minimally invasive pediatric surgery and specifically focus on the trends and developments which we expect in the upcoming years. Print and electronic databases were systematically searched for specific keywords, and cross-link searches with references found in the literature were added. Full-text articles were obtained, and eligibility criteria were applied independently. Pediatric minimally invasive surgery is a wide field, ranging from minimally invasive fetal surgery over microlaparoscopy in newborns to robotic surgery in adolescents. New techniques and devices, like natural orifice transluminal endoscopic surgery (NOTES), single-incision and endoscopic surgery, as well as the artificial uterus as a backup for surgery in preterm fetuses, all contribute to the development of less invasive procedures for children. In spite of all promising technical developments which will definitely change the way pediatric surgeons will perform minimally invasive procedures in the upcoming years, one must bear in mind that only hard data of prospective randomized controlled and double-blind trials can validate whether these techniques and devices really improve the surgical outcome of our patients

    Minimally Invasive Bimanual Fetal Surgery&mdash;A Review

    No full text
    Background: The aim of this review is to discuss experimental and clinical techniques and interventions of fetal surgery which have been performed minimally invasively by the means of a three-port approach for the fetoscope and instruments for the left and right hand of the surgeon (bimanual minimally invasive fetal surgery). Methods: a print and electronic literature search was performed; the titles and abstracts were screened and included reports were reviewed in a two-step approach. First, reports other than minimally invasive fetal surgery were excluded, then a full text review and analysis of the reported data was performed. Results: 17 reports were included. The heterogeneity of the included reports was high. Although reports on human fetoscopic surgical procedures can be found, most of them do not pick out bimanual fetal surgery as a central theme but rather address interventions applying a fetoscope with a working channel for a laser fiber, needle or flexible instrument. Most reports were on experimentation in animal models, the human application of minimally invasive fetoscopic bimanual surgery is rare and has at best been explored for the prenatal treatment of spina bifida. Some reported bimanual fetoscopic procedures were performed on the exteriorized uterus via a maternal laparotomy and can therefore not be classified as being truly minimally invasive. Discussion: our results demonstrate that minimally invasive fetoscopic bimanual surgery is rare, even in animal models, excluding many other techniques and procedures that are loosely termed &lsquo;minimally invasive fetal surgery&rsquo; which we suggest to better label as &lsquo;interventions&rsquo;. Thus, more research on percutaneous minimally invasive bimanual fetoscopic surgery is warranted, with the aim to reduce the maternal, uterine and fetal trauma for correction of congenital malformations

    Evaluation of the Versius Robotic Surgical System for Procedures in Small Cavities

    No full text
    Background: The Versius® is a recently approved robotic surgical system for general surgery procedures in adults. Before any application in children, data of its feasibility and safety in small cavities has to be compiled, beginning with inanimate models. Therefore, the aim of this preclinical study was to assess the Versius® system for its performance in small boxes simulating small body cavities. Methods: In total, 8 cardboard boxes of decreasing volumes (15.75 L to 106 mL) were used. The procedures, two single stitches with two square knots each, were performed in every box, starting in the largest and consecutively exchanging the box to the next smaller one. The evaluation included procedure time, port placement and pivot point setup, arrangement of the robotic arms and instrumentation, amount of internal and external instrument–instrument collisions and instrument–box collisions. Results: All procedures could be successfully performed in all boxes. The procedure time decreased due to the learning curve in the first four boxes (15.75 to 1.87 L) and consecutively increased from boxes of 1.22 L up to the smallest box with the dimensions of 4.4 × 4.9 × 4.9 cm3. This may be based on the progress of complexity of the procedures in small cavities, which is also depicted by the synchronous increase of the internal instrument–instrument and instrument–box collisions. Conclusion: With the use of the Versius® robotic surgical system, we were able to perform robotic reconstructive procedures, such as intracorporal suturing and knot tying, in cavities as small as 106 mL. Whether this system is comparable or even superior to conventional laparoscopic surgery in small cavities, such as in children, has to be evaluated. Furthermore, before any application in newborns or infants, ongoing evaluation of this system should be performed in a live animal model
    corecore