89 research outputs found

    Comparison of UV-B measurements performed with a Brewer spectrophotometer and a new UVB-1 broad band detector

    Get PDF
    Measurements of the UV-B erythemal dose, based on solar spectra acquired with a Brewer spectrophotometer at Thessaloniki, Greece, are compared to measurements performed with the recently introduced, by the Yankee Environmental Systems, (Robertson type) broad band solar UV-B detector. The spectral response function of this detector, when applied to the Brewer spectral UV-B measurements, results in remarkably comparable estimates of the erythemal UV-B dose. The two instruments provide similar information on the UV-B dose when they are cross-examined under a variety of meteorological and atmospheric conditions and over the a large range of solar zenith angles and total ozone

    The European COST Action EUBrewNet: towards consistency in quality control, quality assurance and coordinated operations of the Brewer Instrument

    Get PDF
    Presentación realizada en: 10th meeting of the Ozone Research Managers (ORM) como parte de "Vienna Convention for the Protection of the Ozone Layer", celebrado en Ginebra (Suiza) del 28 al 30 de marzo de 2017

    Dead time effect on the Brewer measurements: correction and estimated uncertainties

    Get PDF
    Brewer spectrophotometers are widely used instruments which perform spectral measurements of the direct, the scattered and the global solar UV irradiance. By processing these measurements a variety of secondary products can be derived such as the total columns of ozone (TOC), sulfur dioxide and nitrogen dioxide and aerosol optical properties. Estimating and limiting the uncertainties of the final products is of critical importance. High-quality data have a lot of applications and can provide accurate estimations of trends

    Ozone–climate interactions and effects on solar ultraviolet radiation

    Get PDF
    This report assesses the effects of stratospheric ozone depletion and anticipated ozone recovery on the intensity of ultraviolet (UV) radiation at the Earth's surface. Interactions between changes in ozone and changes in climate, as well as their effects on UV radiation, are also considered. These evaluations focus mainly on new knowledge gained from research conducted during the last four years. Furthermore, drivers of changes in UV radiation other than ozone are discussed and their relative importance is assessed. The most important of these factors, namely clouds, aerosols and surface reflectivity, are related to changes in climate, and some of their effects on short- and long-term variations of UV radiation have already been identified from measurements. Finally, projected future developments in stratospheric ozone, climate, and other factors affecting UV radiation have been used to estimate changes in solar UV radiation from the present to the end of the 21st century. New instruments and methods have been assessed with respect to their ability to provide useful and accurate information for monitoring solar UV radiation at the Earth's surface and for determining relevant exposures of humans. Evidence since the last assessment reconfirms that systematic and accurate long-term measurements of UV radiation and stratospheric ozone are essential for assessing the effectiveness of the Montreal Protocol and its Amendments and adjustments. Finally, we have assessed aspects of UV radiation related to biological effects and human health, as well as implications for UV radiation from possible solar radiation management (geoengineering) methods to mitigate climate change

    Investigating the role of functional polymorphism of maternal and neonatal vitamin D binding protein in the context of 25‐hydroxyvitamin D cutoffs as determinants of maternal‐neonatal vitamin D status profiles in a sunny mediterranean region

    Get PDF
    Recent results indicate that dysregulation of vitamin D‐binding protein (VDBP) could be involved in the development of hypovitaminosis D, and it comprises a risk factor for adverse fetal, maternal and neonatal outcomes. Until recently, there was a paucity of results regarding the effect of maternal and neonatal VDBP polymorphisms on vitamin D status during pregnancy in the Mediterranean region, with a high prevalence of hypovitaminosis D. We aimed to evaluate the combined effect of maternal and neonatal VDBP polymorphisms and different maternal and neonatal 25‐hy-droxyvitamin D (25(OH)D) cut‐offs on maternal and neonatal vitamin D profile. Blood samples were obtained from a cohort of 66 mother–child pairs at birth. Our results revealed that: (i) Maternal VDBP polymorphisms do not affect neonatal vitamin D status at birth, in any given internationally adopted maternal or neonatal cut‐off for 25(OH)D concentrations; (ii) neonatal VDBP polymor-phisms are not implicated in the regulation of neonatal vitamin D status at birth; (iii) comparing the distributions of maternal VDBP polymorphisms and maternal 25(OH)D concentrations, with cutoffs at birth, revealed that mothers with a CC genotype for rs2298850 and a CC genotype for rs4588 tended to demonstrate higher 25(OH)D (≥75 nmol/L) during delivery (p = 0.05 and p = 0.04, respec-tively), after adjustments for biofactors that affect vitamin D equilibrium, including UVB, BMI and weeks of gestation. In conclusion, this study from Southern Europe indicates that maternal and neonatal VDBP polymorphisms do not affect neonatal vitamin D status at birth, whereas mothers with CC genotype for rs2298850 and CC genotype for rs4588 demonstrate higher 25(OH)D concen-trations. Future larger studies are required to establish a causative effect of these specific polymor-phisms in the attainment of an adequate (≥75 nmol/L) maternal vitamin D status during pregnancy

    Second solar ultraviolet radiometer comparison campaign UVC-II

    Get PDF
    In 2017, PMOD/WRC organised the solar ultraviolet broadband radiometer comparison campaign UVC-II. All 75 participating instruments from all over the world were characterised in the laboratory of the World Calibration Center for UV (WCCUV) and calibrated outdoors relative to the Qasume reference spectroradiometer. After a three month calibration period, all devices were returned to their owners, accompanied by a certificate demonstrating traceability to the international system of units. The calibration uncertainty stated in these certificates was less than 6% for the majority of the radiometers. The deviation to the original calibration factors was analysed. From this data we determined three components affecting the overall measurement uncertainty of solar UV measurements using broadband radiometers on different time scales: Usage of additional correction factors to the absolute calibration factor, control of the humidity inside the device and recalibration frequency. A subset of radiometers participating in the campaign were calibrated and characterised at their home laboratories. A comparison of the calibration factors shows that the USER- and the WCCUV-calibrations agree within the uncertainties for 9 out of 11 calibrations

    The evolution of synoptic ozone anomalies during the European Arctic Stratospheric Ozone Experiment in winter 1991/1992

    Get PDF
    The evolution of ozone anomalies over the middle and high latitudes of the Northern Hemisphere during the winter 1991-1992 is studied in this work. The largest monthly mean negative deviations in the middle latitudes of the Northern Hemisphere were about 10 percent in November and December, and up to 20 percent in January, February, and March over Eurasian territories, and much smaller over the Canadian sector. At the end of January, on individual days, total ozone values of 190-210 D.U. were observed over Eastern Europe and European part of Russia, that is 40-45 percent below normal. On the whole, the 1991-1992 winter was one of the most anomalous over all the period of ozone observations. Finally, an attempt is made to quantify the contribution of transport in the ozone layer changes over Europe during this period

    Quality Assurance of Spectral Ultraviolet Measurements in Europe Through the Development of a Transportable Unit (QASUME)

    Get PDF
    QASUME is a European Commission funded project that aims to develop and test a transportable unit for providing quality assurance to UV spectroradiometric measurements conducted in Europe. The comparisons will be performed at the home sites of the instruments, thus avoiding the risk of transporting instruments to participate in intercomparison campaigns. Spectral measurements obtained at each of the stations will be compared, following detailed and objective comparison protocols, against collocated measurements performed by a thoroughly tested and validated travelling unit. The transportable unit comprises a spectroradiometer, its calibrator with a set of calibration lamps traceable to the sources of different Standards Laboratories, and devices for determining the slit function and the angular response of the local spectroradiometers. The unit will be transported by road to about 25 UV stations over a period of about two years. The spectroradiometer of the transportable unit is compared in an intercomparison campaign with six instruments to establish a relation, which would then be used as a reference for its calibration over the period of its regular operation at the European stations. Different weather patterns (from clear skies to heavy rain) were present during the campaign, allowing the performance of the spectroradiometers to be evaluated under unfavourable conditions (as may be experienced at home sites) as well as the more desirable dry conditions. Measurements in the laboratory revealed that the calibration standards of the spectroradiometers differ by up to 10%. The evaluation is completed through comparisons with the same six instruments at their homes sites
    corecore