43 research outputs found

    Glazing. Energy Efficiency in Office Buildings Retrofitting in the Mediterranean Peninsula Climate (1971-1980)

    Get PDF
    La apuesta 20 20 20 establece tres claros objetivos con el fin de reducir las emisiones de dióxido de carbono. La rehabilitación energética de edificios puede contribuir a ello en cualquiera de sus ámbitos constructivos y/o sistemas. En particular, el hueco es considerado la parte más influyente en el comportamiento energético lo que lo hace ser el primer elemento de la envolvente a ser valorado técnica y económicamente. La medida de eficiencia energética general que se realiza consiste en sustituir las ventanas por otras de mejores prestaciones de idénticas características aislantes y energéticas en todas las orientaciones. El acristalamiento bajo emisivo es el elegido por excelencia por su bajo valor de transmitancia térmica. Esto ha llevado a plantear poder conseguir un mayor incremento de eficiencia energética colocando, respecto a la superficie acristalada, aquel que mejor se adapte a cada orientación. Para ello, se ha realizado un profundo análisis del comportamiento teórico de los tres parámetros característicos que la definen (transmitancia térmica, factor solar y transmisión luminosa) que permita sentar las bases de una metodología en la sustitución del acristalamiento. Los edificios de oficinas son los más interesantes a estudiar por la sucesión de circunstancias, tales como, su elevada superficie vidriada, consumo energético y potencial aprovechamiento de la luz natural. Para ello, ha sido necesario diseñar un modelo basado en un conjunto de edificios representativos. Se ha englobado dentro de un periodo constructivo de mayor construcción y uso generalizado del vidrio monolítico sencillo (1971-1980), en tres entornos climáticos con severidad de invierno y verano completamente diferente (Barcelona «C2», Sevilla «B4» y Málaga «A3» en clima mediterráneo peninsular. Tres procedimientos de selección han sido analizados basados en la eliminación de los acristalamientos que no se ajusten a la secuencia establecida para cada parámetro característico. Secuencia, compuesta por la dirección, ascendente o descendente, y orden de influencia, elección del primer parámetro y sucesivamente. Con el orden binomio (transmitancia térmica y factor solar) y transmisión luminosa es con el que se consigue una reducción de emisiones en mayor número de orientaciones. Procedimiento utilizado en la propuesta de la metodología de sustitución del acristalamiento. Metodología que descarta las limitaciones producidas por cumplimiento de normativa o de diseño, al condicionar en parte éstas el grado de eficiencia energética a conseguir. Como conclusión, tanto la dirección como el orden de influencia de los parámetros son muy significativos si se quiere conseguir un menor consumo y emisiones de dióxido de carbono. La calefacción se identifica con transmitancia térmica baja, factor solar alto y transmisión luminosa baja. La refrigeración, con transmitancia térmica alta, factor solar bajo y transmisión luminosa alta. En el periodo anual, cuatro posibles combinaciones se pueden dar de transmitancia y factor solar, siendo ambas bajas la más repetitiva en las orientaciones de los espacios.The 20-20-20 strategy establishes three clear goals in order to reduce carbon dioxide emissions. Building energy retrofitting can contribute in any of the construction and/or systems areas. Opening is considered the most influential part in energy behavior becoming the first envelope design element to be assessed, technically and economically. The standard energy efficiency measure consists of replacing windows by others of better performance, placed equally in all façade orientations. Low-emissivity glazing is the choice for excellence U-value. This has brought the possibility of achieving greater energy efficiency by placing, regarding the glazed surface, the one that best suits each orientation. A thorough theoretical behavior analysis based on three parameters (thermal transmittance, solar heat gain coefficient and light transmittance) has been carried out, in order to lay the foundations of a selection criteria methodology. Office buildings are the most interesting due to their high glazed surface, energy consumption and potential use of natural light. A model has been designed based on a set of buildings with more geometric and construction similarities. The period studied has been of greater construction along with use of single monolithic glazing (1971-1980), located in the Mediterranean Peninsula Climate. Three climate zones of different winter and summer severity (Barcelona «C2», Seville «B4» and Malaga «A3») have been considered. Three glazing selection procedures have been analyzed, based on the elimination of those that do not follow each parameter sequence. A sequence based on: the up-and-down direction, and the order of influence, the selection of the first and last parameter. The thermal transmittance/solar heat gain coefficient and afterwards visible transmittance parameter combination, greater number of orientations a reduction of CO2 emissions has been achieved. Compliance with regulations or design limitations, determine in part, the degree of energy efficiency. In conclusion, the parameters’ direction and order of influence are very significant if lower consumption and carbon dioxide emissions want to be achieved. Heating identifies with low thermal transmittance, high SHGC and low visible transmittance. Cooling identifies with high thermal transmittance, low SHGC and high visible transmittance. In the annual period, four possible thermal transmittance and SHGC combinations can occur. In the north-south and eastwest building spaces orientations, both low combinations is the most repetitive one

    The influence of glazing over the parameters and energy rating according to the building orientation and the façade openings percentages

    Get PDF
    Es bien conocida la importancia de los cristales en la demanda de energía del edificio, ya que la envolvente térmica es lo más importante. En este trabajo se ha realizado un estudio de la influencia de la transmitancia térmica (factor U) y el factor solar (valor g) de tres tipos diferentes de acristalamiento en la calificación energética. Se ha realizado el análisis en una vivienda unifamiliar situada en la ciudad de Sevilla, España, con diferentes hipótesis, en concreto seis porcentajes de apertura que van desde 10 a 60% considerado por el Código Técnico de la Edificación español, y cuatro orientaciones según las direcciones cardinales. Para los tipos de zona climático y acristalamiento considerados, el valor del parámetro g tiene mayor incidencia en el rendimiento energético que la transmitancia térmica. Se ha establecido qué orientación proporciona mayor ahorro de energía, independientemente de la demanda de calefacción y enfriamiento y de la calificación energética. Además, hay que considerar los valores ideales de ambos parámetros para cada orientación con el fin de mejorar la calificación energética. Por lo tanto, al seleccionar un tipo de acristalamiento, sería importante tener en cuenta los mejores valores de los parámetros "T" y "g" para cada orientación con el fin de obtener menor gasto de energía.It is well known the significant impact of glazing over the building energy demand making it the thermal envelope’s most important part. A study of the influence of thermal transmittance (U-factor) and solar factor (g-value) of three different glazing types over the parameters and energy rating are shown in this paper. A single-family dwelling located in Seville city, Spain, has been analyzed to which a set of hypotheses, six opening percentages ranging from 10 to 60% considered by the Spanish Building Code on its simplified option, and different combinations, four orientations matching the cardinal directions, has been applied. For the climate zone and glazing types considered, the g-value parameter has a higher incidence on the global demand and energy rating than thermal transmittance. It is established which orientation greater energy savings can be achieved independently for heating, cooling demand and energy rating. Also the ideal values for both parameters that should be considered in each orientation in order to improve the energy rating. Therefore, when selecting a type of glazing it would be important to consider the best “U” and “g” parameter values together for each orientation in order to get the lowest energy demand possible

    Bases conceptuales para determinar los hábitos de consumo del segmento LGBT en la ciudad de Bogotá D.C.

    Get PDF
    Administrador (a) de EmpresasPregrad

    The influence of glazing on heating, cooling and lighting use in office building retrofitting in a peninsular Mediterranean climate (1971-1980)

    Get PDF
    Los edificios de oficinas existentes en España representan el 33% del consumo total del parque construido. Estos son mayoritariamente edificios previos a la entrada en vigor de Código Técnico de Edificación, por lo que son poco eficientes energéticamente y poseen una elevada superficie vidriada. Las puertas y ventanas suelen ser los primeros elementos a sustituir en las renovaciones de edificios y presentan una oportunidad de mejora. Para ello, el vidrio puede ser analizado según su configuración, unido a la inclusión de tratamiento de capa en algunas de las caras (bajo emisivo), y mediante los parámetros característicos: transmitancia térmica, coeficiente de ganancia térmica solar y transmisión luminosa. En este artículo, se analiza la sustitución de vidrios monolíticos sencillos, por vidrios de doble vidrio sin tratamiento de capa o bajo emisivo, analizados por orientaciones. Se estudian tres climas mediterráneos con diferentes severidades de invierno y verano en España (Barcelona, Sevilla y Málaga). En cuanto a la configuración y tratamiento de capa del vidrio, en calefacción, se obtiene un menor consumo energético con el vidrio sin tratamiento de capa con mayor transmitancia térmica, y en refrigeración, con el bajo emisivo. Por otro lado, si se analizan los parámetros característicos, un menor consumo de calefacción se consigue con una transmitancia térmica baja, factor solar alto y transmisión luminosa baja, y en refrigeración, por el contrario, con una transmitancia alta, factor solar bajo y transmisión luminosa alta, por lo que es la combinación de ambas estaciones la que dicta los valores óptimos. En iluminación, un menor consumo se obtiene con la transmisión luminosa y factor solar mayores.Office buildings in Spain represent 33% of the total energy consumption of building stock. Most were built prior to when the Technical Building Code came into force, and hence are not energy efficient and have highly glazed façades. Doors and windows are normally the first elements to be replaced during building renovations and present an opportunity for improvement. To this end, glazing can be analyzed according to its configuration, along with any internal coatings, i.e. with or without a low emissivity layer, and through the characteristic parameters, including: thermal transmittance, solar heat gain coefficient and visible transmittance. This article analyzes the replacement of monolithic glass panes with double panes without coatings (low emissivity), by orientation. Three Mediterranean climates with different winter and summer weather severity were studied in Spain (Barcelona, Seville and Malaga). In terms of window configuration and internal coatings, for heating, lower energy consumption can be obtained with glass without coatings that has higher thermal transmittance, and for cooling, with low emissivity glass. Alternately, if the characteristic parameters are analyzed, lower heating consumption is achieved with low thermal transmittance, high solar heat gain and low visible transmittance. On the contrary, during the summer high thermal transmittance, low solar heat gain coefficient and high visible transmittance yield the best results for cooling. Therefore, it is the combination of weather from both seasons that dictates the optimal values. In lighting, lower consumption is obtained with higher visible transmittance and solar heat gain coefficients

    Business plan for the feasibility study of a service and consulting company in real estate products, in the city of Bogotá

    Get PDF
    El presente documento presenta un plan de negocio con énfasis en asesoría integral en finca raíz (Inmuebles en venta y renta, asesorías jurídicas, remodelaciones y decoración de interiores), integra un análisis cuantitativo a partir de la recolección de datos por medio de encuestas para validar el segmento de mercado objetivo. Se obtuvo que los estratos socioeconómicos 4,5 y 6 en las localidades de Suba, Chapinero y Usaquén son el mercado objetivo en el cual se centrará las unidades de negocio que se proponen, se requieren clientes con un nivel sociocultural y poder adquisitivo alto dispuestos a adquirir los servicios propuestos. Es un proyecto de emprendimiento que socialmente genera empleo y apoya el crecimiento económico del país, se busca realizar proyectos amigables con el medio ambiente y que sean auto sostenibles. Realizando el análisis financiero, es un proyecto viable con indicadores positivos y acordes para posibles inversionistas que demuestren interés en este proyecto.This document presents a business plan with emphasis on comprehensive advice in real estate (Properties for sale and rent, legal advice, remodeling and interior decoration), integrates a quantitative analysis from the collection of data through surveys to validate the target market segment. It was obtained that the socioeconomic strata 4,5 and 6 in the towns of Suba, Chapinero and Usaquén are the target market in which the proposed business units will focus, clients with a sociocultural level and high purchasing power willing to acquire the proposed services. It is an entrepreneurial project that socially generates employment and supports the economic growth of the country, it seeks to carry out projects that are friendly to the environment and that are self-sustainable. Performing the financial analysis, it is a viable project with positive and consistent indicators for potential investors who show interest in this project.Magíster en Gerencia de ProyectosMaestrí

    Caracterización de menores víctimas en presuntos delitos sexuales

    Get PDF
    A descriptive cross-sectional study was conducted during the period from January 2013 to February 2014 with 92 alleged victims who met the inclusion criteria of interest in the study to which they filled out a form for collecting primary data prior informed consent of parents or guardians The objectives included characterizing sexual offenses in alleged victims under 16 years old in the province of Villa Clara and identify demographic and situational variables related to sexual offense type. The data processing was carried out through the creation of a database with a data processor (SPSS for Windows, version 11.0) system. The information is summarized in tables that reflect the absolute values ​​and percentages and survey techniques were used as descriptive type hypothesis testing between proportions, the goodness of fit to a theoretical approach and dependency between variables. It was found that the most common crime was lewd sexual abuse and the largest number of victims were female, aged between 11 and 15 years, the municipalities with the highest number of cases were Santa Clara, followed by Manicaragua and Sagua la Grande, crimes occurred, mostly in the author's home and victimizers  more predominant were neighbors and relatives.Se realizó un estudio descriptivo de corte transversal durante el período comprendido entre enero de 2013 hasta febrero de 2014 con 92 presuntas víctimas que cumplieron con los criterios de inclusión de interés en el estudio a las que se les llenó un formulario para recogida del dato primario previo consentimiento informado de padres o tutores. Los objetivos trazados incluyeron caracterizar los delitos sexuales en presuntas víctimas menores de 16 años en la Provincia de Villa Clara e identificar las variables de tipo demográficas y circunstanciales del hecho relacionadas con el tipo de delito sexual. El procesamiento de los datos se realizó a través de la creación de una base de datos con un sistema procesador de datos (SPSS para Windows, versión 11.0). La información se resumió en tablas que reflejan los valores absolutos y los por cientos y se utilizaron técnicas de estudio de tipo descriptivas como la prueba de hipótesis entre proporciones, la de bondad de ajuste a un planteamiento teórico y la de dependencia entre variables. Se constató que el delito sexual más frecuente fue el abuso lascivo y el mayor número de víctimas fueron femeninas, con edades comprendidas entre 11 y 15 años, los municipios que mayor número de casos aportaron fueron Santa Clara, seguido de Manicaragua y Sagua la Grande, los delitos se produjeron, en su mayoría, en el domicilio del autor y los victimarios que más predominaron fueron vecinos y familiares

    La educación ambiental y su impacto. Experiencias de la Universidad Politécnica Salesiana

    Get PDF
    La Universidad Politécnica Salesiana del Ecuador, fundada en 1994, es una institución de educación superior humanística y politécnica, de inspiración cristiana con carácter católico y carisma salesiano. Se dirige de manera preferencial a jóvenes de los grupos de menores ingresos, y fiel a su misión busca formar “ciudadanos honestos y buenos cristianos”, con excelencia académica y humana, con capacidades investigativas e innovadoras que contribuyan al “desarrollo sostenible local y nacional”. Su visión es ser una institución de educación superior reconocida por buscar la verdad, desarrollar la cultura y promover la investigación científica y tecnológica; reconocida socialmente por su excelencia académica, producción científica, responsabilidad social universitaria y por su capacidad de incidir en la innovación, la intercultural y el desarrollo. A través de sus funciones históricas y fundamentales: docencia, investigación y vinculación con la sociedad; la universidad trabaja para fortalecer el desarrollo del país y mejorar la calidad de vida de sus habitantes. Asume una participación efectiva con los actores sociales, demandando una responsabilidad social universitaria mediante programas y proyectos que responden a los actuales contextos de aguda pobreza, inequidad, injusticia, violencia, migración, emergencia sanitaria y vulneración de los derechos humanos

    Multi-Omics Integration Highlights the Role of Ubiquitination in CCl4-Induced Liver Fibrosis

    Get PDF
    Liver fibrosis is the excessive accumulation of extracellular matrix proteins that occurs in chronic liver disease. Ubiquitination is a post-translational modification that is crucial for a plethora of physiological processes. Even though the ubiquitin system has been implicated in several human diseases, the role of ubiquitination in liver fibrosis remains poorly understood. Here, multi-omics approaches were used to address this. Untargeted metabolomics showed that carbon tetrachloride (CCl4)-induced liver fibrosis promotes changes in the hepatic metabolome, specifically in glycerophospholipids and sphingolipids. Gene ontology analysis of public deposited gene array-based data and validation in our mouse model showed that the biological process “protein polyubiquitination” is enriched after CCl4-induced liver fibrosis. Finally, by using transgenic mice expressing biotinylated ubiquitin (bioUb mice), the ubiquitinated proteome was isolated and characterized by mass spectrometry in order to unravel the hepatic ubiquitinated proteome fingerprint in CCl4-induced liver fibrosis. Under these conditions, ubiquitination appears to be involved in the regulation of cell death and survival, cell function, lipid metabolism, and DNA repair. Finally, ubiquitination of proliferating cell nuclear antigen (PCNA) is induced during CCl4-induced liver fibrosis and associated with the DNA damage response (DDR). Overall, hepatic ubiquitome profiling can highlight new therapeutic targets for the clinical management of liver fibrosis.This work was supported by grants from Gobierno Vasco-Departamento de Salud 2013111114 (to M.L.M.-C.), ELKARTEK 2016, Departamento de Industria del Gobierno Vasco (to M.L.M.-C.), Ministerio de Ciencia, Innovación y Universidades MICINN: SAF2017-87301-R, SAF2017-88041-R, RTI2018-096759-A-100 and SAF2016-76898-P integrado en el Plan Estatal de Investigación Cientifica y Técnica y Innovación, cofinanciado con Fondos FEDER (to M.L.M.-C., J.M.M., T.C.D. and U.M. respectively); AECC Bizkaia (M.S.-M.); Asociación Española contra el Cáncer (T.C.D.), Fundación Científica de la Asociación Española Contra el Cancer (AECC Scientific Foundation) Rare Tumor Calls 2017 (to M.L.M., J.M.B., M.A.A., J.J.G.M.), La Caixa Foundation Program (to M.L.M.), 2018 BBVA Foundation Grants for Scientific Research Teams (to M.L.M.-C.). This research was also funded by the CIBERehd (EHD15PI05/2016) and “Fondo de Investigaciones Sanitarias, Instituto de Salud Carlos III”, Spain (PI16/00598 and PI19/00819, co-funded by European Regional Development Fund/European Social Fund, “Investing in your future”); Spanish Ministry of Economy, Industry and Competitiveness (SAF2016-75197-R); “Junta de Castilla y Leon” (SA063P17); AECC Scientific Foundation (2017/2020), Spain; “Centro Internacional sobre el Envejecimiento” (OLD-HEPAMARKER, 0348_CIE_6_E), Spain; University of Salamanca Foundation, Spain (PC-TCUE18-20_051), and Fundació Marato TV3 (Ref. 201916-31), Spain (to J.J.G.M.). The UPV/EHU Lab and the Proteomics Platform are members of Proteored, PRB3 and is supported by grant PT17/0019, of the PE I + D + i 2013-2016, funded by ISCIII and ERDF. Ciberehd_ISCIII_MINECO is funded by the Instituto de Salud Carlos III. We thank MINECO for the Severo Ochoa Excellence Accreditation to CIC bioGUNE (SEV-2016-0644)

    The outcome of boosting mitochondrial activity in alcohol-associated liver disease is organ-dependent.

    Get PDF
    BACKGROUND AND AIMS Alcohol-associated liver disease (ALD) accounts for 70% of liver-related deaths in Europe, with no effective approved therapies. Although mitochondrial dysfunction is one of the earliest manifestations of alcohol-induced injury, restoring mitochondrial activity remains a problematic strategy due to oxidative stress. Here, we identify methylation-controlled J protein (MCJ) as a mediator for ALD progression and hypothesize that targeting MCJ may help in recovering mitochondrial fitness without collateral oxidative damage. APPROACH AND RESULTS C57BL/6 mice [wild-type (Wt)] Mcj knockout and Mcj liver-specific silencing (MCJ-LSS) underwent the NIAAA dietary protocol (Lieber-DeCarli diet containing 5% (vol/vol) ethanol for 10 days, plus a single binge ethanol feeding at day 11). To evaluate the impact of a restored mitochondrial activity in ALD, the liver, gut, and pancreas were characterized, focusing on lipid metabolism, glucose homeostasis, intestinal permeability, and microbiota composition. MCJ, a protein acting as an endogenous negative regulator of mitochondrial respiration, is downregulated in the early stages of ALD and increases with the severity of the disease. Whole-body deficiency of MCJ is detrimental during ALD because it exacerbates the systemic effects of alcohol abuse through altered intestinal permeability, increased endotoxemia, and dysregulation of pancreatic function, which overall worsens liver injury. On the other hand, liver-specific Mcj silencing prevents main ALD hallmarks, that is, mitochondrial dysfunction, steatosis, inflammation, and oxidative stress, as it restores the NAD + /NADH ratio and SIRT1 function, hence preventing de novo lipogenesis and improving lipid oxidation. CONCLUSIONS Improving mitochondrial respiration by liver-specific Mcj silencing might become a novel therapeutic approach for treating ALD.This work was supported by grants from Ministerio de Ciencia e Innovación, Programa Retos-Colaboración RTC2019-007125-1 (for Jorge Simon and Maria Luz Martinez-Chantar); Ministerio de Economía, Industria y Competitividad, Retos a la Sociedad AGL2017- 86927R (for F.M.); Instituto de Salud Carlos III, Proyectos de Investigación en Salud DTS20/00138 and DTS21/00094 (for Jorge Simon and Maria Luz Martinez-Chantar, and Asis Palazon. respectively); Instituto de Salud Carlos III, Fondo de Investigaciones Sanitarias co-founded by European Regional Development Fund/European Social Fund, “Investing in your future” PI19/00819, “Una manera de hacer Europa” FIS PI20/00765, and PI21/01067 (for Jose J. G. Marin., Pau Sancho-Bru,. and Mario F. Fraga respectively); Departamento de Industria del Gobierno Vasco (for Maria Luz Martinez-Chantar); Asturias Government (PCTI) co-funding 2018-2023/ FEDER IDI/2021/000077 (for Mario F. Fraga.); Ministerio de Ciencia, Innovación y Universidades MICINN: PID2020-117116RB-I00, CEX2021-001136-S PID2020-117941RB-I00, PID2020-11827RB-I00 and PID2019-107956RA-100 integrado en el Plan Estatal de Investigación Científica y Técnica y Innovación, cofinanciado con Fondos FEDER (for Maria Luz Martinez-Chantar, Francisco J Cubero., Yulia A Nevzorova and Asis Palazon); Ayudas Ramón y Cajal de la Agencia Estatal de Investigación RY2013-13666 and RYC2018- 024183-I (for Leticia Abecia and Asis Palazon); European Research Council Starting Grant 804236 NEXTGEN-IO (for Asis Palazon); The German Research Foundation SFB/TRR57/P04, SFB1382-403224013/ A02 and DFG NE 2128/2-1 (for Francisco J Cubero and Yulia A Nevzorova); National Institute of Health (NIH)/National Institute of Alcohol Abuse and Alcoholism (NIAAA) 1U01AA026972-01 (For Pau Sancho-Bru); Junta de Castilla y León SA074P20 (for Jose J. G. Marin); Junta de Andalucía, Grupo PAIDI BIO311 (for Franz Martin); CIBERER Acciones Cooperativas y Complementarias Intramurales ACCI20-35 (for Mario F. Fraga); Ministerio de Educación, Cultura y Deporte FPU17/04992 (for Silvia Ariño); Fundació Marato TV3 201916-31 (for Jose J. G. Marin.); Ainize Pena-Cearra is a fellow of the University of the Basque Country (UPV/ EHU); BIOEF (Basque Foundation for Innovation and Health Research); Asociación Española contra el Cáncer (Maria Luz Martinez-Chantar and Teresa C. Delgado.); Fundación Científica de la Asociación Española Contra el Cáncer (AECC Scientific Foundation) Rare Tumor Calls 2017 (for Maria Luz Martinez-Chantar); La Caixa Foundation Program (for Maria Luz Martinez-Chantar); Proyecto Desarrollo Tecnologico CIBERehd (for Maria Luz Martinez-Chantar); Ciberehd_ISCIII_MINECO is funded by the Instituto de Salud Carlos III.S

    Effect of viral storm in patients admitted to intensive care units with severe COVID-19 in Spain: a multicentre, prospective, cohort study

    Get PDF
    Background: The contribution of the virus to the pathogenesis of severe COVID-19 is still unclear. We aimed to evaluate associations between viral RNA load in plasma and host response, complications, and deaths in critically ill patients with COVID-19. Methods: We did a prospective cohort study across 23 hospitals in Spain. We included patients aged 18 years or older with laboratory-confirmed SARS-CoV-2 infection who were admitted to an intensive care unit between March 16, 2020, and Feb 27, 2021. RNA of the SARS-CoV-2 nucleocapsid region 1 (N1) was quantified in plasma samples collected from patients in the first 48 h following admission, using digital PCR. Patients were grouped on the basis of N1 quantity: VIR-N1-Zero ([removed]2747 N1 copies per mL). The primary outcome was all-cause death within 90 days after admission. We evaluated odds ratios (ORs) for the primary outcome between groups using a logistic regression analysis. Findings: 1068 patients met the inclusion criteria, of whom 117 had insufficient plasma samples and 115 had key information missing. 836 patients were included in the analysis, of whom 403 (48%) were in the VIR-N1-Low group, 283 (34%) were in the VIR-N1-Storm group, and 150 (18%) were in the VIR-N1-Zero group. Overall, patients in the VIR-N1-Storm group had the most severe disease: 266 (94%) of 283 patients received invasive mechanical ventilation (IMV), 116 (41%) developed acute kidney injury, 180 (65%) had secondary infections, and 148 (52%) died within 90 days. Patients in the VIR-N1-Zero group had the least severe disease: 81 (54%) of 150 received IMV, 34 (23%) developed acute kidney injury, 47 (32%) had secondary infections, and 26 (17%) died within 90 days (OR for death 0·30, 95% CI 0·16–0·55; p<0·0001, compared with the VIR-N1-Storm group). 106 (26%) of 403 patients in the VIR-N1-Low group died within 90 days (OR for death 0·39, 95% CI 0·26–0·57; p[removed]11 página
    corecore