7,236 research outputs found
Mesh-to-raster based non-rigid registration of multi-modal images
Region of interest (ROI) alignment in medical images plays a crucial role in
diagnostics, procedure planning, treatment, and follow-up. Frequently, a model
is represented as triangulated mesh while the patient data is provided from CAT
scanners as pixel or voxel data. Previously, we presented a 2D method for
curve-to-pixel registration. This paper contributes (i) a general
mesh-to-raster (M2R) framework to register ROIs in multi-modal images; (ii) a
3D surface-to-voxel application, and (iii) a comprehensive quantitative
evaluation in 2D using ground truth provided by the simultaneous truth and
performance level estimation (STAPLE) method. The registration is formulated as
a minimization problem where the objective consists of a data term, which
involves the signed distance function of the ROI from the reference image, and
a higher order elastic regularizer for the deformation. The evaluation is based
on quantitative light-induced fluoroscopy (QLF) and digital photography (DP) of
decalcified teeth. STAPLE is computed on 150 image pairs from 32 subjects, each
showing one corresponding tooth in both modalities. The ROI in each image is
manually marked by three experts (900 curves in total). In the QLF-DP setting,
our approach significantly outperforms the mutual information-based
registration algorithm implemented with the Insight Segmentation and
Registration Toolkit (ITK) and Elastix
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions
3-D Face Analysis and Identification Based on Statistical Shape Modelling
This paper presents an effective method of statistical shape representation for automatic face analysis and identification in 3-D. The method combines statistical shape modelling techniques and the non-rigid deformation matching scheme. This work is distinguished by three key contributions. The first is the introduction of a new 3-D shape registration method using hierarchical landmark detection and multilevel B-spline warping technique, which allows accurate dense correspondence search for statistical model construction. The second is the shape representation approach, based on Laplacian Eigenmap, which provides a nonlinear submanifold that links underlying structure of facial data. The third contribution is a hybrid method for matching the statistical model and test dataset which controls the levels of the model’s deformation at different matching stages and so increases chance of the successful matching. The proposed method is tested on the public database, BU-3DFE. Results indicate that it can achieve extremely high verification rates in a series of tests, thus providing real-world practicality
LiveCap: Real-time Human Performance Capture from Monocular Video
We present the first real-time human performance capture approach that
reconstructs dense, space-time coherent deforming geometry of entire humans in
general everyday clothing from just a single RGB video. We propose a novel
two-stage analysis-by-synthesis optimization whose formulation and
implementation are designed for high performance. In the first stage, a skinned
template model is jointly fitted to background subtracted input video, 2D and
3D skeleton joint positions found using a deep neural network, and a set of
sparse facial landmark detections. In the second stage, dense non-rigid 3D
deformations of skin and even loose apparel are captured based on a novel
real-time capable algorithm for non-rigid tracking using dense photometric and
silhouette constraints. Our novel energy formulation leverages automatically
identified material regions on the template to model the differing non-rigid
deformation behavior of skin and apparel. The two resulting non-linear
optimization problems per-frame are solved with specially-tailored
data-parallel Gauss-Newton solvers. In order to achieve real-time performance
of over 25Hz, we design a pipelined parallel architecture using the CPU and two
commodity GPUs. Our method is the first real-time monocular approach for
full-body performance capture. Our method yields comparable accuracy with
off-line performance capture techniques, while being orders of magnitude
faster
Atlas-Based Prostate Segmentation Using an Hybrid Registration
Purpose: This paper presents the preliminary results of a semi-automatic
method for prostate segmentation of Magnetic Resonance Images (MRI) which aims
to be incorporated in a navigation system for prostate brachytherapy. Methods:
The method is based on the registration of an anatomical atlas computed from a
population of 18 MRI exams onto a patient image. An hybrid registration
framework which couples an intensity-based registration with a robust
point-matching algorithm is used for both atlas building and atlas
registration. Results: The method has been validated on the same dataset that
the one used to construct the atlas using the "leave-one-out method". Results
gives a mean error of 3.39 mm and a standard deviation of 1.95 mm with respect
to expert segmentations. Conclusions: We think that this segmentation tool may
be a very valuable help to the clinician for routine quantitative image
exploitation.Comment: International Journal of Computer Assisted Radiology and Surgery
(2008) 000-99
- …