14,746 research outputs found
Out-Of-Focus Holography at the Green Bank Telescope
We describe phase-retrieval holography measurements of the 100-m diameter
Green Bank Telescope using astronomical sources and an astronomical receiver
operating at a wavelength of 7 mm. We use the technique with parameterization
of the aperture in terms of Zernike polynomials and employing a large defocus,
as described by Nikolic, Hills & Richer (2006). Individual measurements take
around 25 minutes and from the resulting beam maps (which have peak signal to
noise ratios of 200:1) we show that it is possible to produce low-resolution
maps of the wavefront errors with accuracy around a hundredth of a wavelength.
Using such measurements over a wide range of elevations, we have calculated a
model for the wavefront-errors due to the uncompensated gravitational
deformation of the telescope. This model produces a significant improvement at
low elevations, where these errors are expected to be the largest; after
applying the model, the aperture efficiency is largely independent of
elevation. We have also demonstrated that the technique can be used to measure
and largely correct for thermal deformations of the antenna, which often exceed
the uncompensated gravitational deformations during daytime observing.
We conclude that the aberrations induced by gravity and thermal effects are
large-scale and the technique used here is particularly suitable for measuring
such deformations in large millimetre wave radio telescopes.Comment: 10 pages, 7 figures (accepted by Astronomy & Astrophysics
Energy-based trajectory tracking and vibration control for multilink highly flexible manipulators
In this paper, a discrete model is adopted, as proposed by Hencky for elastica based on rigid bars and lumped rotational springs, to design the control of a lightweight planar manipulator with multiple highly flexible links. This model is particularly suited to deal with nonlinear equations of motion as those associated with multilink robot arms, because it does not include any simplification due to linearization, as in the assumed modes method. The aim of the control is to track a trajectory of the end effector of the robot arm, without the onset of vibrations. To this end, an energy-based method is proposed. Numerical simulations show the effectiveness of the presented approach
Prostate Biopsy Assistance System with Gland Deformation Estimation for Enhanced Precision
Computer-assisted prostate biopsies became a very active research area during
the last years. Prostate tracking makes it possi- ble to overcome several
drawbacks of the current standard transrectal ultrasound (TRUS) biopsy
procedure, namely the insufficient targeting accuracy which may lead to a
biopsy distribution of poor quality, the very approximate knowledge about the
actual location of the sampled tissues which makes it difficult to implement
focal therapy strategies based on biopsy results, and finally the difficulty to
precisely reach non-ultrasound (US) targets stemming from different modalities,
statistical atlases or previous biopsy series. The prostate tracking systems
presented so far are limited to rigid transformation tracking. However, the
gland can get considerably deformed during the intervention because of US probe
pres- sure and patient movements. We propose to use 3D US combined with
image-based elastic registration to estimate these deformations. A fast elastic
registration algorithm that copes with the frequently occurring US shadows is
presented. A patient cohort study was performed, which yielded a statistically
significant in-vivo accuracy of 0.83+-0.54mm.Comment: This version of the paper integrates a correction concerning the
local similarity measure w.r.t. the proceedings (this typing error could not
be corrected before editing the proceedings
Range-dependent flexibility in the acoustic field of view of echolocating porpoises (Phocoena phocoena)
Funding: Det Frie Forskningsrad (MJ)Toothed whales use sonar to detect, locate, and track prey. They adjust emitted sound intensity, auditory sensitivity and click rate to target range, and terminate prey pursuits with high-repetition-rate, low-intensity buzzes. However, their narrow acoustic field of view (FOV) is considered stable throughout target approach, which could facilitate prey escape at close-range. Here we show that, like some bats, harbour porpoises can broaden their biosonar beam during the terminal phase of attack but, unlike bats, maintain the ability to change beamwidth within this phase. Based on video, MRI, and acoustic-tag recordings, we propose this flexibility is modulated by the melon and implemented to accommodate dynamic spatial relationships with prey and acoustic complexity of surroundings. Despite independent evolution and different means of sound generation and transmission, whales and bats adaptively change their FOV, suggesting that beamwidth flexibility has been an important driver in the evolution of echolocation for prey tracking.Publisher PDFPeer reviewe
Evaluation of the ALMA Prototype Antennas
The ALMA North American and European prototype antennas have been evaluated
by a variety of measurement systems to quantify the major performance
specifications. Nearfield holography was used to set the reflector surfaces to
17 microns RMS. Pointing and fast switching performance was determined with an
optical telescope and by millimeter wavelength radiometry, yielding 2 arcsec
absolute and 0.6 arcsec offset pointing accuracies. Path length stability was
measured to be less than or approximately equal to 20 microns over 10 minute
time periods using optical measurement devices. Dynamical performance was
studied with a set of accelerometers, providing data on wind induced tracking
errors and structural deformation. Considering all measurements made during
this evaluation, both prototype antennas meet the major ALMA antenna
performance specifications.Comment: 83 pages, 36 figures, AASTex format, to appear in PASP September 2006
issu
Recommended from our members
Respiration-Induced Intraorgan Deformation of the Liver: Implications for Treatment Planning in Patients Treated With Fiducial Tracking.
Stereotactic body radiation therapy is a well-tolerated modality for the treatment of primary and metastatic liver lesions, and fiducials are often used as surrogates for tumor tracking during treatment. We evaluated respiratory-induced liver deformation by measuring the rigidity of the fiducial configuration during the breathing cycle. Seventeen patients, with 18 distinct treatment courses, were treated with stereotactic body radiosurgery using multiple fiducials. Liver deformation was empirically quantified by measuring the intrafiducial distances at different phases of respiration. Data points were collected at the 0%, 50%, and 100% inspiration points, and the distance between each pair of fiducials was measured at the 3 phases. The rigid body error was calculated as the maximum difference in the intrafiducial distances. Liver disease was calculated with Child-Pugh score using laboratory values within 3 months of initiation of treatment. A peripheral fiducial was defined as within 1.5 cm of the liver edge, and all other fiducials were classified as central. For 5 patients with only peripheral fiducials, the fiducial configuration had more deformation (average maximum rigid body error 7.11 mm, range: 1.89-11.35 mm) when compared to patients with both central and peripheral and central fiducials only (average maximum rigid body error 3.36 mm, range: 0.5-9.09 mm, P = .037). The largest rigid body errors (11.3 and 10.6 mm) were in 2 patients with Child-Pugh class A liver disease and multiple peripheral fiducials. The liver experiences internal deformation, and the fiducial configuration should not be assumed to act as a static structure. We observed greater deformation at the periphery than at the center of the liver. In our small data set, we were not able to identify cirrhosis, which is associated with greater rigidity of the liver, as predictive for deformation. Treatment planning based only on fiducial localization must take potential intraorgan deformation into account
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It
shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible
modifications arising during this process
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large
spectrometer magnets of the PANDA detector set-up. It shows the conceptual
design of the magnets and their anticipated performance. It precedes the tender
and procurement of the magnets and, hence, is subject to possible modifications
arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti
Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski,
Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy),
Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy
The Cosmic Background Imager
Design and performance details are given for the Cosmic Background Imager
(CBI), an interferometer array that is measuring the power spectrum of
fluctuations in the cosmic microwave background radiation (CMBR) for multipoles
in the range 400 < l < 3500. The CBI is located at an altitude of 5000 m in the
Atacama Desert in northern Chile. It is a planar synthesis array with 13 0.9-m
diameter antennas on a 6-m diameter tracking platform. Each antenna has a
cooled, low-noise receiver operating in the 26-36 GHz band. Signals are
cross-correlated in an analog filterbank correlator with ten 1 GHz bands. This
allows spectral index measurements which can be used to distinguish CMBR
signals from diffuse galactic foregrounds. A 1.2 kHz 180-deg phase switching
scheme is used to reject cross-talk and low-frequency pick-up in the signal
processing system. The CBI has a 3-axis mount which allows the tracking
platform to be rotated about the optical axis, providing improved (u,v)
coverage and a powerful discriminant against false signals generated in the
receiving electronics. Rotating the tracking platform also permits polarization
measurements when some of the antennas are configured for the orthogonal
polarization.Comment: 14 pages. Accepted for publication in PASP. See also
http://www.astro.caltech.edu/~tjp/CBI
- …