2,141 research outputs found

    Binary time series classification with Bayesian convolutional neural networks when monitoring for marine gas discharges

    Get PDF
    The world’s oceans are under stress from climate change, acidification and other human activities, and the UN has declared 2021–2030 as the decade for marine science. To monitor the marine waters, with the purpose of detecting discharges of tracers from unknown locations, large areas will need to be covered with limited resources. To increase the detectability of marine gas seepage we propose a deep probabilistic learning algorithm, a Bayesian Convolutional Neural Network (BCNN), to classify time series of measurements. The BCNN will classify time series to belong to a leak/no-leak situation, including classification uncertainty. The latter is important for decision makers who must decide to initiate costly confirmation surveys and, hence, would like to avoid false positives. Results from a transport model are used for the learning process of the BCNN and the task is to distinguish the signal from a leak hidden within the natural variability. We show that the BCNN classifies time series arising from leaks with high accuracy and estimates its associated uncertainty. We combine the output of the BCNN model, the posterior predictive distribution, with a Bayesian decision rule showcasing how the framework can be used in practice to make optimal decisions based on a given cost function.publishedVersio

    Water Pipeline Leakage Detection Based on Machine Learning and Wireless Sensor Networks

    Get PDF
    The detection of water pipeline leakage is important to ensure that water supply networks can operate safely and conserve water resources. To address the lack of intelligent and the low efficiency of conventional leakage detection methods, this paper designs a leakage detection method based on machine learning and wireless sensor networks (WSNs). The system employs wireless sensors installed on pipelines to collect data and utilizes the 4G network to perform remote data transmission. A leakage triggered networking method is proposed to reduce the wireless sensor network’s energy consumption and prolong the system life cycle effectively. To enhance the precision and intelligence of leakage detection, we propose a leakage identification method that employs the intrinsic mode function, approximate entropy, and principal component analysis to construct a signal feature set and that uses a support vector machine (SVM) as a classifier to perform leakage detection. Simulation analysis and experimental results indicate that the proposed leakage identification method can effectively identify the water pipeline leakage and has lower energy consumption than the networking methods used in conventional wireless sensor networks

    Robust leak localization in water distribution networks using machine learning techniques

    Get PDF
    This PhD thesis presents a methodology to detect, estimate and localize water leaks (with the main focus in the localization problem) in water distribution networks using hydraulic models and machine learning techniques. The actual state of the art is introduced, the theoretical basis of the machine learning techniques applied are explained and the hydraulic model is also detailed. The whole methodology is presented and tested into different water distribution networks and district metered areas based on simulated and real case studies and compared with published methods. The focus of the contributions is to bring more robust methods against the uncertainties that effects the problem of leak detection, by dealing with them using the self-similarity to create features monitored by the change detection technique intersection-of-confidence-interval, and the leak localization where the problem is tackled using machine learning techniques. By using those techniques, it is expected to learn the leak behavior considering their uncertainty to be used in the diagnosis stage after the training phase. One method for the leak detection problem is presented that is able to estimate the leak size and the time that the leak has been produced. This method captures the normal, leak-free, behavior and contrast it with the new measurements in order to evaluate the state of the network. If the behavior is not normal check if it is due to a leak. To have a more robust leak detection method, a specific validation is designed to operate specifically with leaks and in the temporal region where the leak is most apparent. A methodology to extent the current model-based approach to localize water leaks by means of classifiers is proposed where the non-parametric k-nearest neighbors classifier and the parametric multi-class Bayesian classifier are proposed. A new data-driven approach to localize leaks using a multivariate regression technique without the use of hydraulic models is also introduced. This method presents a clear benefit over the model-based technique by removing the need of the hydraulic model despite of the topological information is still required. Also, the information of the expected leaks is not required since information of the expected hydraulic behavior with leak is exploited to find the place where the leak is more suitable. This method has a good performance in practice, but is very sensitive to the number of sensor in the network and their sensor placement. The proposed sensor placement techniques reduce the computational load required to take into account the amount of data needed to model the uncertainty compared with other optimization approaches while are designed to work with the leak localization problem. More precisely, the proposed hybrid feature selection technique for sensor placement is able to work with any method that can be evaluated with confusion matrix and still being specialized for the leak localization task. This last method is good for a few sensors, but lacks of precision when the number of sensors to place is large. To overcome this problem an incremental sensor placement is proposed which is better for a larger number of sensors to place but worse when the number is small.Aquesta tesi presenta una nova metodologia per a localització de fuites en xarxes de distribució d'aigua potable. Primer s'ha revisat l'estat del art actual i les bases teòriques tant de les tècniques de machine learning utilitzades al llarg de la tesi com els mètodes existents de localització de fuites. La metodologia presentada s'ha provat en diferents xarxes d'aigua simulades i reals, comparant el resultats amb altres mètodes publicats. L'objectiu principal de la contribució aportada és el de desenvolupar mètodes més robustos enfront les incerteses que afecten a la localització de fuites. En el cas de la detecció i estimació de la magnitud de la fuita, s'utilitza la tècnica self-similarity per crear els indicadors es monitoritzen amb la tècnica de detecció de canvis ("intersection-of-confidence-intervals"). En el cas de la localització de les fuites, s'han fet servir les tècniques de classificadors i interpoladors provinents del machine learning. A l'utilitzar aquestes tècniques s'espera captar el comportament de la fuita i de la incertesa per aprendre i tenir-ho en compte en la fase de la localització de la fuita. El mètode de la detecció de fallades proposat és capaç d'estimar la magnitud de la fuita i l'instant en que s'ha produït. Aquest mètode captura el comportament normal, sense fuita, i el contrasta amb les noves mesures per avaluar l'estat de la xarxa. En el cas que el comportament no sigui el normal, es procedeix a comprovar si això és degut a una fuita. Per tenir una mètode de detecció més robust, es fa servir una capa de validació especialment dissenyada per treballar específicament amb fuites i en la regió temporal en que la fuita és més evident. Per tal de millorar l'actual metodologia de localització de fuites mitjançant models hidràulics s'ha proposat l'ús de classificadors. Per una banda es proposa el classificador no paramètric k-nearest neighbors i per l'altre banda el classificador Bayesià paramètric per múltiples classes. Finalment, s'ha desenvolupat un nou mètode de localització de fuites basat en models de dades mitjançant la regressió de múltiples paràmetres sense l'ús del model hidràulic de la xarxa. Finalment, s'ha tractat el problema de la col·locació de sensors. El rendiment de la localització de fuites està relacionada amb la col·locació de sensors i és particular per a cada mètode de localització. Amb l'objectiu de maximitzar el rendiment dels mètodes de localització de fuites presentats anteriorment, es presenten i avaluen tècniques de col·locació de sensors específicament dissenyats ja que el problema de combinatòria no es pot manejar intentant cada possible combinació de sensors a part de les xarxes més petites amb pocs sensors per instal·lar. Aquestes tècniques de col·locació de sensors exploten el potencial de les tècniques de selecció de variables per tal de realitzar la tasca desitjada.Esta tesis doctoral presenta una nueva metodología para detectar, estimar el tamaño y localizar fugas de agua (donde el foco principal está puesto en el problema de la localización de fugas) en redes de distribución de agua potable. La tesis presenta una revisión del estado actual y las bases de las técnicas de machine learning que se aplican, así como una explicación del modelo hidráulico de las redes de agua. El conjunto de la metodología se presenta y prueba en diferentes redes de distribución de agua y sectores de consumo con casos de estudio simulados y reales, y se compara con otros métodos ya publicados. La contribución principal es la de desarrollar métodos más robustos frente a la incertidumbre de los datos. En la detección de fugas, la incertidumbre se trata con la técnica del self-similarity para la generación de indicadores que luego son monitoreados per la técnica de detección de cambios conocida como intersection-of-confidece-interval. En la localización de fugas el problema de la incertidumbre se trata con técnicas de machine learning. Al utilizar estas técnicas se espera aprender el comportamiento de la fuga y su incertidumbre asociada para tenerlo en cuenta en la fase de diagnóstico. El método presentado para la detección de fugas tiene la habilidad de estimar la magnitud y el instante en que la fuga se ha producido. Este método captura el comportamiento normal, sin fugas, del sistema y lo contrasta con las nuevas medidas para evaluar el estado actual de la red. En el caso de que el comportamiento no sea el normal, se comprueba si es debido a la presencia de una fuga en el sistema. Para obtener un método de detección más robusto, se considera una capa de validación especialmente diseñada para trabajar específicamente con fugas y durante el periodo temporal donde la fuga es más evidente. Esta técnica se compara con otras ya publicadas proporcionando una detección más fiable, especialmente en el caso de fugas pequeñas, al mismo tiempo que proporciona más información que puede ser usada en la fase de la localización de la fuga permitiendo mejorarla. El principal problema es que el método es más lento que los otros métodos analizados. Con el fin de mejorar la actual metodología de localización de fugas mediante modelos hidráulicos, se propone la utilización de clasificadores. Concretamente, se propone el clasificador no paramétrico k-nearest neighbors y el clasificador Bayesiano paramétrico para múltiples clases. La propuesta de localización de fugas mediante modelos hidráulicos y clasificadores permite gestionar la incertidumbre de los datos mejor para obtener un diagnóstico de la localización de la fuga más preciso. El principal inconveniente recae en el coste computacional, aunque no se realiza en tiempo real, de los datos necesarios por el clasificador para aprender correctamente la dispersión de los datos. Además, el método es muy dependiente de la calidad del modelo hidráulico de la red. En el campo de la localización de fugas, se a propuesto un nuevo método de localización de fugas basado en modelos de datos mediante la regresión de múltiples parámetros sin el uso de modelo hidráulico. Este método presenta un claro beneficio respecto a las técnicas basadas en modelos hidráulicos ya que prescinde de su uso, aunque la información topológica de la red es aún necesaria. Además, la información del comportamiento de la red para cada fuga no es necesario, ya que el conocimiento del efecto hidráulico de una fuga en un determinado punto de la red es utilizado para la localización. Este método ha dado muy buenos resultados en la práctica, aunque es muy sensible al número de sensores y a su colocación en la red. Finalmente, se trata el problema de la colocación de sensores. El desempeño de la localización de fugas está ligado a la colocación de los sensores y es particular para cada método. Con el objetivo de maximizar el desempeño de los métodos de localización de fugas presentados, técnicas de colocación de sensores específicamente diseñados para ellos se han presentado y evaluado. Dado que el problema de combinatoria que presenta no puede ser tratado analizando todas las posibles combinaciones de sensores excepto en las redes más pequeñas con unos pocos sensores para instalar. Estas técnicas de colocación de sensores explotan el potencial de las técnicas de selección de variables para realizar la tarea deseada. Las técnicas de colocación de sensores propuestas reducen la carga computacional, requerida para tener en cuenta todos los datos necesarios para modelar bien la incertidumbre, comparado con otras propuestas de optimización al mismo tiempo que están diseñadas para trabajar en la tarea de la localización de fugas. Más concretamente, la propuesta basada en la técnica híbrida de selección de variables para la colocación de sensores es capaz de trabajar con cualquier técnica de localización de fugas que se pueda evaluar con la matriz de confusión y ser a la vez óptimo. Este método es muy bueno para la colocación de sensores, pero el rendimiento disminuye a medida que el número de sensores a colocar crece. Para evitar este problema, se propone método de colocación de sensores de forma incremental que presenta un mejor rendimiento para un número alto de sensores a colocar, aunque no es tan eficaz con pocos sensores a colocar

    Robust leak localization in water distribution networks using machine learning techniques

    Get PDF
    Aplicat embargament des de la data de lectura fins el 20 de desembre de 2019This PhD thesis presents a methodology to detect, estimate and localize water leaks (with the main focus in the localization problem) in water distribution networks using hydraulic models and machine learning techniques. The actual state of the art is introduced, the theoretical basis of the machine learning techniques applied are explained and the hydraulic model is also detailed. The whole methodology is presented and tested into different water distribution networks and district metered areas based on simulated and real case studies and compared with published methods. The focus of the contributions is to bring more robust methods against the uncertainties that effects the problem of leak detection, by dealing with them using the self-similarity to create features monitored by the change detection technique intersection-of-confidence-interval, and the leak localization where the problem is tackled using machine learning techniques. By using those techniques, it is expected to learn the leak behavior considering their uncertainty to be used in the diagnosis stage after the training phase. One method for the leak detection problem is presented that is able to estimate the leak size and the time that the leak has been produced. This method captures the normal, leak-free, behavior and contrast it with the new measurements in order to evaluate the state of the network. If the behavior is not normal check if it is due to a leak. To have a more robust leak detection method, a specific validation is designed to operate specifically with leaks and in the temporal region where the leak is most apparent. A methodology to extent the current model-based approach to localize water leaks by means of classifiers is proposed where the non-parametric k-nearest neighbors classifier and the parametric multi-class Bayesian classifier are proposed. A new data-driven approach to localize leaks using a multivariate regression technique without the use of hydraulic models is also introduced. This method presents a clear benefit over the model-based technique by removing the need of the hydraulic model despite of the topological information is still required. Also, the information of the expected leaks is not required since information of the expected hydraulic behavior with leak is exploited to find the place where the leak is more suitable. This method has a good performance in practice, but is very sensitive to the number of sensor in the network and their sensor placement. The proposed sensor placement techniques reduce the computational load required to take into account the amount of data needed to model the uncertainty compared with other optimization approaches while are designed to work with the leak localization problem. More precisely, the proposed hybrid feature selection technique for sensor placement is able to work with any method that can be evaluated with confusion matrix and still being specialized for the leak localization task. This last method is good for a few sensors, but lacks of precision when the number of sensors to place is large. To overcome this problem an incremental sensor placement is proposed which is better for a larger number of sensors to place but worse when the number is small.Aquesta tesi presenta una nova metodologia per a localització de fuites en xarxes de distribució d'aigua potable. Primer s'ha revisat l'estat del art actual i les bases teòriques tant de les tècniques de machine learning utilitzades al llarg de la tesi com els mètodes existents de localització de fuites. La metodologia presentada s'ha provat en diferents xarxes d'aigua simulades i reals, comparant el resultats amb altres mètodes publicats. L'objectiu principal de la contribució aportada és el de desenvolupar mètodes més robustos enfront les incerteses que afecten a la localització de fuites. En el cas de la detecció i estimació de la magnitud de la fuita, s'utilitza la tècnica self-similarity per crear els indicadors es monitoritzen amb la tècnica de detecció de canvis ("intersection-of-confidence-intervals"). En el cas de la localització de les fuites, s'han fet servir les tècniques de classificadors i interpoladors provinents del machine learning. A l'utilitzar aquestes tècniques s'espera captar el comportament de la fuita i de la incertesa per aprendre i tenir-ho en compte en la fase de la localització de la fuita. El mètode de la detecció de fallades proposat és capaç d'estimar la magnitud de la fuita i l'instant en que s'ha produït. Aquest mètode captura el comportament normal, sense fuita, i el contrasta amb les noves mesures per avaluar l'estat de la xarxa. En el cas que el comportament no sigui el normal, es procedeix a comprovar si això és degut a una fuita. Per tenir una mètode de detecció més robust, es fa servir una capa de validació especialment dissenyada per treballar específicament amb fuites i en la regió temporal en que la fuita és més evident. Per tal de millorar l'actual metodologia de localització de fuites mitjançant models hidràulics s'ha proposat l'ús de classificadors. Per una banda es proposa el classificador no paramètric k-nearest neighbors i per l'altre banda el classificador Bayesià paramètric per múltiples classes. Finalment, s'ha desenvolupat un nou mètode de localització de fuites basat en models de dades mitjançant la regressió de múltiples paràmetres sense l'ús del model hidràulic de la xarxa. Finalment, s'ha tractat el problema de la col·locació de sensors. El rendiment de la localització de fuites està relacionada amb la col·locació de sensors i és particular per a cada mètode de localització. Amb l'objectiu de maximitzar el rendiment dels mètodes de localització de fuites presentats anteriorment, es presenten i avaluen tècniques de col·locació de sensors específicament dissenyats ja que el problema de combinatòria no es pot manejar intentant cada possible combinació de sensors a part de les xarxes més petites amb pocs sensors per instal·lar. Aquestes tècniques de col·locació de sensors exploten el potencial de les tècniques de selecció de variables per tal de realitzar la tasca desitjada.Esta tesis doctoral presenta una nueva metodología para detectar, estimar el tamaño y localizar fugas de agua (donde el foco principal está puesto en el problema de la localización de fugas) en redes de distribución de agua potable. La tesis presenta una revisión del estado actual y las bases de las técnicas de machine learning que se aplican, así como una explicación del modelo hidráulico de las redes de agua. El conjunto de la metodología se presenta y prueba en diferentes redes de distribución de agua y sectores de consumo con casos de estudio simulados y reales, y se compara con otros métodos ya publicados. La contribución principal es la de desarrollar métodos más robustos frente a la incertidumbre de los datos. En la detección de fugas, la incertidumbre se trata con la técnica del self-similarity para la generación de indicadores que luego son monitoreados per la técnica de detección de cambios conocida como intersection-of-confidece-interval. En la localización de fugas el problema de la incertidumbre se trata con técnicas de machine learning. Al utilizar estas técnicas se espera aprender el comportamiento de la fuga y su incertidumbre asociada para tenerlo en cuenta en la fase de diagnóstico. El método presentado para la detección de fugas tiene la habilidad de estimar la magnitud y el instante en que la fuga se ha producido. Este método captura el comportamiento normal, sin fugas, del sistema y lo contrasta con las nuevas medidas para evaluar el estado actual de la red. En el caso de que el comportamiento no sea el normal, se comprueba si es debido a la presencia de una fuga en el sistema. Para obtener un método de detección más robusto, se considera una capa de validación especialmente diseñada para trabajar específicamente con fugas y durante el periodo temporal donde la fuga es más evidente. Esta técnica se compara con otras ya publicadas proporcionando una detección más fiable, especialmente en el caso de fugas pequeñas, al mismo tiempo que proporciona más información que puede ser usada en la fase de la localización de la fuga permitiendo mejorarla. El principal problema es que el método es más lento que los otros métodos analizados. Con el fin de mejorar la actual metodología de localización de fugas mediante modelos hidráulicos, se propone la utilización de clasificadores. Concretamente, se propone el clasificador no paramétrico k-nearest neighbors y el clasificador Bayesiano paramétrico para múltiples clases. La propuesta de localización de fugas mediante modelos hidráulicos y clasificadores permite gestionar la incertidumbre de los datos mejor para obtener un diagnóstico de la localización de la fuga más preciso. El principal inconveniente recae en el coste computacional, aunque no se realiza en tiempo real, de los datos necesarios por el clasificador para aprender correctamente la dispersión de los datos. Además, el método es muy dependiente de la calidad del modelo hidráulico de la red. En el campo de la localización de fugas, se a propuesto un nuevo método de localización de fugas basado en modelos de datos mediante la regresión de múltiples parámetros sin el uso de modelo hidráulico. Este método presenta un claro beneficio respecto a las técnicas basadas en modelos hidráulicos ya que prescinde de su uso, aunque la información topológica de la red es aún necesaria. Además, la información del comportamiento de la red para cada fuga no es necesario, ya que el conocimiento del efecto hidráulico de una fuga en un determinado punto de la red es utilizado para la localización. Este método ha dado muy buenos resultados en la práctica, aunque es muy sensible al número de sensores y a su colocación en la red. Finalmente, se trata el problema de la colocación de sensores. El desempeño de la localización de fugas está ligado a la colocación de los sensores y es particular para cada método. Con el objetivo de maximizar el desempeño de los métodos de localización de fugas presentados, técnicas de colocación de sensores específicamente diseñados para ellos se han presentado y evaluado. Dado que el problema de combinatoria que presenta no puede ser tratado analizando todas las posibles combinaciones de sensores excepto en las redes más pequeñas con unos pocos sensores para instalar. Estas técnicas de colocación de sensores explotan el potencial de las técnicas de selección de variables para realizar la tarea deseada. Las técnicas de colocación de sensores propuestas reducen la carga computacional, requerida para tener en cuenta todos los datos necesarios para modelar bien la incertidumbre, comparado con otras propuestas de optimización al mismo tiempo que están diseñadas para trabajar en la tarea de la localización de fugas. Más concretamente, la propuesta basada en la técnica híbrida de selección de variables para la colocación de sensores es capaz de trabajar con cualquier técnica de localización de fugas que se pueda evaluar con la matriz de confusión y ser a la vez óptimo. Este método es muy bueno para la colocación de sensores, pero el rendimiento disminuye a medida que el número de sensores a colocar crece. Para evitar este problema, se propone método de colocación de sensores de forma incremental que presenta un mejor rendimiento para un número alto de sensores a colocar, aunque no es tan eficaz con pocos sensores a colocar.Postprint (published version

    Probabilistic localization of gas emission areas with a mobile robot in indoor environments

    Get PDF
    This work deals with the problem of gas source localization by a mobile robot with gas-sensing capabilities. Particularly, we address the problem for the case of indoor environments, where the presence of obstacles and the possibly complex structure with multiple rooms, inlets and outlets provoke the chaotic dispersion of the gases. Under these challenging conditions, where traditional approaches based on tracking or mathematical modeling of the plume cannot be applied, we propose a two-stage methodology to split the search into coarse and fine localization. Focusing on the broad localization, we contribute with a novel approach to estimate, from a set of sparse observations, the likelihood of different regions in the environment to hold a gas source. Experiments demonstrate that our approach is suitable to locate gas emission sources.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech

    Multiple Surface Pipeline Leak Detection Using Real-Time Sensor Data Analysis

    Get PDF
    Pipelines enable the largest volume of both intra and international transportation of oil and gas and play critical roles in the energy sufficiency of countries. The biggest drawback with the use of pipelines for oil and gas transportation is the problem of oil spills whenever the pipelines lose containment. The severity of the oil spill on the environment is a function of the volume of the spill and this is a function of the time taken to detect the leak and contain the spill from the pipeline. A single leak on the Enbridge pipeline spilled 3.3 million liters into the Kalamazoo river while a pipeline rupture in North Dakota which went undetected for 143 days spilled 29 million gallons into the environment.Several leak detection systems (LDS) have been developed with the capacity for rapid detection and localization of pipeline leaks, but the characteristics of these LDS limit their leak detection capability. Machine learning provides an opportunity to develop faster LDS, but it requires access to pipeline leak datasets that are proprietary in nature and not readily available. Current LDS have difficulty in detecting low-volume/low-pressure spills located far away from the inlet and outlet pressure sensors. Some reasons for this include the following, leak induced pressure variation generated by these leaks is dissipated before it gets to the inlet and outlet pressure sensors, another reason is that the LDS are designed for specific minimum detection levels which is a percentage of the flow volume of the pipeline, so when the leak falls below the LDS minimum detection value, the leak will not be detected. Perturbations generated by small volume leaks are often within the threshold values of the pipeline\u27s normal operational envelop as such the LDS disregards these perturbations. These challenges have been responsible for pipeline leaks going on for weeks only to be detected by third-party persons in the vicinity of the leaks. This research has been able to develop a framework for the generation of pipeline datasets using the PIPESIM software and the RAND function in Python. The topological data of the pipeline right of way, the pipeline network design specification, and the fluid flow properties are the required information for this framework. With this information, leaks can be simulated at any point on the pipeline and the datasets generated. This framework will facilitate the generation of the One-class dataset for the pipeline which can be used for the development of LDS using machine learning. The research also developed a leak detection topology for detecting low-volume leaks. This topology comprises of the installation of a pressure sensor with remote data transmission capacity at the midpoint of the line. The sensor utilizes the exception-based transmission scheme where it only transmits when the new data differs from the existing data value. This will extend the battery life of the sensor. The installation of the sensor at the midpoint of the line was found to increase the sensitivity of the LDS to leak-induced pressure variations which were traditionally dissipated before getting to the Inlet/outlet sensors. The research also proposed the development of a Leak Detection as a Service (LDaaS) platform where the pressure data from the inlet and the midpoint sensors are collated and subjected to a specially developed leak detection algorithm for the detection of pipeline leaks. This leak detection topology will enable operators to detect low-volume/low-pressure leaks that would have been missed by the existing leak detection system and deploy the oil spill response plans quicker thus reducing the volume of oil spilled into the environment. It will also provide a platform for regulators to monitor the leak alerts as they are generated and enable them to evaluate the oil spill response plans of the operators

    Leak Detection and Localization in Pressurized Space Structures Using Bayesian Inference: Theory and Practice

    Get PDF
    Impact from micrometeoroids and orbital debris (MMOD) can cause severe damage to space vehicles. The crew habitat can begin to leak precious oxygen, critical systems can be punctured causing fatal failures, and an accumulation of impacts by MMOD can decrease the lifetime of any and all devices in space. Due to these and other potential dangers, MMODs have been considered the third largest threat to spacecraft after launch and re-entry. Many satellites and other spacecraft face this very problem inherent in all space travel on a daily basis, but often times they can be repaired. A major hurdle is to first be able to identify the presence of a leak. Many times an impact and subsequent leak is not discovered until it has caused a problem. A complete system is needed to detect and localize the impact to improve longevity of the habitat or other pressurized space structures. In this work, a system for detection and localization of air leaks using air-borne acoustic waves is proposed. The system uses microelectromechanical systems (MEMS) microphone sensors to detect and record high frequency noise in an environment, angle of arrival (AOA) calculations to estimate possible leak locations, and a Bayesian tree-search filter to detect and more accurately localize a leak. This work includes proof of concept, simulations, and physical prototypes as steps to creation of a complete system. Data from deployed flight test using said prototypes are analyzed. Modeling the effects of environmental reflections on the accuracy of localization is also studied

    Autonomous search for a diffusive source in an unknown environment

    Full text link
    The paper presents an approach to olfactory search for a diffusive emitting source of tracer (e.g. aerosol, gas) in an environment with unknown map of randomly placed and shaped obstacles. The measurements of tracer concentration are sporadic, noisy and without directional information. The search domain is discretised and modelled by a finite two-dimensional lattice. The links is the lattice represent the traversable paths for emitted particles and for the searcher. A missing link in the lattice indicates a blocked paths, due to the walls or obstacles. The searcher must simultaneously estimate the source parameters, the map of the search domain and its own location within the map. The solution is formulated in the sequential Bayesian framework and implemented as a Rao-Blackwellised particle filter with information-driven motion control. The numerical results demonstrate the concept and its performance.Comment: 11 pages, 7 figure

    Sensor placement for classifier-based leak localization in water distribution networks using hybrid feature selection

    Get PDF
    This paper presents a sensor placement approach for classifier-based leak localization in water distribution networks. The proposed method is based on a hybrid feature selection algorithm that combines the use of a filter based on relevancy and redundancy with a wrapper based on genetic algorithms. This algorithm is applied to data generated by hydraulic simulation of the considered water distribution network and it determines the optimal location of a prespecified number of pressure sensors to be used by a leak localization method based on pressure models and classifiers proposed in previous works by the authors. The method is applied to a small-size simplified network (Hanoi) to better analyze its computational performance and to a medium-size network (Limassol) to demonstrate its applicability to larger real-size networks.Peer ReviewedPostprint (author's final draft
    • …
    corecore