310 research outputs found
Individualized and generalized earphone correction filters for spatil sound reproduction
Proceedings of the 9th International Conference on Auditory Display (ICAD), Boston, MA, July 7-9, 2003.Earphone-based simulation ofHead-Related Transfer Functions (HRTFs) is a common component of spatial auditory display for virtual sound sources located in virtual environments, but one technical component of HRTF deployment that requires special care has not always received proper attention. The audio signals to be presented to the listener are not often properly corrected for the response of earphones, and yet such correction has long been regarded as crucial to the success of spatial sound reproduction using earphones. Two approaches to developing Earphone Correction Filters (ECFs) are contrasted in this paper, one based on the assumption that the ECF must be based upon an inversion the user's individually measured Earphone Transfer Functions, and the other based upon the assumption that a satisfactory result can be attained through a general equalization for correcting the tone coloration imparted by the averaged ETF. The results of these two approaches were perceptually evaluated for a range of stimuli generated by varying the shape of an experimental ECF using a fouralternative, forced-choice (4AFC) test. Changes in auditory imagery associated with speech stimuli were easily detected and discriminated when comparing reproductions with and without earphone correction, but perceptual differences were much more difficult to detect as the shape of the experimental ECF was varied by frequency scaling. Further forced-choice tests showed that ECF frequency scaling factors of 0.8 and 1.2 do not result in detectable differences, but factors of 0.6 or 1.4 make detectable differences
Perceived Self Motion in Virtual Acoustic Space Facilitated by Passive Whole-Body Movement
Presented at the 14th International Conference on Auditory Display (ICAD2008) on June 24-27, 2008 in Paris, France.When moving sound sources are displayed for a listener in a manner that is consistent with the motion of a listener through an environment populated by stationary sound sources, listeners may perceive that the sources are moving relative to a fixed listening position, rather than experiencing their own self motion (i.e., a change in their listening position). Here, the likelihood of auditory cues producing such self motion (aka auditory-induced vection) can be greatly facilitated by coordinated passive movement of a listener's whole body, which can be achieved when listeners are positioned upon a multi-axis motion platform that is controlled in synchrony with a spatial auditory display. In this study, the temporal synchrony between passive whole-body motion and auditory spatial information was investigated via a multimodal time-order judgment task. For the spatial trajectories taken by sound sources presented here, the observed interaction between passive whole-body motion and sound source motion clearly depended upon the peak velocity reached by the moving sound sources. The results suggest that sensory integration of auditory motion cues with whole-body movement cues can occur over an increasing range of intermodal delays as virtual sound sources are moved increasingly slowly through the space near a listener's position. Furthermore, for the coordinated motion presented in the current study, asynchrony was relatively easy for listeners to tolerate when the peak in whole-body motion occurred earlier in time than the peak in virtual sound source velocity, but quickly grew to be intolerable when the peak in whole-body motion occurred after sound sources reached their peak velocities
From Heisenberg matrix mechanics to EBK quantization: theory and first applications
Despite the seminal connection between classical multiply-periodic motion and
Heisenberg matrix mechanics and the massive amount of work done on the
associated problem of semiclassical (EBK) quantization of bound states, we show
that there are, nevertheless, a number of previously unexploited aspects of
this relationship that bear on the quantum-classical correspondence. In
particular, we emphasize a quantum variational principle that implies the
classical variational principle for invariant tori. We also expose the more
indirect connection between commutation relations and quantization of action
variables. With the help of several standard models with one or two degrees of
freedom, we then illustrate how the methods of Heisenberg matrix mechanics
described in this paper may be used to obtain quantum solutions with a modest
increase in effort compared to semiclassical calculations. We also describe and
apply a method for obtaining leading quantum corrections to EBK results.
Finally, we suggest several new or modified applications of EBK quantization.Comment: 37 pages including 3 poscript figures, submitted to Phys. Rev.
Measurement of Angular Distributions and R= sigma_L/sigma_T in Diffractive Electroproduction of rho^0 Mesons
Production and decay angular distributions were extracted from measurements
of exclusive electroproduction of the rho^0(770) meson over a range in the
virtual photon negative four-momentum squared 0.5< Q^2 <4 GeV^2 and the
photon-nucleon invariant mass range 3.8< W <6.5 GeV. The experiment was
performed with the HERMES spectrometer, using a longitudinally polarized
positron beam and a ^3He gas target internal to the HERA e^{+-} storage ring.
The event sample combines rho^0 mesons produced incoherently off individual
nucleons and coherently off the nucleus as a whole. The distributions in one
production angle and two angles describing the rho^0 -> pi+ pi- decay yielded
measurements of eight elements of the spin-density matrix, including one that
had not been measured before. The results are consistent with the dominance of
helicity-conserving amplitudes and natural parity exchange. The improved
precision achieved at 47 GeV,
reveals evidence for an energy dependence in the ratio R of the longitudinal to
transverse cross sections at constant Q^2.Comment: 15 pages, 15 embedded figures, LaTeX for SVJour(epj) document class
Revision: Fig. 15 corrected, recent data added to Figs. 10,12,14,15; minor
changes to tex
The state of the Martian climate
60°N was +2.0°C, relative to the 1981–2010 average value (Fig. 5.1). This marks a new high for the record. The average annual surface air temperature (SAT) anomaly for 2016 for land stations north of starting in 1900, and is a significant increase over the previous highest value of +1.2°C, which was observed in 2007, 2011, and 2015. Average global annual temperatures also showed record values in 2015 and 2016. Currently, the Arctic is warming at more than twice the rate of lower latitudes
Determination of the Deep Inelastic Contribution to the Generalised Gerasimov-Drell-Hearn Integral for the Proton and Neutron
The virtual photon absorption cross section differences [sigma_1/2-sigma_3/2]
for the proton and neutron have been determined from measurements of polarised
cross section asymmetries in deep inelastic scattering of 27.5 GeV
longitudinally polarised positrons from polarised 1H and 3He internal gas
targets. The data were collected in the region above the nucleon resonances in
the kinematic range nu < 23.5 GeV and 0.8 GeV**2 < Q**2 < 12 GeV**2. For the
proton the contribution to the generalised Gerasimov-Drell-Hearn integral was
found to be substantial and must be included for an accurate determination of
the full integral. Furthermore the data are consistent with a QCD
next-to-leading order fit based on previous deep inelastic scattering data.
Therefore higher twist effects do not appear significant.Comment: 6 pages, 3 figures, 1 table, revte
Method for Quantitative Study of Airway Functional Microanatomy Using Micro-Optical Coherence Tomography
We demonstrate the use of a high resolution form of optical coherence tomography, termed micro-OCT (μOCT), for investigating the functional microanatomy of airway epithelia. μOCT captures several key parameters governing the function of the airway surface (airway surface liquid depth, periciliary liquid depth, ciliary function including beat frequency, and mucociliary transport rate) from the same series of images and without exogenous particles or labels, enabling non-invasive study of dynamic phenomena. Additionally, the high resolution of μOCT reveals distinguishable phases of the ciliary stroke pattern and glandular extrusion. Images and functional measurements from primary human bronchial epithelial cell cultures and excised tissue are presented and compared with measurements using existing gold standard methods. Active secretion from mucus glands in tissue, a key parameter of epithelial function, was also observed and quantified
The direct effect of Focal Adhesion Kinase (FAK), dominant-negative FAK, FAK-CD and FAK siRNA on gene expression and human MCF-7 breast cancer cell tumorigenesis
<p>Abstract</p> <p>Background</p> <p>Focal adhesion kinase (FAK) is a non-receptor tyrosine kinase that plays an important role in survival signaling. FAK has been shown to be overexpressed in breast cancer tumors at early stages of tumorigenesis.</p> <p>Methods</p> <p>To study the direct effect of FAK on breast tumorigenesis, we developed Tet-ON (tetracycline-inducible) system of MCF-7 breast cancer cells stably transfected with FAK or dominant-negative, C-terminal domain of FAK (FAK-CD), and also FAKsiRNA with silenced FAK MCF-7 stable cell line. Increased expression of FAK in isogenic Tet-inducible MCF-7 cells caused increased cell growth, adhesion and soft agar colony formation <it>in vitro</it>, while expression of dominant-negative FAK inhibitor caused inhibition of these cellular processes. To study the role of induced FAK and FAK-CD <it>in vivo</it>, we inoculated these Tet-inducible cells in nude mice to generate tumors in the presence or absence of doxycycline in the drinking water. FAKsiRNA-MCF-7 cells were also injected into nude mice to generate xenograft tumors.</p> <p>Results</p> <p>Induction of FAK resulted in significant increased tumorigenesis, while induced FAK-CD resulted in decreased tumorigenesis. Taq Man Low Density Array assay demonstrated specific induction of FAKmRNA in MCF-7-Tet-ON-FAK cells. DMP1, encoding cyclin D binding myb-like protein 1 was one of the genes specifically affected by Tet-inducible FAK or FAK-CD in breast xenograft tumors. In addition, silencing of FAK in MCF-7 cells with FAK siRNA caused increased cell rounding, decreased cell viability <it>in vitro </it>and inhibited tumorigenesis <it>in vivo</it>. Importantly, Affymetrix microarray gene profiling analysis using Human Genome U133A GeneChips revealed >4300 genes, known to be involved in apoptosis, cell cycle, and adhesion that were significantly down- or up-regulated (p < 0.05) by FAKsiRNA.</p> <p>Conclusion</p> <p>Thus, these data for the first time demonstrate the direct effect of FAK expression and function on MCF-7 breast cancer tumorigenesis <it>in vivo </it>and reveal specific expression of genes affected by silencing of FAK.</p
Transcriptome Profiling of Whole Blood Cells Identifies PLEK2 and C1QB in Human Melanoma
Developing analytical methodologies to identify biomarkers in easily accessible body fluids is highly valuable for the early diagnosis and management of cancer patients. Peripheral whole blood is a "nucleic acid-rich" and "inflammatory cell-rich" information reservoir and represents systemic processes altered by the presence of cancer cells.We conducted transcriptome profiling of whole blood cells from melanoma patients. To overcome challenges associated with blood-based transcriptome analysis, we used a PAXgene™ tube and NuGEN Ovation™ globin reduction system. The combined use of these systems in microarray resulted in the identification of 78 unique genes differentially expressed in the blood of melanoma patients. Of these, 68 genes were further analyzed by quantitative reverse transcriptase PCR using blood samples from 45 newly diagnosed melanoma patients (stage I to IV) and 50 healthy control individuals. Thirty-nine genes were verified to be differentially expressed in blood samples from melanoma patients. A stepwise logit analysis selected eighteen 2-gene signatures that distinguish melanoma from healthy controls. Of these, a 2-gene signature consisting of PLEK2 and C1QB led to the best result that correctly classified 93.3% melanoma patients and 90% healthy controls. Both genes were upregulated in blood samples of melanoma patients from all stages. Further analysis using blood fractionation showed that CD45(-) and CD45(+) populations were responsible for the altered expression levels of PLEK2 and C1QB, respectively.The current study provides the first analysis of whole blood-based transcriptome biomarkers for malignant melanoma. The expression of PLEK2, the strongest gene to classify melanoma patients, in CD45(-) subsets illustrates the importance of analyzing whole blood cells for biomarker studies. The study suggests that transcriptome profiling of blood cells could be used for both early detection of melanoma and monitoring of patients for residual disease
- …