36 research outputs found

    Effect of the Estrus Expression on Follicular and Luteal Morphofunctional Characteristics and Fertility in Bos indicus females Synchronized for FTAI

    Get PDF
    Background: Recent studies have been conducted with the aim of improving the fertility rates in the FTAI programs in beef females. The observation of the estrus expression constitutes an important indicator of fertility in zebu females. Therefore, this work has as an objective to evaluate the impact of the estrus expression on the follicular, luteal and fertility morphofunctional characteristics of Nelore females synchronized for FTAI.Materials, Methods & Results: Sixty five lactating female Nelore (Bos taurus indicus) were used. On a random day, denominated day 0 (D0), the 65 Nelore females received a progesterone-releasing device associated to the application of 2.0 mg of estradiol benzoate intramuscularly (IM). On D9, the progesterone-releasing intravaginal devices were removed and was administered 500 μg of cloprostenol sodium IM; 0.6 mg of estradiol cypionate IM and 300 UI of Equine Chorionic Gonadotropin IM. At this point, the animals were marked with a marking stick for the determination of the estrus expression. On D11 of the synchronization protocol, the animals were characterized in two groups: without estrus expression (WO/ ESTRUS) and with estrus expression (W/ ESTRUS). The evaluation of the follicle diameter (FOLD), of the follicle wall area (FOLA), of the follicle wall vascularization (FOLV) and the percentage of vascularization in the area of the preovulatory follicle wall (%FOLV) were conducted on D11 using B-mode ultrasonography and color Doppler and then the artificial inseminations were performed. The evaluation of the corpus luteum diameter (CLD), the total area of the corpus luteum (CLA), of the area of vascularization of the corpus luteum (CLV), of the percentage of vascularization of the in the area of the corpus luteum (% CLV) and the collection of blood for the evaluation of the serum levels of progesterone were carried out on D24. The analysis of the serum progesterone concentration were performed by the chemiluminescence method using the Access immunoassay systems Progesterone, with a sensitivity of 0.1 ng/mL. The diagnosis of gestation was carried out by transrectal ultrasonography on D45.  The animals of the WITH ESTRUS group presented superior FOLD, FOLA, FOV (P < 0.05) averages to those presented by the cows of the WITHOUT ESTRUS group. In relation to the luteal characteristics, in the WITH ESTRUS group the cows exhibited averages for CLD, CLA, CLV and P4 significantly higher than those of the WITHOUT ESTRUS group. However, the bovines of the WITH ESTRUS group presented a % CLV similar to the presented by the females of the WITHOUT ESTRUS group. As for the fertility rates, there was difference between the experimental groups WITH ESTRUS and WITHOUT ESTRUS.Discussion: The present work demonstrated the impact of the estrus expression on the follicular morphological parameters, therefore in accordance with other studies. These authors show a relation between the estrus expression and levels of estradiol, which is directly related to the sperm transport in the female reproductive tract, oocyte maturation and fertilization directly affecting the fertility of females submitted to the FTAI program. Similarly, there was an interrelation between the estrus expression and the luteal morphological parameters, corroborating with the findings of some researches, where were verified higher luteal morphological parameters associated to higher conception rates in cows that demonstrated estrus behavior in the FTAI. Therefore, the estrus detection can be used as a tool to direct matings in synchronization protocols, promoting the identification of the animals with a higher probability of conception, owing to better follicular and luteal hemodynamic conditions

    Temporada de Minicursos: a capacitação como meio efetivo de desenvolvimento técnico e interpessoal de universitários

    Get PDF
    The enlargement of the development of skills and competences in university students becomes of great importance for insertion in the labor market, since, in general, the gap between academic education and the labor market is evident. Therefore, this article aims to analyze the importance of extracurricular training, focusing on the Temporada de Minicursos (TMC), an activity developed by the Tutorial Education Program (PET) of the Civil Engineering course at the Federal University of Ceará (UFC), in the development of hard skills and soft skills of the participants. To achieve the objectives, two analyzes were performed, one quantitative and the other qualitative, based on data obtained from the 8th edition of TMC. The results obtained on the analyzes showed that the participants involved in the activity were able to develop their skills and, consequently, apply them in the academic and professional areas.A ampliação do desenvolvimento de habilidades e competências dos estudantes universitários torna-se de grande importância para a inserção no mercado de trabalho, uma vez que, de maneira geral, é evidente o descompasso da formação acadêmica e o mercado de trabalho. Em vista disso, o presente artigo objetiva analisar a importância das capacitações extracurriculares, com foco na atividade Temporada de Minicursos (TMC) desenvolvida pelo Programa de Educação Tutorial (PET) do curso de Engenharia Civil da Universidade Federal do Ceará (UFC), no desenvolvimento de hard skills e soft skills dos participantes. Para alcançar os objetivos, realizaram-se duas análises, uma quantitativa e outra qualitativa, com base em dados obtidos a partir da 8ª edição da TMC. Os resultados obtidos nas análises mostraram que os participantes envolvidos na atividade foram capazes de desenvolver suas habilidades e, consequentemente, aplicá-las em âmbitos acadêmicos e profissionais

    Recrutas da Alegria: promoção da saúde no Hospital Universitário da Universidade Federal do Rio Grande

    Get PDF
    Anais do 35º Seminário de Extensão Universitária da Região Sul - Área temática: SaúdeO Recrutas da Alegria foi idealizado a partir do olhar dos acadêmicos da área da saúde no ambiente hospitalar, com a intenção de melhorar esse ambiente e desenvolver uma prática mais humanizada. Inúmeras vezes o tecnicismo e o biologicismo dos cursos da saúde tornam seus profissionais muito centrados nos aspectos fisiopatológicos, ficando em segundo plano o atendimento centrado no paciente. Nos últimos anos o palhaço tem gradualmente participado dos espaços hospitalares, com o intuito de promover um espaço de “terapia da alegria”. O programa Recrutas da Alegria desenvolve-se baseado em uma metodologia interdisciplinar, integrando diversas áreas do conhecimento, com a participação dos cursos de medicina, enfermagem, psicologia e fisioterapia estabelecendo ações de ação- reflexão-ação, utilizando-se da figura do clown como promotor destas práticas. O Recrutas da Alegria possibilita aos acadêmicos, através do lúdico, uma melhor percepção da realidade dos pacientes, resultando na conscientização da importância de um olhar mais integral com relação aos pacientes na prática de sua futura profissã

    Possible oxidative effects of isotretinoin and modulatory effects of vitamins A and C in Saccharomyces cerevisiae

    Get PDF
    Isotretinoin (ITN), chemically known as 13-cis-retinoic acid, is a part of the broad group of compounds related to vitamin A. It is particularly employed in the treatment of nodular cystic acne and as an inhibitor of proliferation of neoplastic cells, by exerting a regulatory effect on the cell differentiation. This study aimed at investigating the possible oxidative effects of ITN and modulatory effects of vitamins A and C in mutant and non-mutant Saccharomyces cerevisiae strains. In addition, to reconfirm the oxidative effects, five in vitro antioxidant assays were also prepared taking the alpha-tocopherol analogue, trolox as a standard. In vivo study conducted on S. cerevisiae cells was carried out with ITN 20 μg/ml taking hydrogen peroxide (H2O2) as stressor (STR), whereas ITN 5 to 50 μg/ml was considered for in vitro assays taking similar dose of trolox (TRO). Results show ITN to have oxidative effect in both in vitro and in vivo tests. In conclusion, ITN produced oxidative effects and there may be an hypervitaminosis effect with vitamins A and C, thus insinuation to genetic material.Key words: Assay, isotretinoin, vitamin A, vitamin C, oxidative stress

    Consenso brasileiro para o tratamento da esclerose múltipla : Academia Brasileira de Neurologia e Comitê Brasileiro de Tratamento e Pesquisa em Esclerose Múltipla

    Get PDF
    O crescent arsenal terapêutico na esclerose múltipla (EM) tem permitido tratamentos mais efetivos e personalizados, mas a escolha e o manejo das terapias modificadoras da doença (TMDs) tem se tornado cada vez mais complexos. Neste contexto, especialistas do Comitê Brasileiro de Tratamento e Pesquisa em Esclerose Múltipla e do Departamento Científico de Neuroimunologia da Academia Brasileira de Neurologia reuniram-se para estabelecer este Consenso Brasileiro para o Tratamento da EM, baseados no entendimento de que neurologistas devem ter a possibilidade de prescrever TMDs para EM de acordo com o que é melhor para cada paciente, com base em evidências e práticas atualizadas. Por meio deste documento, propomos recomendações práticas para o tratamento da EM, com foco principal na escolha e no manejo das TMDs, e revisamos os argumentos que embasam as estratégias de tratamento na EM.The expanding therapeutic arsenal in multiple sclerosis (MS) has allowed for more effective and personalized treatment, but the choice and management of disease-modifying therapies (DMTs) is becoming increasingly complex. In this context, experts from the Brazilian Committee on Treatment and Research in Multiple Sclerosis and the Neuroimmunology Scientific Department of the Brazilian Academy of Neurology have convened to establish this Brazilian Consensus for the Treatment of MS, based on their understanding that neurologists should be able to prescribe MS DMTs according to what is better for each patient, based on up-to-date evidence and practice. We herein propose practical recommendations for the treatment of MS, with the main focus on the choice and management of DMTs, as well as present a review of the scientific rationale supporting therapeutic strategies in MS

    Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023

    Get PDF
    Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population. Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care. It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations. Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced. Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM). Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance. Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial. La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización. Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones. Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA. La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA). Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia. Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial. A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização. Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações. Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA. A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA). Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz). Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento

    Algoritmos exatos para a manipulação de mapas na TerraLib

    No full text
    O objetivo deste trabalho é abordar algoritmos exatos (livre de erros de arredondamento) para a manipulação geométrica de dados geográficos. O principal foco deste artigo é o algoritmo de sobreposição de mapas, tendo como ambiente de desenvolvimento a TerraLib, uma biblioteca de componentes espaciais com suporte a algoritmos geométricos.Pages: 245-25

    Análise da eficiência na produção de energia eólica nos principais estados brasileiros produtores, por meio da aplicação de análise por envoltória de dados

    Get PDF
    A energia eólica é uma energia produzida pela força dos ventos, sendo considerada limpa e renovável. Múltiplos são os fatores que podem ser utilizados para analisar a eficiência na produção de eletricidade a partir dos ventos. O objetivo principal deste artigo de pesquisa consiste em avaliar a eficiência relativa da geração eólica nos principais estados brasileiros produtores, durante o ano de 2014, por meio de análise por envoltória de dados. Das onze unidades avaliadas, quatro foram consideradas eficientes e sete, não eficientes. Em seguida, o modelo da fronteira invertida foi usado de modo a ordenar as unidades. Além disso, o método da fronteira invertida identificou duas unidades eficientes apresentando uma falsa eficiência. Assim, a produção de energia eólica do Estado do Piauí se apresentou como a unidade mais eficiente de todo o conjunto analisado, em contraste com o Estado de Pernambuco, que foi considerado como o menos eficiente de todos

    Uma Investigação Quasi-Experimental sobre a Adoção e o Uso da Notação BPMN

    No full text
    This article aimed to investigate whether adopting and using the Business Process Model and Notation (BPMN) are perceived differently from the introduction of simplified versions of its symbols, adapted to the context of training process leaders in an organization. For this, a quasi-experiment was used involving 41 employees in the supply area of a company in the Brazilian electricity sector, participating in training for process leaders. The individuals undertook two rounds of task execution, where at the end of each one, they answered the research questionnaire. The UTAUT model was used as theoretical support, presenting its variables and constructs in the data collection instrument. The main result points out that the manipulation of the BPMN notation resulted in statistically significant differences for 13 of the 15 dependent variables measured between the experimental groups and the control group, meeting the initial objective of the study. Based on this, hypotheses and an agenda for future studies are suggested.Este artículo tuvo como objetivo averiguar si la adopción y uso de la Business Process Model and Notation (BPMN) son percibidos de manera distinta a partir de la introducción de versiones simplificadas de sus signos, adaptadas a un contexto de formación de líderes de procesos en una organización. Para eso, se utilizó un casi-experimento envolviendo 41 trabajadores del área de suministro de una empresa del sector eléctrico brasileño, participantes de un entrenamiento para líderes de procesos. Los individuos emprendieron dos jornadas de ejecución de tareas, dónde al término de cada una de ellas contestaron al cuestionario de la investigación. Como aporte teórico se echó mano del modelo UTAUT, presentando sus variables y constructos en el instrumento de colecta de datos. El principal resultado indica que la manipulación de la notación BPMN terminó en diferencias estadísticamente significativas para 13 de las 15 variables dependientes mensuradas entre los grupos experimentales y el grupo de control, atendiendo al objetivo inicial del estudio. A partir de esto son sugeridas hipótesis y una agenda de futuros estudios.Este artigo teve como objetivo averiguar se a adoção e uso da Business Process Model and Notation (BPMN) são percebidos de maneira distinta a partir da introdução de versões simplificadas de seus símbolos, adaptadas a um contexto de formação de líderes de processos em uma organização. Para isso, fez-se uso de um quasi-experimento envolvendo 41 empregados da área de suprimento de uma empresa do setor elétrico brasileiro, participantes de um treinamento para líderes de processos. Os indivíduos empreenderam duas rodadas de execução de tarefas, onde ao término de cada uma delas responderam ao questionário da pesquisa. Como suporte teórico lançou-se mão do modelo UTAUT, apresentando suas variáveis e constructos no instrumento de coleta de dados. O principal resultado aponta que a manipulação da notação BPMN findou em diferenças estatisticamente significativas para 13 das 15 variáveis dependentes mensuradas entre os grupos experimentais e o grupo controle, atendendo ao objetivo inicial do estudo. A partir disso são sugeridas hipóteses e uma agenda de estudos futuros
    corecore