373 research outputs found
Moderate drinking before the unit: medicine and life assurance in Britain and the US c.1860–1930
This article describes the way in which “Anstie’s Limit” – a particular definition of moderate drinking first defined in Britain in the 1860s by the physician Francis Edmund Anstie (1833–1874) – became established as a useful measure of moderate alcohol consumption. Becoming fairly well-established in mainstream Anglophone medicine by 1900, it was also communicated to the public in Britain, North America and New Zealand through newspaper reports. However, the limit also travelled to less familiar places, including life assurance offices, where a number of different strategies for separating moderate from excessive drinkers emerged from the dialogue between medicine and life assurance. Whilst these ideas of moderation seem to have disappeared into the background for much of the twentieth century, re-emerging as the “J-shaped” curve, these early developments anticipate many of the questions surrounding uses of the “unit” to quantify moderate alcohol consumption in Britain today. The article will therefore conclude by exploring some of the lessons of this story for contemporary discussions of moderation, suggesting that we should pay more attention to whether these metrics work, where they work and why
Search for composite and exotic fermions at LEP 2
A search for unstable heavy fermions with the DELPHI detector at LEP is
reported. Sequential and non-canonical leptons, as well as excited leptons and
quarks, are considered. The data analysed correspond to an integrated
luminosity of about 48 pb^{-1} at an e^+e^- centre-of-mass energy of 183 GeV
and about 20 pb^{-1} equally shared between the centre-of-mass energies of 172
GeV and 161 GeV. The search for pair-produced new leptons establishes 95%
confidence level mass limits in the region between 70 GeV/c^2 and 90 GeV/c^2,
depending on the channel. The search for singly produced excited leptons and
quarks establishes upper limits on the ratio of the coupling of the excited
fermio
Study of Tau-pair Production in Photon-Photon Collisions at LEP and Limits on the Anomalous Electromagnetic Moments of the Tau Lepton
Tau-pair production in the process e+e- -> e+e-tau+tau- was studied using
data collected by the DELPHI experiment at LEP2 during the years 1997 - 2000.
The corresponding integrated luminosity is 650 pb^{-1}. The values of the
cross-section obtained are found to be in agreement with QED predictions.
Limits on the anomalous magnetic and electric dipole moments of the tau lepton
are deduced.Comment: 20 pages, 9 figures, Accepted by Eur. Phys. J.
Evidence for an Excess of Soft Photons in Hadronic Decays of Z^0
Soft photons inside hadronic jets converted in front of the DELPHI main
tracker (TPC) in events of qqbar disintegrations of the Z^0 were studied in the
kinematic range 0.2 < E_gamma < 1 GeV and transverse momentum with respect to
the closest jet direction p_T < 80 MeV/c. A clear excess of photons in the
experimental data as compared to the Monte Carlo predictions is observed. This
excess (uncorrected for the photon detection efficiency) is (1.17 +/- 0.06 +/-
0.27) x 10^{-3} gamma/jet in the specified kinematic region, while the expected
level of the inner hadronic bremsstrahlung (which is not included in the Monte
Carlo) is (0.340 +/- 0.001 +/- 0.038) x 10^{-3} gamma/jet. The ratio of the
excess to the predicted bremsstrahlung rate is then (3.4 +/- 0.2 +/- 0.8),
which is similar in strength to the anomalous soft photon signal observed in
fixed target experiments with hadronic beams.Comment: 37 pages, 9 figures, Accepted by Eur. Phys. J.
Energy dependence of Cronin momentum in saturation model for and collisions
We calculate dependence of Cronin momentum for and
collisions in saturation model. We show that this dependence is consistent with
expectation from formula which was obtained using simple dimentional
consideration. This can be used to test validity of saturation model (and
distinguish among its variants) and measure dependence of saturation
momentum from experimental data.Comment: LaTeX2e, 12 pages, 8 figure
Study of Inclusive J/psi Production in Two-Photon Collisions at LEP II with the DELPHI Detector
Inclusive J/psi production in photon-photon collisions has been observed at
LEP II beam energies. A clear signal from the reaction gamma gamma -> J/psi+X
is seen. The number of observed N(J/psi -> mu+mu-) events is 36 +/- 7 for an
integrated luminosity of 617 pb^{-1}, yielding a cross-section of
sigma(J/psi+X) = 45 +/- 9 (stat) +/- 17 (syst) pb. Based on a study of the
event shapes of different types of gamma gamma processes in the PYTHIA program,
we conclude that (74 +/- 22)% of the observed J/psi events are due to
`resolved' photons, the dominant contribution of which is most probably due to
the gluon content of the photon.Comment: 13 pages, 8 figures, Accepted by Phys. Lett.
CP asymmetry in in a general two-Higgs-doublet model with fourth-generation quarks
We discuss the time-dependent CP asymmetry of decay in an
extension of the Standard Model with both two Higgs doublets and additional
fourth-generation quarks. We show that although the Standard Model with
two-Higgs-doublet and the Standard model with fourth generation quarks alone
are not likely to largely change the effective from the decay of
, the model with both additional Higgs doublet and
fourth-generation quarks can easily account for the possible large negative
value of without conflicting with other experimental
constraints. In this model, additional large CP violating effects may arise
from the flavor changing Yukawa interactions between neutral Higgs bosons and
the heavy fourth generation down type quark, which can modify the QCD penguin
contributions. With the constraints obtained from processes
such as and , this model can lead to the
effective to be as large as in the CP asymmetry of .Comment: 13 pages, 5 figures, references added, to appear in Eur.Phys.J.
A Precise Measurement of the Tau Lifetime
The tau lepton lifetime has been measured with the e+e- -> tau+tau- events
collected by the DELPHI detector at LEP in the years 1991-1995. Three different
methods have been exploited, using both one-prong and three-prong tau decay
channels. Two measurements have been made using events in which both taus decay
to a single charged particle. Combining these measurements gave tau_tau (1
prong) = 291.8 +/- 2.3 (stat) +/- 1.5 (sys) fs. A third measurement using taus
which decayed to three charged particles yielded tau_tau (3 prong) = 288.6 +/-
2.4 (stat) +/- 1.3 (sys) fs. These were combined with previous DELPHI results
to measure the tau lifetime, using the full LEP1 data sample, to be tau_tau =
290.9 +/- 1.4 (stat) +/- 1.0 (sys) fs.Comment: 27 pages, 7 figure
Recommendations for quantitative cerebral perfusion MRI using multi-timepoint arterial spin labeling:Acquisition, quantification, and clinical applications
Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision-making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi-timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post-labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi-timepoint data can be acquired in the same scan time as single-PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single-PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi-timepoint ASL and provides robust recommendations for acquiring high-quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi-timepoint ASL data. Furthermore, we review the potential clinical applications where multi-timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.</p
- …