200 research outputs found

    Axion-photon Couplings in Invisible Axion Models

    Get PDF
    We reexamine the axion-photon couplings in various invisible axion models motivated by the recent proposal of using optical interferometry at the ASST facility in the SSCL to search for axion. We illustrate that the assignment of U(1)PQU(1)_{PQ} charges for the fermion fields plays an important role in determining the couplings. Several simple non-minimal invisible axion models with suppressed and enhanced axion-photon couplings are constructed, respectively. We also discuss the implications of possible new experiments to detect solar axions by conversion to XX-rays in a static magnetic apparatus tracking the sun.Comment: 14 pages, LaTeX fil

    A straw drift chamber spectrometer for studies of rare kaon decays

    Full text link
    We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton straws, used in an experimental search for rare kaon decays. The experiment took place in the high-intensity neutral beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two analyzing dipoles, and redundant particle identification to remove backgrounds

    A Phenomenological Analysis of Gluon Mass Effects in Inclusive Radiative Decays of the J/ψ\rm{J/\psi} and $\Upsilon

    Full text link
    The shapes of the inclusive photon spectra in the processes \Jp \to \gamma X and \Up \to \gamma X have been analysed using all available experimental data. Relativistic, higher order QCD and gluon mass corrections were taken into account in the fitted functions. Only on including the gluon mass corrections, were consistent and acceptable fits obtained. Values of 0.721−0.068+0.0160.721^{+0.016}_{-0.068} GeV and 1.18−0.29+0.091.18^{+0.09}_{-0.29} GeV were found for the effective gluon masses (corresponding to Born level diagrams) for the \Jp and \Up respectively. The width ratios \Gamma(V \to {\rm hadrons})/\Gamma(V \to \gamma+ {\rm hadrons}) V=\Jp, \Up were used to determine αs(1.5GeV)\alpha_s(1.5 {\rm GeV}) and αs(4.9GeV)\alpha_s(4.9 {\rm GeV}). Values consistent with the current world average αs\alpha_s were obtained only when gluon mass correction factors, calculated using the fitted values of the effective gluon mass, were applied. A gluon mass ≃1\simeq 1 GeV, as suggested with these results, is consistent with previous analytical theoretical calculations and independent phenomenological estimates, as well as with a recent, more accurate, lattice calculation of the gluon propagator in the infra-red region.Comment: 50 pages, 11 figures, 15 table

    The GEM Project: an International Collaboration to Survey Galactic Radiation Emission

    Get PDF
    The GEM (Galactic Emission Mapping) project is an international collaboration established with the aim of surveying the full sky at long wavelengths with a multi-frequency radio telescope. A total of 745 hours of observation at 408 MHz were completed from an Equatorial site in Colombia. The observations cover the celestial band 0h<α<24h0^h < \alpha < 24^h, and −24∘ 22â€Č<ÎŽ<+35∘ 37â€Č-24^{\circ} \ 22^{\prime} < \delta < +35^{\circ} \ 37^{\prime}. Preliminary results of this partial survey will be discussed. A review of the instrumental setup and a ∌10∘\sim 10^{\circ} resolution sky map at 408 MHz is presented.Comment: 6 pages, Plain Latex + 1 (uuencoded) PostScript figure Fig. 1 and Fig. 2 not included, available from [email protected]

    Search for the Decay τ−→4pi−3π+(π0)Μτ\tau^{-}\to 4pi^{-}3\pi^{+}(\pi^{0})\nu_{\tau}

    Full text link
    We have searched for the decay of the tau lepton into seven charged particles and zero or one pi0. The data used in the search were collected with the CLEO II detector at the Cornell Electron Storage Ring (CESR) and correspond to an integrated luminosity of 4.61 fb^(-1). No evidence for a signal is found. Assuming all the charged particles are pions, we set an upper limit on the branching fraction, B(tau- -> 4pi- 3pi+ (pi0) nu_tau) < 2.4 x 10^(-6) at the 90% confidence level. This limit represents a significant improvement over the previous limit.Comment: 9 page postscript file, postscript file also available through http://w4.lns.cornell.edu/public/CLN

    Burden and risk factors for Pseudomonas aeruginosa community-acquired pneumonia:a Multinational Point Prevalence Study of Hospitalised Patients

    Get PDF
    Pseudornonas aeruginosa is a challenging bacterium to treat due to its intrinsic resistance to the antibiotics used most frequently in patients with community-acquired pneumonia (CAP). Data about the global burden and risk factors associated with P. aeruginosa-CAP are limited. We assessed the multinational burden and specific risk factors associated with P. aeruginosa-CAP. We enrolled 3193 patients in 54 countries with confirmed diagnosis of CAP who underwent microbiological testing at admission. Prevalence was calculated according to the identification of P. aeruginosa. Logistic regression analysis was used to identify risk factors for antibiotic-susceptible and antibiotic-resistant P. aeruginosa-CAP. The prevalence of P. aeruginosa and antibiotic-resistant P. aeruginosa-CAP was 4.2% and 2.0%, respectively. The rate of P. aeruginosa CAP in patients with prior infection/colonisation due to P. aeruginosa and at least one of the three independently associated chronic lung diseases (i.e. tracheostomy, bronchiectasis and/or very severe chronic obstructive pulmonary disease) was 67%. In contrast, the rate of P. aeruginosa-CAP was 2% in patients without prior P. aeruginosa infection/colonisation and none of the selected chronic lung diseases. The multinational prevalence of P. aeruginosa-CAP is low. The risk factors identified in this study may guide healthcare professionals in deciding empirical antibiotic coverage for CAP patients

    Development of a core descriptor set for Crohn's anal fistula

    Get PDF
    AIM: Crohn's anal fistula (CAF) is a complex condition, with no agreement on which patient characteristics should be routinely reported in studies. The aim of this study was to develop a core descriptor set of key patient characteristics for reporting in all CAF research. METHOD: Candidate descriptors were generated from published literature and stakeholder suggestions. Colorectal surgeons, gastroenterologists and specialist nurses in inflammatory bowel disease took part in three rounds of an international modified Delphi process using nine-point Likert scales to rank the importance of descriptors. Feedback was provided between rounds to allow refinement of the next ratings. Patterns in descriptor voting were assessed using principal component analysis (PCA). Resulting PCA groups were used to organize items in rounds two and three. Consensus descriptors were submitted to a patient panel for feedback. Items meeting predetermined thresholds were included in the final set and ratified at the consensus meeting. RESULTS: One hundred and thirty three respondents from 22 countries completed round one, of whom 67.0% completed round three. Ninety seven descriptors were rated across three rounds in 11 PCA-based groups. Forty descriptors were shortlisted. The consensus meeting ratified a core descriptor set of 37 descriptors within six domains: fistula anatomy, current disease activity and phenotype, risk factors, medical interventions for CAF, surgical interventions for CAF, and patient symptoms and impact on quality of life. CONCLUSION: The core descriptor set proposed for all future CAF research reflects characteristics important to gastroenterologists and surgeons. This might aid transparent reporting in future studies

    Study of the lineshape of the chi(c1) (3872) state

    Get PDF
    A study of the lineshape of the chi(c1) (3872) state is made using a data sample corresponding to an integrated luminosity of 3 fb(-1) collected in pp collisions at center-of-mass energies of 7 and 8 TeV with the LHCb detector. Candidate chi(c1)(3872) and psi(2S) mesons from b-hadron decays are selected in the J/psi pi(+)pi(-) decay mode. Describing the lineshape with a Breit-Wigner function, the mass splitting between the chi(c1 )(3872) and psi(2S) states, Delta m, and the width of the chi(c1 )(3872) state, Gamma(Bw), are determined to be (Delta m=185.598 +/- 0.067 +/- 0.068 Mev,)(Gamma BW=1.39 +/- 0.24 +/- 0.10 Mev,) where the first uncertainty is statistical and the second systematic. Using a Flatte-inspired model, the mode and full width at half maximum of the lineshape are determined to be (mode=3871.69+0.00+0.05 MeV.)(FWHM=0.22-0.04+0.13+0.07+0.11-0.06-0.13 MeV, ) An investigation of the analytic structure of the Flatte amplitude reveals a pole structure, which is compatible with a quasibound D-0(D) over bar*(0) state but a quasivirtual state is still allowed at the level of 2 standard deviations
    • 

    corecore