881 research outputs found

    Study of the liquid vapor equilibrium in the bromine-hydrobromic acid-water system

    Get PDF
    A glass ebullioscope was built and at atmospheric pressure, liquid-vapor equilibria relative to the Br2-HBr-H2O system, in the concentration range of interest for evaluation of the Mark 13 cycle was studied. Measurements were performed for the brome-azeotrope (HBr-H2O) pseudo-binary system and for the ternary system at temperatures lower than 125 C and in the bromine concentration range up to 13% wt

    BeppoSAX observations of the quasar Markarian 205

    Full text link
    We present the first BeppoSAX observation (0.1 to 220 keV) of the quasar Mrk 205. We have searched for the unusual Fe line profile claimed in the XMM-Newton spectrum which has been widely discussed in recent literature. We find no evidence for a broad, ionized Fe line component in our data. We detect for the first time a Compton hump in this object. Besides, when this component is included in the fit, the line strength diminishes, in agreement with a recent re-analysis of the XMM-Newton data, but with better constraints on the reflection component thanks to the PDS instrument (15-220 keV). We interpret this fact as another indication for illumination of a distant and cold material rather than reprocessing in the highly ionized inner parts of an accretion disk. We cannot constrain the presence of a high energy cutoff but we confirm the existence of a variable soft excess (one year timescale).Comment: 13 pages, 12 figures, accepted for publication in A&

    2003--2005 INTEGRAL and XMM-Newton observations of 3C 273

    Get PDF
    The aim of this paper is to study the evolution of the broadband spectrum of one of the brightest and nearest quasars 3C 273. We analyze the data obtained during quasi-simultaneous INTEGRAL and XMM monitoring of the blazar 3C 273 in 2003--2005 in the UV, X-ray and soft gamma-ray bands and study the results in the context of the long-term evolution of the source. The 0.2-100 keV spectrum of the source is well fitted by a combination of a soft cut-off power law and a hard power law. No improvement of the fit is achieved if one replaces the soft cut-off power law by either a blackbody, or a disk reflection model. During the observation period the source has reached the historically softest state in the hard X-ray domain with a photon index Γ=1.82±0.01\Gamma=1.82\pm 0.01. Comparing our data with available archived X-ray data from previous years, we find a secular evolution of the source toward softer X-ray emission (the photon index has increased by ΔΓ≃0.3−0.4\Delta\Gamma\simeq 0.3-0.4 over the last thirty years). We argue that existing theoretical models have to be significantly modified to account for the observed spectral evolution of the source.Comment: 11 pages, accepted to A&

    Simultaneous observations of the quasar 3C 273 with INTEGRAL, XMM-Newton and RXTE

    Full text link
    INTEGRAL has observed the bright quasar 3C 273 on 3 epochs in January 2003 as one of the first observations of the open programme. The observation on January 5 was simultaneous with RXTE and XMM-Newton observations. We present here a first analysis of the continuum emission as observed by these 3 satellites in the band from 3 keV to 500 keV. The continuum spectral energy distribution of 3C 273 was observed to be weak and steep in the high energies during this campaign. We present the actual status of the cross calibrations between the instruments on the three platforms using the calibrations available in June 2003.Comment: 4 figures, accepted for publication in A+A letter

    Compton reflection in AGN with Simbol-X

    Full text link
    AGN exhibit complex hard X-ray spectra. Our current understanding is that the emission is dominated by inverse Compton processes which take place in the corona above the accretion disk, and that absorption and reflection in a distant absorber play a major role. These processes can be directly observed through the shape of the continuum, the Compton reflection hump around 30 keV, and the iron fluorescence line at 6.4 keV. We demonstrate the capabilities of Simbol-X to constrain complex models for cases like MCG-05-23-016, NGC 4151, NGC 2110, and NGC 4051 in short (10 ksec) observations. We compare the simulations with recent observations on these sources by INTEGRAL, Swift and Suzaku. Constraining reflection models for AGN with Simbol-X will help us to get a clear view of the processes and geometry near to the central engine in AGN, and will give insight to which sources are responsible for the Cosmic X-ray background at energies above 20 keV.Comment: 4 pages, 1 figure, to appear in the proceedings of the second Simbol-X Symposium "Simbol-X - Focusing on the Hard X-ray Universe", AIP Conf. Proc. Series, P. Ferrando and J. Rodriguez ed

    INTEGRAL and XMM-Newton observations of the weak GRB 030227

    Full text link
    We present INTEGRAL and XMM-Newton observations of the prompt gamma-ray emission and the X-ray afterglow of GRB030227, the first GRB for which the quick localization obtained with the INTEGRAL Burst Alert System (IBAS) has led to the discovery of X-ray and optical afterglows. GRB030227 had a duration of about 20 s and a peak flux of 1.1 photons cm^-2 s^-1 in the 20-200 keV energy range. The time averaged spectrum can be fit by a single power law with photon index about 2 and we find some evidence for a hard to soft spectral evolution. The X-ray afterglow has been detected starting only 8 hours after the prompt emission, with a 0.2-10 keV flux decreasing as t^-1 from 1.3x10e-12 to 5x10e-13 erg cm^-2 s^-1. The afterglow spectrum is well described by a power law with photon index 1.94+/-0.05 modified by a redshifted neutral absorber with column density of several 10e22 cm^-2. A possible emission line at 1.67 keV could be due to Fe for a redshift z=3, consistent with the value inferred from the absorption.Comment: 16 pages, 5 figures, latex, Accepted for publication in The Astrophysical Journal Letter

    The efficient low-mass Seyfert MCG-05-23-016

    Full text link
    The Seyfert 1.9 galaxy MCG-05-23-016 has been shown to exhibit a complex X-ray spectrum. This source has moderate X-ray luminosity, hosts a comparably low-mass black hole, but accretes at a high Eddington rate, and allows us to study a super massive black hole in an early stage. Three observations of the INTEGRAL satellite simultaneous with pointed Swift/XRT observations performed from December 2006 to June 2007 are used in combination with public data from the INTEGRAL archive to study the variability of the hard X-ray components and to generate a high-quality spectrum from 1 to 150 keV. The AGN shows little variability in the hard X-ray spectrum, with some indication of a variation in the high-energy cut-off energy ranging from 50 keV to >>100 keV, with an electron plasma temperature in the 10 - 90 keV range. The reflection component is not evident and, if present, the reflected fraction can be constrained to R < 0.3 for the combined data set. Comparison to previous observations shows that the reflection component has to be variable. No variability in the UV and optical range is observed on a time scale of 1.5 years. The hard X-ray spectrum of MCG-05-23-016 appears to be stable with the luminosity and underlying power law varying moderately and the optical/UV flux staying constant. The spectral energy distribution appears to be similar to that of Galactic black hole systems, e.g. XTE 1118+480 in the low state. The AGN exhibits a remarkably high Eddington ratio of L(bol)/L(Edd)> 0.8 (or L(bol)/L(Edd) > 0.1, if we consider a higher mass of the central engine) and, at the same time, a low cut-off energy around 70 keV. Objects like MCG-05-23-016 might indicate the early stages of super massive black holes, in which a strong accretion flow feeds the central engine.Comment: 8 pages, 5 figures, accepted for publication in A&

    Clinical factors associated with the non-utilization of an anaesthesia incident reporting system

    Get PDF
    Background Incident reporting is a widely recommended method to measure undesirable events in anaesthesia. Under-utilization is a major weakness of voluntary incident reporting systems. Little is known about factors influencing reporting practices, particularly the clinical environment, anaesthesia team composition, severity of the incident, and perceived risk of litigation. The purpose of this study was to assess each of these, using an existing anaesthesia database. Methods We performed a retrospective cohort study and analysed 46 207 surgical patients. We used multivariate analysis to identify factors associated with the non-utilization of the reporting system. Results We found that in 7022 (15.1%) of the procedures performed, the incident reporting system was not used. Factors associated with the non-use of the system were regional anaesthesia/local anaesthesia, odds ratio (OR) 1.64 [95% confidence interval (CI) 1.03-2.62], emergency procedures OR 1.15 (95% CI: 1.05-1.27), and a consultant anaesthetist working without a trainee, OR 1.71 (95% CI: 1.03-2.82). In contrast, factors such as longer duration of surgery, OR 0.85 (95% CI: 0.76-0.94), the presence of a senior anaesthesia trainee, OR 0.86 (95% CI: 0.81-0.92), and the occurrence of severe complications with a high risk of litigation (i.e. death, nerve injuries) were less associated with a non-use of the reporting system, OR 0.65 (95% CI: 0.44-0.97). Team composition and time of day had no measurable impact on reporting practices. Conclusions Clinical factors play a significant role in the utilization of an anaesthesia incident reporting system and more particularly, severity of complications and higher liability risks which appear more as incentives than barriers to incident reportin
    • 

    corecore