881 research outputs found
Study of the liquid vapor equilibrium in the bromine-hydrobromic acid-water system
A glass ebullioscope was built and at atmospheric pressure, liquid-vapor equilibria relative to the Br2-HBr-H2O system, in the concentration range of interest for evaluation of the Mark 13 cycle was studied. Measurements were performed for the brome-azeotrope (HBr-H2O) pseudo-binary system and for the ternary system at temperatures lower than 125 C and in the bromine concentration range up to 13% wt
BeppoSAX observations of the quasar Markarian 205
We present the first BeppoSAX observation (0.1 to 220 keV) of the quasar Mrk
205. We have searched for the unusual Fe line profile claimed in the XMM-Newton
spectrum which has been widely discussed in recent literature. We find no
evidence for a broad, ionized Fe line component in our data. We detect for the
first time a Compton hump in this object. Besides, when this component is
included in the fit, the line strength diminishes, in agreement with a recent
re-analysis of the XMM-Newton data, but with better constraints on the
reflection component thanks to the PDS instrument (15-220 keV). We interpret
this fact as another indication for illumination of a distant and cold material
rather than reprocessing in the highly ionized inner parts of an accretion
disk. We cannot constrain the presence of a high energy cutoff but we confirm
the existence of a variable soft excess (one year timescale).Comment: 13 pages, 12 figures, accepted for publication in A&
2003--2005 INTEGRAL and XMM-Newton observations of 3C 273
The aim of this paper is to study the evolution of the broadband spectrum of
one of the brightest and nearest quasars 3C 273.
We analyze the data obtained during quasi-simultaneous INTEGRAL and XMM
monitoring of the blazar 3C 273 in 2003--2005 in the UV, X-ray and soft
gamma-ray bands and study the results in the context of the long-term evolution
of the source.
The 0.2-100 keV spectrum of the source is well fitted by a combination of a
soft cut-off power law and a hard power law. No improvement of the fit is
achieved if one replaces the soft cut-off power law by either a blackbody, or a
disk reflection model. During the observation period the source has reached the
historically softest state in the hard X-ray domain with a photon index
. Comparing our data with available archived X-ray data
from previous years, we find a secular evolution of the source toward softer
X-ray emission (the photon index has increased by
over the last thirty years). We argue that existing theoretical models have to
be significantly modified to account for the observed spectral evolution of the
source.Comment: 11 pages, accepted to A&
Simultaneous observations of the quasar 3C 273 with INTEGRAL, XMM-Newton and RXTE
INTEGRAL has observed the bright quasar 3C 273 on 3 epochs in January 2003 as
one of the first observations of the open programme. The observation on January
5 was simultaneous with RXTE and XMM-Newton observations. We present here a
first analysis of the continuum emission as observed by these 3 satellites in
the band from 3 keV to 500 keV. The continuum spectral energy distribution of
3C 273 was observed to be weak and steep in the high energies during this
campaign. We present the actual status of the cross calibrations between the
instruments on the three platforms using the calibrations available in June
2003.Comment: 4 figures, accepted for publication in A+A letter
Compton reflection in AGN with Simbol-X
AGN exhibit complex hard X-ray spectra. Our current understanding is that the
emission is dominated by inverse Compton processes which take place in the
corona above the accretion disk, and that absorption and reflection in a
distant absorber play a major role. These processes can be directly observed
through the shape of the continuum, the Compton reflection hump around 30 keV,
and the iron fluorescence line at 6.4 keV. We demonstrate the capabilities of
Simbol-X to constrain complex models for cases like MCG-05-23-016, NGC 4151,
NGC 2110, and NGC 4051 in short (10 ksec) observations. We compare the
simulations with recent observations on these sources by INTEGRAL, Swift and
Suzaku. Constraining reflection models for AGN with Simbol-X will help us to
get a clear view of the processes and geometry near to the central engine in
AGN, and will give insight to which sources are responsible for the Cosmic
X-ray background at energies above 20 keV.Comment: 4 pages, 1 figure, to appear in the proceedings of the second
Simbol-X Symposium "Simbol-X - Focusing on the Hard X-ray Universe", AIP
Conf. Proc. Series, P. Ferrando and J. Rodriguez ed
INTEGRAL and XMM-Newton observations of the weak GRB 030227
We present INTEGRAL and XMM-Newton observations of the prompt gamma-ray
emission and the X-ray afterglow of GRB030227, the first GRB for which the
quick localization obtained with the INTEGRAL Burst Alert System (IBAS) has led
to the discovery of X-ray and optical afterglows. GRB030227 had a duration of
about 20 s and a peak flux of 1.1 photons cm^-2 s^-1 in the 20-200 keV energy
range. The time averaged spectrum can be fit by a single power law with photon
index about 2 and we find some evidence for a hard to soft spectral evolution.
The X-ray afterglow has been detected starting only 8 hours after the prompt
emission, with a 0.2-10 keV flux decreasing as t^-1 from 1.3x10e-12 to 5x10e-13
erg cm^-2 s^-1. The afterglow spectrum is well described by a power law with
photon index 1.94+/-0.05 modified by a redshifted neutral absorber with column
density of several 10e22 cm^-2. A possible emission line at 1.67 keV could be
due to Fe for a redshift z=3, consistent with the value inferred from the
absorption.Comment: 16 pages, 5 figures, latex, Accepted for publication in The
Astrophysical Journal Letter
The efficient low-mass Seyfert MCG-05-23-016
The Seyfert 1.9 galaxy MCG-05-23-016 has been shown to exhibit a complex
X-ray spectrum. This source has moderate X-ray luminosity, hosts a comparably
low-mass black hole, but accretes at a high Eddington rate, and allows us to
study a super massive black hole in an early stage. Three observations of the
INTEGRAL satellite simultaneous with pointed Swift/XRT observations performed
from December 2006 to June 2007 are used in combination with public data from
the INTEGRAL archive to study the variability of the hard X-ray components and
to generate a high-quality spectrum from 1 to 150 keV. The AGN shows little
variability in the hard X-ray spectrum, with some indication of a variation in
the high-energy cut-off energy ranging from 50 keV to >>100 keV, with an
electron plasma temperature in the 10 - 90 keV range. The reflection component
is not evident and, if present, the reflected fraction can be constrained to R
< 0.3 for the combined data set. Comparison to previous observations shows that
the reflection component has to be variable. No variability in the UV and
optical range is observed on a time scale of 1.5 years. The hard X-ray spectrum
of MCG-05-23-016 appears to be stable with the luminosity and underlying power
law varying moderately and the optical/UV flux staying constant. The spectral
energy distribution appears to be similar to that of Galactic black hole
systems, e.g. XTE 1118+480 in the low state. The AGN exhibits a remarkably high
Eddington ratio of L(bol)/L(Edd)> 0.8 (or L(bol)/L(Edd) > 0.1, if we consider a
higher mass of the central engine) and, at the same time, a low cut-off energy
around 70 keV. Objects like MCG-05-23-016 might indicate the early stages of
super massive black holes, in which a strong accretion flow feeds the central
engine.Comment: 8 pages, 5 figures, accepted for publication in A&
Clinical factors associated with the non-utilization of an anaesthesia incident reporting system
Background Incident reporting is a widely recommended method to measure undesirable events in anaesthesia. Under-utilization is a major weakness of voluntary incident reporting systems. Little is known about factors influencing reporting practices, particularly the clinical environment, anaesthesia team composition, severity of the incident, and perceived risk of litigation. The purpose of this study was to assess each of these, using an existing anaesthesia database. Methods We performed a retrospective cohort study and analysed 46 207 surgical patients. We used multivariate analysis to identify factors associated with the non-utilization of the reporting system. Results We found that in 7022 (15.1%) of the procedures performed, the incident reporting system was not used. Factors associated with the non-use of the system were regional anaesthesia/local anaesthesia, odds ratio (OR) 1.64 [95% confidence interval (CI) 1.03-2.62], emergency procedures OR 1.15 (95% CI: 1.05-1.27), and a consultant anaesthetist working without a trainee, OR 1.71 (95% CI: 1.03-2.82). In contrast, factors such as longer duration of surgery, OR 0.85 (95% CI: 0.76-0.94), the presence of a senior anaesthesia trainee, OR 0.86 (95% CI: 0.81-0.92), and the occurrence of severe complications with a high risk of litigation (i.e. death, nerve injuries) were less associated with a non-use of the reporting system, OR 0.65 (95% CI: 0.44-0.97). Team composition and time of day had no measurable impact on reporting practices. Conclusions Clinical factors play a significant role in the utilization of an anaesthesia incident reporting system and more particularly, severity of complications and higher liability risks which appear more as incentives than barriers to incident reportin
- âŠ