159 research outputs found

    Diffusive propagation of cosmic rays from supernova remnants in the Galaxy. I: spectrum and chemical composition

    Full text link
    In this paper we investigate the effect of stochasticity in the spatial and temporal distribution of supernova remnants on the spectrum and chemical composition of cosmic rays observed at Earth. The calculations are carried out for different choices of the diffusion coefficient D(E) experienced by cosmic rays during propagation in the Galaxy. In particular, at high energies we assume that D(E)\sim E^{\delta}, with δ=1/3\delta=1/3 and δ=0.6\delta=0.6 being the reference scenarios. The large scale distribution of supernova remnants in the Galaxy is modeled following the distribution of pulsars, with and without accounting for the spiral structure of the Galaxy. We find that the stochastic fluctuations induced by the spatial and temporal distribution of supernovae, together with the effect of spallation of nuclei, lead to mild but sensible violations of the simple, leaky-box-inspired rule that the spectrum observed at Earth is N(E)EαN(E)\propto E^{-\alpha} with α=γ+δ\alpha=\gamma+\delta, where γ\gamma is the slope of the cosmic ray injection spectrum at the sources. Spallation of nuclei, even with the small rates appropriate for He, may account for slight differences in spectral slopes between different nuclei, providing a possible explanation for the recent CREAM observations. For δ=1/3\delta=1/3 we find that the slope of the proton and helium spectra are 2.67\sim 2.67 and 2.6\sim 2.6 respectively at energies above 1 TeV (to be compared with the measured values of 2.66±0.022.66\pm 0.02 and 2.58±0.022.58\pm 0.02). For δ=0.6\delta=0.6 the hardening of the He spectra is not observed. We also comment on the effect of time dependence of the escape of cosmic rays from supernova remnants, and of a possible clustering of the sources in superbubbles. In a second paper we will discuss the implications of these different scenarios for the anisotropy of cosmic rays.Comment: 28 pages, To appear in JCA

    The spiritual organization: critical reflections on the instrumentality of workplace spirituality

    Get PDF
    Authors' draft of article. Final version published by Routledge in Journal of Management, Spirituality and Religion available online at: http://www.tandf.co.uk/journals/titles/14766086.aspThis paper offers a theoretical contribution to the current debate on workplace spirituality by: (a) providing a selective critical review of scholarship, research and corporate practices which treat workplace spirituality in performative terms, that is, as a resource or means to be manipulated instrumentally and appropriated for economic ends; (b) extending Ezioni’s analysis of complex organizations and proposing a new category, the ‘spiritual organization’, and; (c) positing three alternative positions with respect to workplace spirituality that follow from the preceding critique. The spiritual organization can be taken to represent the development of a trajectory of social technologies that have sought, incrementally, to control the bodies, minds, emotions and souls of employees. Alternatively, it might be employed to conceptualize the way in which employees use the workplace as a site for pursuing their own spiritualities (a reverse instrumentalism). Finally, we consider the possible incommensurability of ‘work organization’ and ‘spirituality’ discourses

    Social learning in LEADER: Exogenous, endogenous and hybrid evaluation in rural development

    Get PDF
    This paper considers the relationship between the centralised exogenous, institutions and the embedded, endogenous institutions of rural governance in Europe through an examination the evaluation procedures of the European LEADER programme. LEADER is presented in the literature as progressive in terms of innovation and stakeholder engagement. Yet while the planning and management of LEADER embraces heterogeneity and participation, programmatic evaluation is centralised and held at arms length from delivery organisations. The paper reviews previous efforts to improve evaluation in LEADER and considers alternative strategies for evaluation, contrasting LEADER practice with participatory evaluation methodologies in the wider international context. Can evaluation in itself be valuable as a mode of social learning and hence a driver for endogenous development in rural communities in Europe? The paper concludes by examining the challenges in producing a hybrid form of evaluation which accommodates endogenous and exogenous values

    Rapid isolation and profiling of a diverse panel of human monoclonal antibodies targeting the SARS-CoV-2 spike protein

    Get PDF
    Antibodies are a principal determinant of immunity for most RNA viruses and have promise to reduce infection or disease during major epidemics. The novel coronavirus SARS-CoV-2 has caused a global pandemic with millions of infections and hundreds of thousands of deaths to date1,2. In response, we used a rapid antibody discovery platform to isolate hundreds of human monoclonal antibodies (mAbs) against the SARS-CoV-2 spike (S) protein. We stratify these mAbs into five major classes on the basis of their reactivity to subdomains of S protein as well as their cross-reactivity to SARS-CoV. Many of these mAbs inhibit infection of authentic SARS-CoV-2 virus, with most neutralizing mAbs recognizing the receptor-binding domain (RBD) of S. This work defines sites of vulnerability on SARS-CoV-2 S and demonstrates the speed and robustness of advanced antibody discovery platforms

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS drift-tube chamber local trigger with cosmic rays

    Get PDF
    The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams

    Observation of a new boson at a mass of 125 GeV with the CMS experiment at the LHC

    Get PDF
    corecore