57 research outputs found

    ERS statement on standardisation of cardiopulmonary exercise testing in chronic lung diseases

    Get PDF
    The objective of this document was to standardise published cardiopulmonary exercise testing (CPET) protocols for improved interpretation in clinical settings and multicentre research projects. This document: 1) summarises the protocols and procedures used in published studies focusing on incremental CPET in chronic lung conditions; 2) presents standard incremental protocols for CPET on a stationary cycle ergometer and a treadmill; and 3) provides patients’ perspectives on CPET obtained through an online survey supported by the European Lung Foundation. We systematically reviewed published studies obtained from EMBASE, Medline, Scopus, Web of Science and the Cochrane Library from inception to January 2017. Of 7914 identified studies, 595 studies with 26 523 subjects were included. The literature supports a test protocol with a resting phase lasting at least 3 min, a 3-min unloaded phase, and an 8- to 12-min incremental phase with work rate increased linearly at least every minute, followed by a recovery phase of at least 2–3 min. Patients responding to the survey (n=295) perceived CPET as highly beneficial for their diagnostic assessment and informed the Task Force consensus. Future research should focus on the individualised estimation of optimal work rate increments across different lung diseases, and the collection of robust normative data.The document facilitates standardisation of conducting, reporting and interpreting cardiopulmonary exercise tests in chronic lung diseases for comparison of reference data, multi-centre studies and assessment of interventional efficacy. http://bit.ly/31SXeB

    Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system

    Get PDF
    This study investigated the performance of the portable Cortex Metamax 3B (MM3B) automated gas analysis system during both simulated and human exercise using adolescents. Repeated measures using a Gas Exchange System Validator (GESV) across a range of simulated metabolic rates, showed the MM3B to be adequately reliable (both percentage errors, and percentage technical error of measurements <2%) for measuring expired ventilation (VE), oxygen consumption (VO2), and carbon dioxide production (VCO2). Over a 3 h period, the MM3B was shown to be acceptably stable in measuring gas fractions, as well as VE, VO2, and VCO2 generated by the GESV, especially at moderate and high metabolic rates (drifts <2% and of minor physiological significance). Using eight healthy adolescents during rest, moderate, and vigorous cycle ergometry, the validity of the MM3B was tested against the primary criterion Douglas bag method (DBM) and a secondary criterion machine known to be accurate, the Jaeger Oxycon Pro system. No significant errors in VE were noted, yet the MM3B significantly overestimated both VO2 and VCO2 by approximately 10–17% at moderate and vigorous exercise as compared to the DBM and at all exercise levels compared to the Oxycon Pro. No significant differences were seen in any metabolic variable between the two criterion systems (DBM and Oxycon Pro). It is concluded the MM3B produces acceptably stable and reliable results, but is not adequately valid during moderate and vigorous exercise without some further correction of VO2 and VCO2

    Body composition and physical activity in New Zealand Maori, Pacific and European children aged 5-14 years

    Get PDF
    Body fatness and the components of energy expenditure in children aged 5-14 years were investigated. In a group of seventy-nine healthy children (thirty-nine female, forty male), mean age 10-0 (SD 2-8) years, comprising twenty-seven Maori, twenty-six Pacific Island and twenty-six European, total energy expenditure (TEE) was determined over 10d using the doubly-labelled water method. Resting metabolic rate (RMR) was measured by indirect calorimetry and physical activity level (PAL) was calculated as TEE:RMR. Fat-free mass (FFM), and hence fat mass, was derived from the O-18-dilution space using appropriate values for FFM hydration in children. Qualitative information on physical activity patterns was obtained by questionnaire. Maori and Pacific children had a higher BMI than European children (P< 0.003), but % body fat was similar for the three ethnic groups. The % body fat increased with age for girls (r 0-42, P=0008), but not for boys. Ethnicity was not a significant predictor of RMR adjusted for FFM and fat mass. TEE and PAL, adjusted for body weight and age, were higher in Maori than European children (

    Developing Pulmonary Vasculopathy in Systemic Sclerosis, Detected with Non-Invasive Cardiopulmonary Exercise Testing

    Get PDF
    BACKGROUND: Patients with systemic sclerosis (SSc) may develop exercise intolerance due to musculoskeletal involvement, restrictive lung disease, left ventricular dysfunction, or pulmonary vasculopathy (PV). The latter is particularly important since it may lead to lethal pulmonary arterial hypertension (PAH). We hypothesized that abnormalities during cardiopulmonary exercise testing (CPET) in patients with SSc can identify PV leading to overt PAH. METHODS: Thirty SSc patients from the Harbor-UCLA Rheumatology clinic, not clinically suspected of having significant pulmonary vascular disease, were referred for this prospective study. Resting pulmonary function and exercise gas exchange were assessed, including peakVO2, anaerobic threshold (AT), heart rate-VO2 relationship (O2-pulse), exercise breathing reserve and parameters of ventilation-perfusion mismatching, as evidenced by elevated ventilatory equivalent for CO2 (VE/VCO2) and reduced end-tidal pCO2 (PETCO2) at the AT. RESULTS: Gas exchange patterns were abnormal in 16 pts with specific cardiopulmonary disease physiology: Eleven patients had findings consistent with PV, while five had findings consistent with left-ventricular dysfunction (LVD). Although both groups had low peak VO2 and AT, a higher VE/VCO2 at AT and decreasing PETCO2 during early exercise distinguished PV from LVD. CONCLUSIONS: Previously undiagnosed exercise impairments due to LVD or PV were common in our SSc patients. Cardiopulmonary exercise testing may help to differentiate and detect these disorders early in patients with SSc

    Determinants of exercise peak arterial blood pressure, circulatory power, and exercise cardiac power in a population based sample of Finnish male and female aged 30 to 47 years: the Cardiovascular Risk in Young Finns Study

    Get PDF
    Background Novel parameters derived from peak maximal oxygen uptake (VO2) and exercise arterial blood pressure, such as peak circulatory power (CP) and exercise cardiac power (ECP), can be used in the risk assessment of cardiovascular disease and stroke. However, the determinants of these factors are poorly characterized in the general population. Methods We assessed peak arterial blood pressure, CP and ECP with standardized cardiopulmonary exercise test (CPET) on 281 female and 257 male participants of the Cardiovascular Risk in Young Finns Study. The subjects were aged 30–47 years. Peak VO2 as well as systolic and diastolic arterial blood pressures were measured to calculate peak mean arterial pressure, CP and ECP. These parameters were assessed for correlation with sex, age, height, weight, waist-to-hip ratio, smoking, physical activity index (PAI), fasting insulin and glucose levels as well as the use of antihypertensive treatment. Results Sex, age and weight explained 36% of the variation in peak systolic blood pressure, and these factors in combination with height and the use of antihypertensive treatment explained 13% of the variation in peak diastolic blood pressure. Sex, height, weight, waist-to-hip ratio, PAI and smoking explained 49% − 52% of the variation in peak CP. Sex, age, height, weight, waist-to-hip ratio, PAI, smoking and insulin levels explained 21% − 49% of variation in ECP. Conclusions Subject demographics and lifestyle-related factors should be taken into account when exercise blood pressure response, CP and ECP are used to evaluate patients’ cardiac function in CPET.BioMed Central open acces
    • 

    corecore