12 research outputs found

    HYpofractionated, dose-redistributed RAdiotherapy with protons and photons to combat radiation-induced immunosuppression in head and neck squamous cell carcinoma: study protocol of the phase I HYDRA trial

    Get PDF
    Background: Radiotherapy (RT) is the standard of care for most advanced head and neck squamous cell carcinoma (HNSCC) and results in an unfavorable 5-year overall survival of 40%. Despite strong biological rationale, combining RT with immune checkpoint inhibitors does not result in a survival benefit. Our hypothesis is that the combination of these individually effective treatments fails because of radiation-induced immunosuppression and lymphodepletion. By integrating modern radiobiology and innovative radiotherapy concepts, the patient’s immune system could be maximally retained by (1) increasing the dose per fraction so that the total dose and number of fractions can be reduced (HYpofractionation), (2) redistributing the radiation dose towards a higher peak dose within the tumor center and a lowered elective lymphatic field dose (Dose-redistribution), and (3) using RAdiotherapy with protons instead of photons (HYDRA). Methods: The primary aim of this multicenter study is to determine the safety of HYDRA proton- and photon radiotherapy by conducting two parallel phase I trials. Both HYDRA arms are randomized with the standard of care for longitudinal immune profiling. There will be a specific focus on actionable immune targets and their temporal patterns that can be tested in future hypofractionated immunoradiotherapy trials. The HYDRA dose prescriptions (in 20 fractions) are 40 Gy elective dose and 55 Gy simultaneous integrated boost on the clinical target volume with a 59 Gy focal boost on the tumor center. A total of 100 patients (25 per treatment group) will be recruited, and the final analysis will be performed one year after the last patient has been included. Discussion: In the context of HNSCC, hypofractionation has historically only been reserved for small tumors out of fear for late normal tissue toxicity. To date, hypofractionated radiotherapy may also be safe for larger tumors, as both the radiation dose and volume can be reduced by the combination of advanced imaging for better target definition, novel accelerated repopulation models and high-precision radiation treatment planning and dose delivery. HYDRA’s expected immune-sparing effect may lead to improved outcomes by allowing for future effective combination treatment with immunotherapy. Trial registration: The trial is registered at ClinicalTrials.gov; NCT05364411 (registered on May 6th, 2022)

    Discovery of carbon radio recombination lines in absorption towards Cygnus A

    Get PDF
    We present the first detection of carbon radio recombination line absorption along the line of sight to Cygnus A. The observations were carried out with the Low Frequency Array in the 33–57 MHz range. These low-frequency radio observations provide us with a new line of sight to study the diffuse, neutral gas in our Galaxy. To our knowledge this is the first time that foreground Milky Way recombination line absorption has been observed against a bright extragalactic background source. By stacking 48 carbon α lines in the observed frequency range we detect carbon absorption with a signal-to-noise ratio of about 5. The average carbon absorption has a peak optical depth of 2 × 10−4, a line width of 10 km s−1 and a velocity of +4 km s−1 with respect to the local standard of rest. The associated gas is found to have an electron temperature Te ∌ 110 K and density ne ∌ 0.06 cm−3. These properties imply that the observed carbon α absorption likely arises in the cold neutral medium of the Orion arm of the Milky Way. Hydrogen and helium lines were not detected to a 3σ peak optical depth limit of 1.5 × 10−4 for a 4 km s−1 channel width. Radio recombination lines associated with Cygnus A itself were also searched for, but are not detected. We set a 3σ upper limit of 1.5 × 10−4 for the peak optical depth of these lines for a 4 km s−1 channel width

    The LOFAR long baseline snapshot calibrator survey

    Get PDF
    13 pages, 9 figures. Accepted for publication in Astronomy and AstrophysicsInternational audienceAims. An efficient means of locating calibrator sources for International LOFAR is developed and used to determine the average density of usable calibrator sources on the sky for subarcsecond observations at 140 MHz. Methods. We used the multi-beaming capability of LOFAR to conduct a fast and computationally inexpensive survey with the full International LOFAR array. Sources were pre-selected on the basis of 325 MHz arcminute-scale flux density using existing catalogues. By observing 30 different sources in each of the 12 sets of pointings per hour, we were able to inspect 630 sources in two hours to determine if they possess a sufficiently bright compact component to be usable as LOFAR delay calibrators. Results. Over 40% of the observed sources are detected on multiple baselines between international stations and 86 are classified as satisfactory calibrators. We show that a flat low-frequency spectrum (from 74 to 325 MHz) is the best predictor of compactness at 140 MHz. We extrapolate from our sample to show that the density of calibrators on the sky that are sufficiently bright to calibrate dispersive and non-dispersive delays for the International LOFAR using existing methods is 1.0 per square degree. Conclusions. The observed density of satisfactory delay calibrator sources means that observations with International LOFAR should be possible at virtually any point in the sky, provided that a fast and efficient search using the methodology described here is conducted prior to the observation to identify the best calibrator
    corecore