24 research outputs found

    Continuous Pneumatic Regulation of Tracheal Cuff Pressure to Decrease Ventilator-associated Pneumonia in Trauma Patients Who Were Mechanically Ventilated

    No full text
    International audienceBackground: Ventilator-associated pneumonia (VAP) is the most frequent health care-associated infection in severely ill patients, and aspiration of contaminated oropharyngeal content around the cuff of the tracheal tube is the main route of contamination.Research question: Is continuous regulation of tracheal cuff pressure using a pneumatic device superior to manual assessment three times daily using a portable manometer (routine care) in preventing VAP in patients with severe trauma?Study design and methods: In this open-label, randomized controlled superiority trial conducted in 13 French ICUs, adults (age ≥ 18 years) with severe trauma (Injury Severity Score > 15) and requiring invasive mechanical ventilation for ≥ 48 h were enrolled. Patients were randomly assigned (1:1) via a secure Web-based random number generator in permuted blocks of variable sizes to one of two groups according to the method of tracheal cuff pressure control. The primary outcome was the proportion of patients developing VAP within 28 days following the tracheal intubation, as determined by two assessors masked to group assignment, in the modified intention-to-treat population. This study is closed to new participants.Results: A total of 434 patients were recruited between July 31, 2015, and February 15, 2018, of whom 216 were assigned to the intervention group and 218 to the control group. Seventy-three patients (33.8%) developed at least one episode of VAP within 28 days following the tracheal intubation in the intervention group compared with 64 patients (29.4%) in the control group (adjusted subdistribution hazard ratio, 0.96; 95% CI, 0.76-1.20; P = .71). No serious adverse events related to the use of the pneumatic device were noted.Interpretation: Continuous regulation of cuff pressure of the tracheal tube using a pneumatic device was not superior to routine care in preventing VAP in patients with severe trauma.Clinical trial registration: ClinicalTrials.gov; No.: NCT02534974; URL: www.clinicaltrials.gov

    Spontaneous-Breathing Trials with Pressure-Support Ventilation or a T-Piece

    No full text
    International audienceBackground: Spontaneous-breathing trials can be performed with the use of either pressure-support ventilation (PSV) or a T-piece. Whether PSV trials may result in a shorter time to tracheal extubation than T-piece trials, without resulting in a higher risk of reintubation, among patients who have a high risk of extubation failure is unknown.Methods: In this multicenter, open-label trial, we randomly assigned patients who had a high risk of extubation failure (i.e., were >65 years of age or had an underlying chronic cardiac or respiratory disease) to undergo spontaneous-breathing trials performed with the use of either PSV (with a pressure-support level of 8 cm of water and no positive end-expiratory pressure) or a T-piece. The primary outcome was the total time without exposure to invasive ventilation (reported as the number of ventilator-free days) at day 28 after the initial spontaneous-breathing trial. Secondary outcomes included extubation within 24 hours and extubation within 7 days after the initial spontaneous-breathing trial, as well as reintubation within 7 days after extubation.Results: A total of 969 patients (484 in the PSV group and 485 in the T-piece group) were included in the analysis. At day 28, the median number of ventilator-free days was 27 (interquartile range, 24 to 27) in the PSV group and 27 (interquartile range, 23 to 27) in the T-piece group (difference, 0 days; 95% confidence interval [CI], -0.5 to 1; P = 0.31). Extubation was performed within 24 hours in 376 patients (77.7%) in the PSV group and in 350 patients (72.2%) in the T-piece group (difference, 5.5 percentage points; 95% CI, 0.01 to 10.9), and extubation was performed within 7 days in 473 patients (97.7%) and 458 patients (94.4%), respectively (difference, 3.3 percentage points; 95% CI, 0.8 to 5.9). Reintubation was performed in 72 of 481 patients (14.9%) in the PSV group and in 65 of 477 patients (13.6%) in the T-piece group (difference, 1.3 percentage points; 95% CI, -3.1 to 5.8). Cardiac or respiratory arrest was a reason for reintubation in 9 patients (3 in the PSV group and 6 in the T-piece group).Conclusions: Among patients who had a high risk of extubation failure, spontaneous-breathing trials performed with PSV did not result in significantly more ventilator-free days at day 28 than spontaneous-breathing trials performed with a T-piece. (Supported by the French Ministry of Health; TIP-EX ClinicalTrials.gov number, NCT04227639.)

    Spontaneous-Breathing Trials with Pressure-Support Ventilation or a T-Piece

    No full text
    International audienceBackground: Spontaneous-breathing trials can be performed with the use of either pressure-support ventilation (PSV) or a T-piece. Whether PSV trials may result in a shorter time to tracheal extubation than T-piece trials, without resulting in a higher risk of reintubation, among patients who have a high risk of extubation failure is unknown.Methods: In this multicenter, open-label trial, we randomly assigned patients who had a high risk of extubation failure (i.e., were >65 years of age or had an underlying chronic cardiac or respiratory disease) to undergo spontaneous-breathing trials performed with the use of either PSV (with a pressure-support level of 8 cm of water and no positive end-expiratory pressure) or a T-piece. The primary outcome was the total time without exposure to invasive ventilation (reported as the number of ventilator-free days) at day 28 after the initial spontaneous-breathing trial. Secondary outcomes included extubation within 24 hours and extubation within 7 days after the initial spontaneous-breathing trial, as well as reintubation within 7 days after extubation.Results: A total of 969 patients (484 in the PSV group and 485 in the T-piece group) were included in the analysis. At day 28, the median number of ventilator-free days was 27 (interquartile range, 24 to 27) in the PSV group and 27 (interquartile range, 23 to 27) in the T-piece group (difference, 0 days; 95% confidence interval [CI], -0.5 to 1; P = 0.31). Extubation was performed within 24 hours in 376 patients (77.7%) in the PSV group and in 350 patients (72.2%) in the T-piece group (difference, 5.5 percentage points; 95% CI, 0.01 to 10.9), and extubation was performed within 7 days in 473 patients (97.7%) and 458 patients (94.4%), respectively (difference, 3.3 percentage points; 95% CI, 0.8 to 5.9). Reintubation was performed in 72 of 481 patients (14.9%) in the PSV group and in 65 of 477 patients (13.6%) in the T-piece group (difference, 1.3 percentage points; 95% CI, -3.1 to 5.8). Cardiac or respiratory arrest was a reason for reintubation in 9 patients (3 in the PSV group and 6 in the T-piece group).Conclusions: Among patients who had a high risk of extubation failure, spontaneous-breathing trials performed with PSV did not result in significantly more ventilator-free days at day 28 than spontaneous-breathing trials performed with a T-piece. (Supported by the French Ministry of Health; TIP-EX ClinicalTrials.gov number, NCT04227639.)

    Blood Monocyte Phenotype Is A Marker of Cardiovascular Risk in Type 2 Diabetes

    No full text
    International audienceBACKGROUND: Diabetes is a major risk factor for atherosclerotic cardiovascular diseases with a 2-fold higher risk of cardiovascular events in people with diabetes compared with those without. Circulating monocytes are inflammatory effector cells involved in both type 2 diabetes (T2D) and atherogenesis. METHODS: We investigated the relationship between circulating monocytes and cardiovascular risk progression in people with T2D, using phenotypic, transcriptomic, and metabolomic analyses. cardiovascular risk progression was estimated with coronary artery calcium score in a cohort of 672 people with T2D. RESULTS: Coronary artery calcium score was positively correlated with blood monocyte count and frequency of the classical monocyte subtype. Unsupervised k-means clustering based on monocyte subtype profiles revealed 3 main endotypes of people with T2D at varying risk of cardiovascular events. These observations were confirmed in a validation cohort of 279 T2D participants. The predictive association between monocyte count and major adverse cardiovascular events was validated through an independent prospective cohort of 757 patients with T2D. Integration of monocyte transcriptome analyses and plasma metabolomes showed a disruption of mitochondrial pathways (tricarboxylic acid cycle, oxidative phosphorylation pathway) that underlined a proatherogenic phenotype. CONCLUSIONS: In this study, we provide evidence that frequency and monocyte phenotypic profile are closely linked to cardiovascular risk in patients with T2D. The assessment of monocyte frequency and count is a valuable predictive marker for risk of cardiovascular events in patients with T2D. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT0435386

    CT Imaging Assessment of Response to Treatment in Allergic Bronchopulmonary Aspergillosis in Adults With Bronchial Asthma

    No full text
    International audienceBackgroundOne of the major challenges in managing allergic bronchopulmonary aspergillosis (ABPA) remains consistent and reproducible assessment of response to treatment.Research questionWhat are the most relevant changes in computed tomography (CT-scan) parameters over time for assessing response to treatment?Study Design and MethodsIn this ancillary study of a randomized clinical trial (NEBULAMB), asthmatic patients with available CT-scan and without exacerbation during a 4-month ABPA exacerbation treatment period (corticosteroids and itraconazole) were included. Changed CT-scan parameters were assessed by systematic analyses of CT-scan findings at initiation (M0) and end of treatment (M4). CT-scans were assessed by two radiologists blinded to the clinical data. Radiological parameters were determined by selecting those showing significant changes over time. Improvement of at least one, without worsening of the others, defined the radiological response. Agreement between radiological changes, clinical and immunologic responses was likewise investigated.ResultsAmong the 139 originally randomized patients, 132 were included. We identified 5 CT-scan parameters showing significant changes at M4: mucoid impaction extent, mucoid impaction density, centrilobular micronodules, consolidation/ground-glass opacities and bronchial wall thickening (P<0.05). These changes were only weakly associated with one another, except for mucoid impaction extent and density. No agreement was observed between clinical or immunologic and radiological responses, assessed as an overall response, or considering each of the parameters (Cohen’s κ, -0.01 to 0.24).InterpretationChanges in extent and density of mucoid impactions, centrilobular micronodules, consolidation/ground-glass opacities and thickening of the bronchial walls were found to be the most relevant CT-scan parameters to assess radiological response to treatment. A clinical, immunologic and radiological multidimensional approach should be adopted to assess outcomes, probably with a composite definition of response to treatment

    The LHCb upgrade I

    No full text
    International audienceThe LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software

    The LHCb upgrade I

    No full text
    International audienceThe LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software

    The LHCb upgrade I

    No full text
    International audienceThe LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software
    corecore