492 research outputs found

    Prevalence and characteristics of non-O157 shiga toxin-producing Escherichia coli (STEC) and Escherichia coli O157 in fattening pigs at slaughter in Switzerland

    Get PDF
    Feacal samples from 630 slaughtered healthy pigs were examined with the aim: (i) to monitor the shedding of non-O157 STEC and E. coli O157; (ii) to further characterize isolated strains; and (iii) to discuss the results obtained with their relevance to food safety. The percentage of the 630 samples testing positive for STEC by polymerase chain reaction was 22.2%. The 32 isolated stx positive strains (31 sorbitol-positive) belonged to non-O157 STEC and comprised ten serotypes. Stx1, stx2, and both toxin genes were detected in 3%, 97%, and 0% of strains. Among stx2-positive strains, 29 were positive for stx2e, one for stx2/stx2e, and one for stx2c/stx2e. The percentage of the 630 samples testing positive for E. coli O157 by polymerase chain reaction was 7.5%. The 31 isolated rfbE PCR positive strains tested negative for stx genes. However, four strains harbored eae and were classified as EPEC

    Concomitant statin use does not impair the clinical outcome of patients with diffuse large B cell lymphoma treated with rituximab-CHOP

    Get PDF
    Preclinical data indicated a detrimental effect of statins on the anti-lymphoma activity of rituximab. We evaluated the impact of concomitant statin medication on the response and survival of patients with diffuse large B cell lymphoma (DLBCL) receiving rituximab-cyclophosphamide, doxorubicin, vincristine, prednisone (R-CHOP) as first-line therapy. Medical histories of patients with DLBCL who were treated with R-CHOP as first-line therapy were assessed for concomitant statin use, response after completion of chemotherapy, event-free survival (EFS), and overall survival (OS). Furthermore, 2-[18F]fluor-2-deoxyglucose (FDG)-PET/CT results after completion of first-line therapy were compared between the groups. Overall, 145 patients with DLBCL treated with R-CHOP from January 2001 to December 2009 were analyzed. Twenty-one (15%) patients received statins throughout therapy. Five-year EFS was 67.3% in patients without statins compared with 79% in patients receiving statins during R-CHOP (HR, 0.47; 95% CI, 0.15-1.54, p = 0.2). Five-year OS was 81.4% for patients without statins compared with 93.3% for patients taking statins (HR, 0.58; 95% CI 0.07-4.55, p = 0.6). There were no statistically significant differences in the rates of complete remissions between the two groups (75% in the non-statin group versus 86% in the statin group, p = 0.45). A trend toward a lower rate of complete metabolic responses in FDG-PET/CT after chemotherapy was seen in patients without statin medication compared with the patients taking statins (84% versus 92%, p = 0.068). Concomitant statin use had no adverse impact on response to chemotherapy, EFS, and OS in patients treated with R-CHOP for DLBC

    First do no harm - The impact of financial incentives on dental X-rays

    Get PDF
    This article assesses the impact of dentist remuneration on the incidence of potentially harmful dental X-rays. We use unique panel data which provide details of 1.3 million treatment claims by Scottish NHS dentists made between 1998 and 2007. Controlling for unobserved heterogeneity of both patients and dentists we estimate a series of fixed-effects models that are informed by a theoretical model of X-ray delivery and identify the effects on dental X-raying of dentists moving from a fixed salary to fee-for-service and patients moving from co-payment to exemption. We establish that there are significant increases in X-rays when dentists receive fee-for-service rather than salary payments and when patients are made exempt from payment

    Genetic inhibition of neurotransmission reveals role of glutamatergic input to dopamine neurons in high-effort behavior

    Get PDF
    Midbrain dopamine neurons are crucial for many behavioral and cognitive functions. As the major excitatory input, glutamatergic afferents are important for control of the activity and plasticity of dopamine neurons. However, the role of glutamatergic input as a whole onto dopamine neurons remains unclear. Here we developed a mouse line in which glutamatergic inputs onto dopamine neurons are specifically impaired, and utilized this genetic model to directly test the role of glutamatergic inputs in dopamine-related functions. We found that while motor coordination and reward learning were largely unchanged, these animals showed prominent deficits in effort-related behavioral tasks. These results provide genetic evidence that glutamatergic transmission onto dopaminergic neurons underlies incentive motivation, a willingness to exert high levels of effort to obtain reinforcers, and have important implications for understanding the normal function of the midbrain dopamine system.Fil: Hutchison, M. A.. National Institutes of Health; Estados UnidosFil: Gu, X.. National Institutes of Health; Estados UnidosFil: Adrover, Martín Federico. National Institutes of Health; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Investigaciones en Ingeniería Genética y Biología Molecular "Dr. Héctor N. Torres"; ArgentinaFil: Lee, M. R.. National Institutes of Health; Estados UnidosFil: Hnasko, T. S.. University of California at San Diego; Estados UnidosFil: Alvarez, V. A.. National Institutes of Health; Estados UnidosFil: Lu, W.. National Institutes of Health; Estados Unido

    Beyond the required LISA free-fall performance: new LISA pathfinder results down to 20  μHz

    Get PDF
    In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20  μHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05)  fm s^{-2}/sqrt[Hz] above 2 mHz and (6±1)×10  fm s^{-2}/sqrt[Hz] at 20  μHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency

    A strategy to characterize the LISA-Pathfinder cold gas thruster system

    Get PDF
    The cold gas micro-propulsion system that will be used during the LISA-Pathfinder mission will be one of the most important component used to ensure the "free-fall" of the enclosed test masses. In this paper we present a possible strategy to characterize the effective direction and amplitude gain of each of the 6 thrusters of this system

    Free-flight experiments in LISA Pathfinder

    Get PDF
    The LISA Pathfinder mission will demonstrate the technology of drag-free test masses for use as inertial references in future space-based gravitational wave detectors. To accomplish this, the Pathfinder spacecraft will perform drag-free flight about a test mass while measuring the acceleration of this primary test mass relative to a second reference test mass. Because the reference test mass is contained within the same spacecraft, it is necessary to apply forces on it to maintain its position and attitude relative to the spacecraft. These forces are a potential source of acceleration noise in the LISA Pathfinder system that are not present in the full LISA configuration. While LISA Pathfinder has been designed to meet it's primary mission requirements in the presence of this noise, recent estimates suggest that the on-orbit performance may be limited by this `suspension noise'. The drift-mode or free-flight experiments provide an opportunity to mitigate this noise source and further characterize the underlying disturbances that are of interest to the designers of LISA-like instruments. This article provides a high-level overview of these experiments and the methods under development to analyze the resulting data.Comment: 13 pages, 5 figures. Accepted to Journal Of Physics, Conference Series. Presented at 10th International LISA Symposium, May 2014, Gainesville, FL, US

    State space modelling and data analysis exercises in LISA Pathfinder

    Full text link
    LISA Pathfinder is a mission planned by the European Space Agency to test the key technologies that will allow the detection of gravitational waves in space. The instrument on-board, the LISA Technology package, will undergo an exhaustive campaign of calibrations and noise characterisation campaigns in order to fully describe the noise model. Data analysis plays an important role in the mission and for that reason the data analysis team has been developing a toolbox which contains all the functionalities required during operations. In this contribution we give an overview of recent activities, focusing on the improvements in the modelling of the instrument and in the data analysis campaigns performed both with real and simulated data.Comment: Plenary talk presented at the 9th International LISA Symposium, 21-25 May 2012, Pari
    • …
    corecore