128 research outputs found

    Vertical stiffness asymmetries during drop jumping are related to ankle stiffness asymmetries

    Get PDF
    Asymmetry in vertical stiffness has been associated with increased injury incidence and impaired performance. The determinants of vertical stiffness asymmetry have not been previously investigated. Eighteen healthy males performed three unilateral drop jumps during which vertical stiffness and joint stiffness of the ankle and knee were calculated. Reactive strength index was also determined during the jumps using the ratio of flight time to ground contact time. ‘Moderate’ differences in vertical stiffness (t17 = 5.49; P < 0.001), ‘small’ differences in centre of mass displacement (t17 = -2.19; P = 0.043) and ‘trivial’ differences in ankle stiffness (t17 = 2.68; P = 0.016) were observed between stiff and compliant limbs. A model including ankle stiffness and reactive strength index symmetry angles explained 79% of the variance in vertical stiffness asymmetry (R2 = 0.79; P < 0.001). None of the symmetry angles were correlated to jump height or reactive strength index. Results suggest that asymmetries in ankle stiffness may play an important role in modulating vertical stiffness asymmetry in recreationally trained males

    Embracing additive manufacture: implications for foot and ankle orthosis design

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The design of foot and ankle orthoses is currently limited by the methods used to fabricate the devices, particularly in terms of geometric freedom and potential to include innovative new features. Additive manufacturing (AM) technologies, where objects are constructed via a series of sub-millimetre layers of a substrate material, may present the opportunity to overcome these limitations and allow novel devices to be produced that are highly personalised for the individual, both in terms of fit and functionality.</p> <p>Two novel devices, a foot orthosis (FO) designed to include adjustable elements to relieve pressure at the metatarsal heads, and an ankle foot orthosis (AFO) designed to have adjustable stiffness levels in the sagittal plane, were developed and fabricated using AM. The devices were then tested on a healthy participant to determine if the intended biomechanical modes of action were achieved.</p> <p>Results</p> <p>The adjustable, pressure relieving FO was found to be able to significantly reduce pressure under the targeted metatarsal heads. The AFO was shown to have distinct effects on ankle kinematics which could be varied by adjusting the stiffness level of the device.</p> <p>Conclusions</p> <p>The results presented here demonstrate the potential design freedom made available by AM, and suggest that it may allow novel personalised orthotic devices to be produced which are beyond the current state of the art.</p

    The cross on rings performed by an Olympic champion

    Get PDF
    The cross is a key skill in Male Artistic Gymnastics rings routines. However, few researches were found about this skill. There is knowledge about the forces needed to perform the cross, or about muscles activation, separately. The aim of this paper was to accomplish a comprehensive research about the biomechanics of cross on rings, in order to obtain a descriptive model about this skill. Therefore, the currently Olympic champion on rings event volunteered in this research. He performed three crosses with the usual apparatus in his training gym. The measurement methods were combined: One digital video camera, one strain gauge in each cable and surface electromyography of nine right shoulder muscles were used. Statistical analyses were performed by parametric and non parametric tests and descriptive statistics. Symmetry values were calculated for shoulder angles and cables of right and left side. Coefficient of variation of muscle activation and co contraction were verified. Within gymnast variability was calculated using biological coefficient of variation (BCV), discretely for kinematic measures. Low variability values of shoulder angles and cable forces were verified and low values of asymmetry as well. Muscle activation varied according to muscle function, while co-contraction values were different among trials. These results pointed out the characteristics of the cross performed by an elite gymnast. Knowledge about the characteristics of cross can inform coaches, practitioners and clinicians how a successful skill should be presented

    An Investigation of Structure, Flexibility and Function Variables that Discriminate Asymptomatic Foot Types

    Get PDF
    It has been suggested that foot type considers not only foot structure (high, normal, low arch), but also function (overpronation, normal, oversupination) and flexibility (reduced, normal, excessive). Therefore, this study used canonical regression analyses to assess which variables of foot structure, function, and flexibility can accurately discriminate between clinical foot type classifications. The feet of 61 asymptomatic, healthy adults (18–77 years) were classified as cavus (N = 24), rectus (N = 54), or planus (N = 44) using standard clinical measures. Custom jigs assessed foot structure and flexibility. Foot function was assessed using an emed-x plantar pressure measuring device. Canonical regression analyses were applied separately to extract essential structure, flexibility, and function variables. A third canonical regression analysis was performed on the extracted variables to identify a combined model. The initial combined model included 30 extracted variables; however 5 terminal variables (malleolar valgus index, arch height index while sitting, first metatarsophalangeal joint laxity while standing, pressure-time integral and maximum contact area of medial arch) were able to correctly predict 80.7% of foot types. These remaining variables focused on specific foot characteristics (hindfoot alignment, arch height, midfoot mechanics, Windlass mechanism) that could be essential to discriminating foot type

    法政大学図書館一〇〇年史 : 第一編 図書館通史 : 第九章 三キャンパス体制への対応 二、工学部図書館の歩み

    Get PDF
    Lower extremity musculoskeletal injuries are common, complex, and costly problems. Literature supports associations between static foot structure and dynamic foot function, as well as between overuse injury and demographic characteristics. Previous studies failed to provide a comprehensive biomechanical foot characteristics of at-risk military personnel. In this study, foot structure, function, and arch height flexibility (AHF) were objectively measured in 1090 incoming cadets (16.3% female, mean age of 18.5years and BMI of 24.5kg/

    Simulation of gait asymmetry and energy transfer efficiency between unilateral and bilateral amputees

    Get PDF
    Efficient walking or running requires symmetrical gait. Gait symmetry is one of the key factors in efficient human dynamics, kinematics and kinetics. The desire of individuals with a lower-limb amputation to participate in sports has resulted in the development of energy-storing and-returning (ESR) feet. This paper analyses a case study to show the effect of symmetry and asymmetry as well as energy transfer efficiency during periodic jumping between simulated bilateral and unilateral runners. A custom gait analysis system is developed as part of this project to track the motion of the body of a physically active subject during a set of predefined motions. Stance and aerial times are accurately measured using a high speed camera. Gait frequency, the level of symmetry and the non-uniform displacement between left and right foot and their effects on the position of the Centre of Mass (CM) were used as criteria to calculate both peak energies and transformation efficiency. Gait asymmetry and discrepancy of energy transfer efficiency between the intact foot and the ESR are observed. It is concluded that unilateral runners require excessive effort to compensate for lack of symmetry as well as asymmetry in energy transfer, causing fatigue which could be a reason why bilateral amputee runners using ESR feet have a superior advantage over unilateral amputees
    corecore