168 research outputs found
Reflexiones sobre la letrilla que llevaba la Santa Madre Teresa de Jesus
Copia digital. Valladolid : Junta de Castilla y León. Consejería de Cultura y Turismo, 2013[]\p16\s.La il. es un grab. xil. representando a Santa Teresa en p. 3
Complement component 3 (C3) expression in the hippocampus after excitotoxic injury: role of C/EBPβ
[Background] The CCAAT/enhancer-binding protein β (C/EBPβ) is a transcription factor implicated in the control of proliferation, differentiation, and inflammatory processes mainly in adipose tissue and liver; although more recent results have revealed an important role for this transcription factor in the brain. Previous studies from our laboratory indicated that CCAAT/enhancer-binding protein β is implicated in inflammatory process and brain injury, since mice lacking this gene were less susceptible to kainic acid-induced injury. More recently, we have shown that the complement component 3 gene (C3) is a downstream target of CCAAT/enhancer-binding protein β and it could be a mediator of the proinflammatory effects of this transcription factor in neural cells.[Methods] Adult male Wistar rats (8–12 weeks old) were used throughout the study. C/EBPβ+/+ and C/EBPβ–/– mice were generated from heterozygous breeding pairs. Animals were injected or not with kainic acid, brains removed, and brain slices containing the hippocampus analyzed for the expression of both CCAAT/enhancer-binding protein β and C3.[Results] In the present work, we have further extended these studies and show that CCAAT/enhancer-binding protein β and C3 co-express in the CA1 and CA3 regions of the hippocampus after an excitotoxic injury. Studies using CCAAT/enhancer-binding protein β knockout mice demonstrate a marked reduction in C3 expression after kainic acid injection in these animals, suggesting that indeed this protein is regulated by C/EBPβ in the hippocampus in vivo.[Conclusions] Altogether these results suggest that CCAAT/enhancer-binding protein β could regulate brain disorders, in which excitotoxic and inflammatory processes are involved, at least in part through the direct regulation of C3.This work was supported by MINECO, Grant SAF2014-52940-R and partially financed with FEDER funds. CIBERNED is funded by the Instituto de Salud Carlos III. JAM-G was supported by CIBERNED. We acknowledge support of the publication fee by the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI).Peer reviewe
Overlooked post-translational modifications of proteins in Plasmodium falciparum: N- and O-glycosylation - A Review
Human malignant malaria is caused by Plasmodium falciparum and accounts for almost 900,000 deaths per year, the majority of which are children and pregnant women in developing countries. There has been significant effort to understand the biology of P. falciparum and its interactions with the host. However, these studies are hindered because several aspects of parasite biology remain controversial, such as N- and O-glycosylation. This review describes work that has been done to elucidate protein glycosylation in P. falciparum and it focuses on describing biochemical evidence for N- and O-glycosylation. Although there has been significant work in this field, these aspects of parasite biochemistry need to be explored further
Effect of SGLT2 inhibitors on stroke and atrial fibrillation in diabetic kidney disease: Results from the CREDENCE trial and meta-analysis
BACKGROUND AND PURPOSE: Chronic kidney disease with reduced estimated glomerular filtration rate or elevated albuminuria increases risk for ischemic and hemorrhagic stroke. This study assessed the effects of sodium glucose cotransporter 2 inhibitors (SGLT2i) on stroke and atrial fibrillation/flutter (AF/AFL) from CREDENCE (Canagliflozin and Renal Events in Diabetes With Established Nephropathy Clinical Evaluation) and a meta-Analysis of large cardiovascular outcome trials (CVOTs) of SGLT2i in type 2 diabetes mellitus. METHODS: CREDENCE randomized 4401 participants with type 2 diabetes mellitus and chronic kidney disease to canagliflozin or placebo. Post hoc, we estimated effects on fatal or nonfatal stroke, stroke subtypes, and intermediate markers of stroke risk including AF/AFL. Stroke and AF/AFL data from 3 other completed large CVOTs and CREDENCE were pooled using random-effects meta-Analysis. RESULTS: In CREDENCE, 142 participants experienced a stroke during follow-up (10.9/1000 patient-years with canagliflozin, 14.2/1000 patient-years with placebo; hazard ratio [HR], 0.77 [95% CI, 0.55-1.08]). Effects by stroke subtypes were: ischemic (HR, 0.88 [95% CI, 0.61-1.28]; n=111), hemorrhagic (HR, 0.50 [95% CI, 0.19-1.32]; n=18), and undetermined (HR, 0.54 [95% CI, 0.20-1.46]; n=17). There was no clear effect on AF/AFL (HR, 0.76 [95% CI, 0.53-1.10]; n=115). The overall effects in the 4 CVOTs combined were: Total stroke (HRpooled, 0.96 [95% CI, 0.82-1.12]), ischemic stroke (HRpooled, 1.01 [95% CI, 0.89-1.14]), hemorrhagic stroke (HRpooled, 0.50 [95% CI, 0.30-0.83]), undetermined stroke (HRpooled, 0.86 [95% CI, 0.49-1.51]), and AF/AFL (HRpooled, 0.81 [95% CI, 0.71-0.93]). There was evidence that SGLT2i effects on total stroke varied by baseline estimated glomerular filtration rate (P=0.01), with protection in the lowest estimated glomerular filtration rate (45 mL/min/1.73 m2]) subgroup (HRpooled, 0.50 [95% CI, 0.31-0.79]). CONCLUSIONS: Although we found no clear effect of SGLT2i on total stroke in CREDENCE or across trials combined, there was some evidence of benefit in preventing hemorrhagic stroke and AF/AFL, as well as total stroke for those with lowest estimated glomerular filtration rate. Future research should focus on confirming these data and exploring potential mechanisms
A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE
This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model
Snowmass Neutrino Frontier: DUNE Physics Summary
The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of δCP. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter
Snowmass Neutrino Frontier: DUNE Physics Summary
The Deep Underground Neutrino Experiment (DUNE) is a next-generation
long-baseline neutrino oscillation experiment with a primary physics goal of
observing neutrino and antineutrino oscillation patterns to precisely measure
the parameters governing long-baseline neutrino oscillation in a single
experiment, and to test the three-flavor paradigm. DUNE's design has been
developed by a large, international collaboration of scientists and engineers
to have unique capability to measure neutrino oscillation as a function of
energy in a broadband beam, to resolve degeneracy among oscillation parameters,
and to control systematic uncertainty using the exquisite imaging capability of
massive LArTPC far detector modules and an argon-based near detector. DUNE's
neutrino oscillation measurements will unambiguously resolve the neutrino mass
ordering and provide the sensitivity to discover CP violation in neutrinos for
a wide range of possible values of . DUNE is also uniquely
sensitive to electron neutrinos from a galactic supernova burst, and to a broad
range of physics beyond the Standard Model (BSM), including nucleon decays.
DUNE is anticipated to begin collecting physics data with Phase I, an initial
experiment configuration consisting of two far detector modules and a minimal
suite of near detector components, with a 1.2 MW proton beam. To realize its
extensive, world-leading physics potential requires the full scope of DUNE be
completed in Phase II. The three Phase II upgrades are all necessary to achieve
DUNE's physics goals: (1) addition of far detector modules three and four for a
total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power
from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary
muon spectrometer with a magnetized, high-pressure gaseous argon TPC and
calorimeter.Comment: Contribution to Snowmass 202
A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE
This document presents the concept and physics case for a magnetized gaseous
argon-based detector system (ND-GAr) for the Deep Underground Neutrino
Experiment (DUNE) Near Detector. This detector system is required in order for
DUNE to reach its full physics potential in the measurement of CP violation and
in delivering precision measurements of oscillation parameters. In addition to
its critical role in the long-baseline oscillation program, ND-GAr will extend
the overall physics program of DUNE. The LBNF high-intensity proton beam will
provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to
discover new particles and search for new interactions and symmetries beyond
those predicted in the Standard Model.Comment: Contribution to Snowmass 202
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
The Pandora Software Development Kit and algorithm libraries provide
pattern-recognition logic essential to the reconstruction of particle
interactions in liquid argon time projection chamber detectors. Pandora is the
primary event reconstruction software used at ProtoDUNE-SP, a prototype for the
Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at
CERN, is exposed to a charged-particle test beam. This paper gives an overview
of the Pandora reconstruction algorithms and how they have been tailored for
use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam
background particles, the simulated reconstruction and identification
efficiency for triggered test-beam particles is above 80% for the majority of
particle type and beam momentum combinations. Specifically, simulated 1 GeV/
charged pions and protons are correctly reconstructed and identified with
efficiencies of 86.1% and 84.1%, respectively. The efficiencies
measured for test-beam data are shown to be within 5% of those predicted by the
simulation.Comment: 39 pages, 19 figure
- …