61 research outputs found

    Systematic Review The Role of Platelet-Rich Plasma in Arthroscopic Rotator Cuff Repair: A Systematic Review With Quantitative Synthesis

    Get PDF
    Purpose: Despite the theoretic basis and interest in using platelet-rich plasma (PRP) to improve the potential for rotator cuff healing, there remains ongoing controversy regarding its clinical efficacy. The objective of this systematic review was to identify and summarize the available evidence to compare the efficacy of arthroscopic rotator cuff repair in patients with full-thickness rotator cuff tears who were concomitantly treated with PRP. Methods: We searched the Cochrane Central Register of Controlled Trials, Medline, Embase, and PubMed for eligible studies. Two reviewers selected studies for inclusion, assessed methodologic quality, and extracted data. Pooled analyses were performed using a random effects model to arrive at summary estimates of treatment effect with associated 95% confidence intervals. Results: Five studies (2 randomized and 3 nonrandomized with comparative control groups) met the inclusion criteria, with a total of 261 patients. Methodologic quality was uniformly sound as assessed by the Detsky scale and Newcastle-Ottawa Scale. Quantitative synthesis of all 5 studies showed that there was no statistically significant difference in the overall rate of rotator cuff retear between patients treated with PRP and those treated without PRP (risk ratio, 0.77; 95% confidence interval, 0.48 to 1.23). There were also no differences in the pooled Constant score; Simple Shoulder Test score; American Shoulder and Elbow Surgeons score; University of California, Los Angeles shoulder score; or Single Assessment Numeric Evaluation score. Conclusions: PRP does not have an effect on overall retear rates or shoulder-specific outcomes after arthroscopic rotator cuff repair. Additional well-designed randomized trials are needed to corroborate these findings. Level of Evidence: Level III, systematic review of Level I, II, and III studies

    Granulocytic sarcoma (chloroma) of the oral cavity: Report of a case and literature review

    Get PDF
    SummaryA case of granulocytic sarcoma (chloroma) of the palatal mucosa is reported. Granulocytic sarcomas are composed of a localized collection of immature myeloid cells and are considered to be specific lesions of AML or the onset of a blast crisis in chronic myelogenous leukemia (CML). Localization in the oral cavity is rare. A review of the literature showed only thirty-six cases of granulocytic sarcoma in the oral cavity. In this paper we present patient’s data and an overview of the literature

    Search for Neutral Q-balls in Super-Kamiokande II

    Full text link
    A search for Q-balls induced groups of successive contained events has been carried out in Super-Kamiokande II with 541.7 days of live time. Neutral Q-balls would emit pions when colliding with nuclei, generating a signal of successive contained pion events along a track. No candidate for successive contained event groups has been found in Super-Kamiokande II, so upper limits on the possible flux of such Q-balls have been obtained.Comment: 5 pages, 5 figures, Submitted to Phys. Lett.

    Search for astrophysical electron antineutrinos in Super-Kamiokande with 0.01wt% gadolinium-loaded water

    Get PDF
    We report the first search result for the flux of astrophysical electron antineutrinos for energies O(10) MeV in the gadolinium-loaded Super-Kamiokande (SK) detector. In June 2020, gadolinium was introduced to the ultra-pure water of the SK detector in order to detect neutrons more efficiently. In this new experimental phase, SK-Gd, we can search for electron antineutrinos via inverse beta decay with efficient background rejection and higher signal efficiency thanks to the high efficiency of the neutron tagging technique. In this paper, we report the result for the initial stage of SK-Gd with a 22.5×55222.5\times552 ktonday\rm kton\cdot day exposure at 0.01% Gd mass concentration. No significant excess over the expected background in the observed events is found for the neutrino energies below 31.3 MeV. Thus, the flux upper limits are placed at the 90% confidence level. The limits and sensitivities are already comparable with the previous SK result with pure-water (22.5×2970ktonday22.5 \times 2970 \rm kton\cdot day) owing to the enhanced neutron tagging

    Performance of SK-Gd’s upgraded real-time supernova monitoring system

    Get PDF
    Among multimessenger observations of the next Galactic core-collapse supernova, Super-Kamiokande (SK) plays a critical role in detecting the emitted supernova neutrinos, determining the direction to the supernova (SN), and notifying the astronomical community of these observations in advance of the optical signal. In 2022, SK has increased the gadolinium dissolved in its water target (SK-Gd) and has achieved a Gd concentration of 0.033%, resulting in enhanced neutron detection capability, which in turn enables more accurate determination of the supernova direction. Accordingly, SK-Gd's real-time supernova monitoring system has been upgraded. SK_SN Notice, a warning system that works together with this monitoring system, was released on 2021 December 13, and is available through GCN Notices. When the monitoring system detects an SN-like burst of events, SK_SN Notice will automatically distribute an alarm with the reconstructed direction to the supernova candidate within a few minutes. In this paper, we present a systematic study of SK-Gd's response to a simulated Galactic SN. Assuming a supernova situated at 10 kpc, neutrino fluxes from six supernova models are used to characterize SK-Gd's pointing accuracy using the same tools as the online monitoring system. The pointing accuracy is found to vary from 3° to 7° depending on the models. However, if the supernova is closer than 10 kpc, SK_SN Notice can issue an alarm with three-degree accuracy, which will benefit follow-up observations by optical telescopes with large fields of view

    Measurement of coherent π+π^{+} production in low energy neutrino-Carbon scattering

    Get PDF
    We report the first measurement of the flux-averaged cross section for charged current coherent π+\pi^{+} production on carbon for neutrino energies less than 1.5 GeV to a restricted final state phase space region in the T2K near detector, ND280. Comparisons are made with predictions from the Rein-Sehgal coherent production model and the model by Alvarez-Ruso {\it et al.}, the latter representing the first implementation of an instance of the new class of microscopic coherent models in a neutrino interaction Monte Carlo event generator. This results contradicts the null results reported by K2K and SciBooNE in a similar neutrino energy region

    Performance of SK-Gd's upgraded real-time supernova monitoring system

    Get PDF
    Among multi-messenger observations of the next galactic core-collapse supernova, Super-Kamiokande (SK) plays a critical role in detecting the emitted supernova neutrinos, determining the direction to the supernova (SN), and notifying the astronomical community of these observations in advance of the optical signal. On 2022, SK has increased the gadolinium dissolved in its water target (SK-Gd) and has achieved a Gd concentration of 0.033%, resulting in enhanced neutron detection capability, which in turn enables more accurate determination of the supernova direction. Accordingly, SK-Gd's real-time supernova monitoring system (Abe te al. 2016b) has been upgraded. SK_SN Notice, a warning system that works together with this monitoring system, was released on December 13, 2021, and is available through GCN Notices (Barthelmy et al. 2000). When the monitoring system detects an SN-like burst of events, SK_SN Notice will automatically distribute an alarm with the reconstructed direction to the supernova candidate within a few minutes. In this paper, we present a systematic study of SK-Gd's response to a simulated galactic SN. Assuming a supernova situated at 10 kpc, neutrino fluxes from six supernova models are used to characterize SK-Gd's pointing accuracy using the same tools as the online monitoring system. The pointing accuracy is found to vary from 3-7∘ depending on the models. However, if the supernova is closer than 10 kpc, SK_SN Notice can issue an alarm with three-degree accuracy, which will benefit follow-up observations by optical telescopes with large fields of view

    Measurements of the charge ratio and polarization of cosmic-ray muons with the Super-Kamiokande detector

    Get PDF
    We present the results of the charge ratio (R) and polarization (Pμ0) measurements using the decay electron events collected from 2008 September to 2022 June by the Super-Kamiokande detector. Because of its underground location and long operation, we performed high precision measurements by accumulating cosmic-ray muons. We measured the muon charge ratio to be R=1.32±0.02 (stat.+syst.) at EμcosθZenith=0.7+0.3−0.2 TeV, where Eμ is the muon energy and θZenith is the zenith angle of incoming cosmic-ray muons. This result is consistent with the Honda flux model while this suggests a tension with the πK model of 1.9σ. We also measured the muon polarization at the production location to be Pμ0=0.52±0.02 (stat.+syst.) at the muon momentum of 0.9+0.6−0.1 TeV/c at the surface of the mountain; this also suggests a tension with the Honda flux model of 1.5σ. This is the most precise measurement ever to experimentally determine the cosmic-ray muon polarization near 1 TeV/c. These measurement results are useful to improve the atmospheric neutrino simulations

    The Addition of a Pericapsular Nerve Group Block for Postoperative Pain Control Does Not Result in Less Narcotic Use After Hip Arthroscopy: A Systematic Review

    No full text
    Purpose: To perform a systematic review of clinical studies evaluating the pericapsular nerve group (PENG) block in patients undergoing hip arthroscopy. Methods: A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify comparative studies of patients undergoing the PENG block before hip arthroscopy. The search phrase used was hip arthroscopy pericapsular nerve block. Patients were evaluated based on analgesic consumption, time to discharge from the postanesthesia care unit (PACU), and pain scores (Numeric Rating Scale and visual analog scale). The Modified Coleman Methodology Score was used to evaluate study methodology quality. Results: Five studies (2 Level I, 3 Level III) met inclusion criteria. The 5 studies included the following comparison groups: 0.9% normal saline injection, general anesthesia alone, and general anesthesia with intraoperative pericapsular bupivacaine injection. The 2 randomized controlled trials included in this review reported no significant difference between groups regarding opioid consumption. One of these did not find any statistically significant differences in their secondary outcomes either, including patient satisfaction with analgesia, opioid-related adverse events, or persistent opioid use at 1 week. However, the other 3 studies found significantly lower opioid consumption in patients receiving the PENG block versus the control group intraoperatively, in the PACU, and/or postoperatively. Four studies reported significantly lower pain levels in the PENG block group compared with the control groups, measured differently in each study: 24 hours postoperatively, initial pain score in the PACU, mean score in the PACU, and highest score in the PACU. None of the studies found significantly worse outcomes in the PENG block group compared to the comparison group. Conclusions: Systematic review of randomized controlled trials shows that patients undergoing hip arthroscopy who receive a PENG block do not consume fewer opioids for postoperative pain control than patients who do not receive the block. Level of Evidence: Level III, systematic review of Level I-III studies
    corecore