31 research outputs found

    Energy Harvesting from Ultra-low-Frequency Vibrations Through a Quasi-zero Stiffness Electromagnetic Energy Harvester

    Get PDF
    Purpose: To scavenge vibrational energy from ultra-low frequency vibrations with low excitation levels, this paper presents a novel quasi-zero stiffness electromagnetic energy harvester (QZS-EMEH) by exploiting a rolling magnet system. Methods: By calculating the nonlinear restoring force exerted on the moving magnet, the parameter region that results in conditions of quasi-zero stiffness is determined, and a theoretical model of the QZS-EMEH is established. Based on the method of harmonic balance, the analytical solution of the QZS-EMEH is derived, and the influence of system parameters on the response characteristics and energy harvesting performance is discussed. Results: Numerical and theoretical results indicate that the QZS-EMEH can efficiently harness energy in a wide frequency range under low-level excitations. Furthermore, the nonlinear dynamics of the QZS-EMEH are investigated based on the bifurcation diagram, phase orbit, Poincaré map, and basin of attraction, demonstrating that appropriate initial conditions can lead to the high-energy orbit oscillation. Conclusions: Finally, realistic ambient vibration accelerations from a bus and a human body are applied to excite the QZS-EMEH, and the results illustrate that the QZS-EMEH can generate considerable electrical output power and has excellent application prospects.</p

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).

    Get PDF
    Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≄1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≀6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    Possible strategies for performance enhancement of asymmetric potential bistable energy harvesters by orbit jumps

    No full text
    Due to the merits of broadband response and high sensitivity, bistable oscillators have garnered a great deal of attention in the field of vibrational energy harvesting. However, it is difficult to achieve a bistable energy harvester (BEH) with a perfectly symmetric potential due to the imperfections in materials and structures, and this will greatly influence the output performance. Therefore, this paper focuses on the possible strategies for performance enhancement of asymmetric potential BEHs. Numerical analysis based on voltage response, bifurcation diagram and basin of attraction demonstrates that the appearance of asymmetric potentials in BEHs has a negative effect on the output performance. Average output power and voltage response under different conditions indicate that proper initial conditions and external disturbance could enable the BEHs to achieve high-energy orbit oscillation. Additionally, it is proved that the BEHs can jump from the low-energy orbit to the high-energy orbit to generate more electrical power by changing the phase of excitation signal and external load resistance. By properly selecting the performance enhancement strategies proposed in this paper, the output power of the asymmetric potential BEHs could be improved in practical application
    corecore