155 research outputs found

    The use of bio-electrical impedance analysis (BIA) to guide fluid management, resuscitation and deresuscitation in critically ill patients : a bench-to-bedside review

    Get PDF
    The impact of a positive fluid balance on morbidity and mortality has been well established. However, little is known about how to monitor fluid status and fluid overload. This narrative review summarises the recent literature and discusses the different parameters related to bio-electrical impedance analysis (BIA) and how they might be used to guide fluid management in critically ill patients. Definitions are listed for the different parameters that can be obtained with BIA; these include among others total body water (TBW), intracellular water (ICW), extracellular water (ECW), ECW/ICW ratio and volume excess (VE). BIA allows calculation of body composition and volumes by means of a current going through the body considered as a cylinder. Reproducible measurements can be obtained with tetrapolar electrodes with two current and two detection electrodes placed on hands and feet. Modern devices also apply multiple frequencies, further improving the accuracy and reproducibility of the results. Some pitfalls and conditions are discussed that need to be taken into account for correct BIA interpretation. Although BIA is a simple, noninvasive, rapid, portable, reproducible, and convenient method of measuring body composition and fluid distribution with fewer physical demands than other techniques, it is still unclear whether it is sufficiently accurate for clinical use in critically ill patients. However, the potential clinical applications are numerous. An overview regarding the use of BIA parameters in critically ill patients is given, based on the available literature. BIA seems a promising tool if performed correctly. It is non-invasive and relatively inexpensive and can be performed at bedside, and it does not expose to ionising radiation. Modern devices have very limited between-observer variations, but BIA parameters are population-specific and one must be aware of clinical situations that may interfere with the measurement such as visible oedema, nutritional status, or fluid and salt administration. BIA can help guide fluid management, resuscitation and de-resuscitation. The latter is especially important in patients not progressing spontaneously from the Ebb to the Flow phase of shock. More research is needed in critically ill patients before widespread use of BIA can be suggested in this patient population.The impact of a positive fluid balance on morbidity and mortality has been well established. However, little is known about how to monitor fluid status and fluid overload. This narrative review summarises the recent literature and discusses the different parameters related to bio-electrical impedance analysis (BIA) and how they might be used to guide fluid management in critically ill patients. Definitions are listed for the different parameters that can be obtained with BIA; these include among others total body water (TBW), intracellular water (ICW), extracellular water (ECW), ECW/ICW ratio and volume excess (VE). BIA allows calculation of body composition and volumes by means of a current going through the body considered as a cylinder. Reproducible measurements can be obtained with tetrapolar electrodes with two current and two detection electrodes placed on hands and feet. Modern devices also apply multiple frequencies, further improving the accuracy and reproducibility of the results. Some pitfalls and conditions are discussed that need to be taken into account for correct BIA interpretation. Although BIA is a simple, noninvasive, rapid, portable, reproducible, and convenient method of measuring body composition and fluid distribution with fewer physical demands than other techniques, it is still unclear whether it is sufficiently accurate for clinical use in critically ill patients. However, the potential clinical applications are numerous. An overview regarding the use of BIA parameters in critically ill patients is given, based on the available literature. BIA seems a promising tool if performed correctly. It is non-invasive and relatively inexpensive and can be performed at bedside, and it does not expose to ionising radiation. Modern devices have very limited between-observer variations, but BIA parameters are population-specific and one must be aware of clinical situations that may interfere with the measurement such as visible oedema, nutritional status, or fluid and salt administration. BIA can help guide fluid management, resuscitation and de-resuscitation. The latter is especially important in patients not progressing spontaneously from the Ebb to the Flow phase of shock. More research is needed in critically ill patients before widespread use of BIA can be suggested in this patient population

    Relationship between Abdominal Pressure, Pulmonary Compliance, and Cardiac Preload in a Porcine Model

    Get PDF
    Rationale. Elevated intra-abdominal pressure (IAP) may compromise respiratory and cardiovascular function by abdomino-thoracic pressure transmission. We aimed (1) to study the effects of elevated IAP on pleural pressure, (2) to understand the implications for lung and chest wall compliances and (3) to determine whether volumetric filling parameters may be more accurate than classical pressure-based filling pressures for preload assessment in the setting of elevated IAP. Methods. In eleven pigs, IAP was increased stepwise from 6 to 30 mmHg. Hemodynamic, esophageal, and pulmonary pressures were recorded. Results. 17% (end-expiratory) to 62% (end-inspiratory) of elevated IAP was transmitted to the thoracic compartment. Respiratory system compliance decreased significantly with elevated IAP and chest wall compliance decreased. Central venous and pulmonary wedge pressure increased with increasing IAP and correlated inversely (r = −0.31) with stroke index (SI). Global end-diastolic volume index was unaffected by IAP and correlated best with SI (r = 0.52). Conclusions. Increased IAP is transferred to the thoracic compartment and results in a decreased respiratory system compliance due to decreased chest wall compliance. Volumetric filling parameters and transmural filling pressures are clearly superior to classical cardiac filling pressures in the assessment of cardiac preload during elevated IAP

    Understanding farm generational renewal and its influencing factors in Europe

    Get PDF
    Understanding the complex process of generational renewal (GR) in agriculture is essential for supporting the continuation of farming. This paper demonstrates how multiple factors, simultaneously and through their mutual interactions, influence GR and related individual decision-making processes. Results originated from 155 in-depth interviews performed on 85 farms in eleven European regions, and were triangulated with the literature. Our analysis, combining inductive and deductive approaches, revealed three conceptual phases (successor identity formation, farm succession process, and farm development) and fourteen factors important to understand GR. We elaborate how these factors interact, hence exert their impact on (one of) the phases in a complex and variable way. Implications highlight potential pitfalls and opportunities for attracting people into agriculture. Although policy-makers should be aware of their limited ability to affect GR by targeting the first phase, we propose some ideas that would complement current existing measures acting on the third phase

    Methodologies for in vitro and in vivo evaluation of efficacy of antifungal and antibiofilm agents and surface coatings against fungal biofilms

    Get PDF
    KT acknowledges receipt of a mandate of Industrial Research Fund (IOFm/05/022). JB acknowledges funding from the European Research Council Advanced Award 3400867/RAPLODAPT and the Israel Science Foundation grant # 314/13 (www.isf.il). NG acknowledges the Wellcome Trust and MRC for funding. CD acknowledges funding from the Agence Nationale de Recherche (ANR-10-LABX-62-IBEID). CJN acknowledges funding from the National Institutes of Health R35GM124594 and R21AI125801. AW is supported by the Wellcome Trust Strategic Award (grant 097377), the MRC Centre for Medical Mycology (grant MR/N006364/1) at the University of Aberdeen MaCA: outside this study MaCA has received personal speaker’s honoraria the past five years from Astellas, Basilea, Gilead, MSD, Pfizer, T2Candida, and Novartis. She has received research grants and contract work paid to the Statens Serum Institute from Astellas, Basilea, Gilead, MSD, NovaBiotics, Pfizer, T2Biosystems, F2G, Cidara, and Amplyx. CAM acknowledges the Wellcome Trust and the MRC MR/N006364/1. PVD, TC and KT acknowledge the FWO research community: Biology and ecology of bacterial and fungal biofilms in humans (FWO WO.009.16N). AAB acknowledges the Deutsche Forschungsgemeinschaft – CRC FungiNet.Peer reviewedPublisher PD

    Incidence and outcome of invasive candidiasis in intensive care units (ICUs) in Europe: results of the EUCANDICU project

    Get PDF
    BACKGROUND: The objective of this study was to assess the cumulative incidence of invasive candidiasis (IC) in intensive care units (ICUs) in Europe. METHODS: A multinational, multicenter, retrospective study was conducted in 23 ICUs in 9 European countries, representing the first phase of the candidemia/intra-abdominal candidiasis in European ICU project (EUCANDICU). RESULTS: During the study period, 570 episodes of ICU-acquired IC were observed, with a cumulative incidence of 7.07 episodes per 1000 ICU admissions, with important between-center variability. Separated, non-mutually exclusive cumulative incidences of candidemia and IAC were 5.52 and 1.84 episodes per 1000 ICU admissions, respectively. Crude 30-day mortality was 42%. Age (odds ratio [OR] 1.04 per year, 95% CI 1.02-1.06, p < 0.001), severe hepatic failure (OR 3.25, 95% 1.31-8.08, p 0.011), SOFA score at the onset of IC (OR 1.11 per point, 95% CI 1.04-1.17, p 0.001), and septic shock (OR 2.12, 95% CI 1.24-3.63, p 0.006) were associated with increased 30-day mortality in a secondary, exploratory analysis. CONCLUSIONS: The cumulative incidence of IC in 23 European ICUs was 7.07 episodes per 1000 ICU admissions. Future in-depth analyses will allow explaining part of the observed between-center variability, with the ultimate aim of helping to improve local infection control and antifungal stewardship projects and interventions
    corecore