465 research outputs found

    Lesional-targeting of neuroprotection to the inflammatory penumbra in experimental multiple sclerosis

    Get PDF
    The authors would like to thank the support of the National Multiple Sclerosis Society (USA) and the Multiple Sclerosis Society of Great Britain and Northern Ireland

    Using haloperidol as an anti-emetic in palliative care: informing practice through evidence from cancer treatment and post-operative contexts

    Get PDF
    YesNausea and vomiting are common symptoms in palliative care. Haloperidol is often used as an antiemetic in this context, although direct evidence supporting this practice is limited. To evaluate the efficacy and clinical use of haloperidol as an antiemetic in nonpalliative care contexts to inform practice, the authors conducted a rapid review of (i) published evidence to supplement existing systematic reviews, and (ii) practical aspects affecting the use of haloperidol including formulations and doses that are commonly available internationally. In nausea and vomiting related to cancer treatment, haloperidol was superior to control in two small studies. In postoperative nausea and vomiting (PONV), two randomized controlledtrials found treatment with haloperidol comparable to ondansetron. In palliative care, an observational study found a complete response rate of 24% with haloperidol (one in four patients) which would be consistent with a number needed to treat (NNT) of 3 to 5 derived from PONV. There remains insufficient direct evidence to definitively support the use of haloperidol for the management of nausea and vomiting in palliative care. However, generalizing evidence from other clinical contexts may have some validity

    A high-throughput de novo sequencing approach for shotgun proteomics using high-resolution tandem mass spectrometry

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>High-resolution tandem mass spectra can now be readily acquired with hybrid instruments, such as LTQ-Orbitrap and LTQ-FT, in high-throughput shotgun proteomics workflows. The improved spectral quality enables more accurate <it>de novo </it>sequencing for identification of post-translational modifications and amino acid polymorphisms.</p> <p>Results</p> <p>In this study, a new <it>de novo </it>sequencing algorithm, called Vonode, has been developed specifically for analysis of such high-resolution tandem mass spectra. To fully exploit the high mass accuracy of these spectra, a unique scoring system is proposed to evaluate sequence tags based primarily on mass accuracy information of fragment ions. Consensus sequence tags were inferred for 11,422 spectra with an average peptide length of 5.5 residues from a total of 40,297 input spectra acquired in a 24-hour proteomics measurement of <it>Rhodopseudomonas palustris</it>. The accuracy of inferred consensus sequence tags was 84%. According to our comparison, the performance of Vonode was shown to be superior to the PepNovo v2.0 algorithm, in terms of the number of <it>de novo </it>sequenced spectra and the sequencing accuracy.</p> <p>Conclusions</p> <p>Here, we improved <it>de novo </it>sequencing performance by developing a new algorithm specifically for high-resolution tandem mass spectral data. The Vonode algorithm is freely available for download at <url>http://compbio.ornl.gov/Vonode</url>.</p

    Study of the reaction e^{+}e^{-} -->J/psi\pi^{+}\pi^{-} via initial-state radiation at BaBar

    Get PDF
    We study the process e+eJ/ψπ+πe^+e^-\to J/\psi\pi^{+}\pi^{-} with initial-state-radiation events produced at the PEP-II asymmetric-energy collider. The data were recorded with the BaBar detector at center-of-mass energies 10.58 and 10.54 GeV, and correspond to an integrated luminosity of 454 fb1\mathrm{fb^{-1}}. We investigate the J/ψπ+πJ/\psi \pi^{+}\pi^{-} mass distribution in the region from 3.5 to 5.5 GeV/c2\mathrm{GeV/c^{2}}. Below 3.7 GeV/c2\mathrm{GeV/c^{2}} the ψ(2S)\psi(2S) signal dominates, and above 4 GeV/c2\mathrm{GeV/c^{2}} there is a significant peak due to the Y(4260). A fit to the data in the range 3.74 -- 5.50 GeV/c2\mathrm{GeV/c^{2}} yields a mass value 4244±54244 \pm 5 (stat) ±4 \pm 4 (syst)MeV/c2\mathrm{MeV/c^{2}} and a width value 11415+16114 ^{+16}_{-15} (stat)±7 \pm 7(syst)MeV\mathrm{MeV} for this state. We do not confirm the report from the Belle collaboration of a broad structure at 4.01 GeV/c2\mathrm{GeV/c^{2}}. In addition, we investigate the π+π\pi^{+}\pi^{-} system which results from Y(4260) decay

    Techniques for accurate protein identification in shotgun proteomic studies of human, mouse, bovine, and chicken lenses

    Get PDF
    Analysis of shotgun proteomics datasets requires techniques to distinguish correct peptide identifications from incorrect identifications, such as linear discriminant functions and target/decoy protein databases. We report an efficient, flexible proteomic analysis workflow pipeline that implements these techniques to control both peptide and protein false discovery rates. We demonstrate its performance by analyzing two-dimensional liquid chromatography separations of lens proteins from human, mouse, bovine, and chicken lenses. We compared the use of International Protein Index databases to UniProt databases and no-enzyme SEQUEST searches to tryptic searches. Sequences present in the International Protein Index databases allowed detection of several novel crystallins. An alternate start codon isoform of βA4 was found in human lens. The minor crystallin γN was detected for the first time in bovine and chicken lenses. Chicken γS was identified and is the first member of the γ-crystallin family observed in avian lenses

    Direct Regulation of Striated Muscle Myosins by Nitric Oxide and Endogenous Nitrosothiols

    Get PDF
    , both through activation of guanylyl cyclase and through modification of cysteines in proteins to yield S-nitrosothiols. While NO affects the contractile apparatus directly, the identities of the target myofibrillar proteins remain unknown. Here we report that nitrogen oxides directly regulate striated muscle myosins..These data show that nitrosylation signaling acts as a molecular “gear shift” for myosin—an altogether novel mechanism by which striated muscle and cellular biomechanics may be regulated

    PCR colorimetric dot-blot assay and clinical pretest probability for diagnosis of Pulmonary Tuberculosis in Smear-Negative patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Smear-negative pulmonary tuberculosis (SNPTB) accounts for 30% of Pulmonary Tuberculosis (PTB) cases reported annually in developing nations. Polymerase chain reaction (PCR) may provide an alternative for the rapid detection of <it>Mycobacterium tuberculosis </it>(MTB); however little data are available regarding the clinical utility of PCR in SNPTB, in a setting with a high burden of TB/HIV co-infection.</p> <p>Methods</p> <p>To evaluate the performance of the PCR dot-blot in parallel with pretest probability (Clinical Suspicion) in patients suspected of having SNPTB, a prospective study of 213 individuals with clinical and radiological suspicion of SNPTB was carried out from May 2003 to May 2004, in a TB/HIV reference hospital. Respiratory specialists estimated the pretest probability of active disease into high, intermediate, low categories. Expectorated sputum was examined by direct microscopy (Ziehl-Neelsen staining), culture (Lowenstein Jensen) and PCR dot-blot. Gold standard was based on culture positivity combined with the clinical definition of PTB.</p> <p>Results</p> <p>In smear-negative and HIV subjects, active PTB was diagnosed in 28.4% (43/151) and 42.2% (19/45), respectively. In the high, intermediate and low pretest probability categories active PTB was diagnosed in 67.4% (31/46), 24% (6/25), 7.5% (6/80), respectively. PCR had sensitivity of 65% (CI 95%: 50%–78%) and specificity of 83% (CI 95%: 75%–89%). There was no difference in the sensitivity of PCR in relation to HIV status. PCR sensitivity and specificity among non-previously TB treated and those treated in the past were, respectively: 69%, 43%, 85% and 80%. The high pretest probability, when used as a diagnostic test, had sensitivity of 72% (CI 95%:57%–84%) and specificity of 86% (CI 95%:78%–92%). Using the PCR dot-blot in parallel with high pretest probability as a diagnostic test, sensitivity, specificity, positive and negative predictive values were: 90%, 71%, 75%, and 88%, respectively. Among non-previously TB treated and HIV subjects, this approach had sensitivity, specificity, positive and negative predictive values of 91%, 79%, 81%, 90%, and 90%, 65%, 72%, 88%, respectively.</p> <p>Conclusion</p> <p>PCR dot-blot associated with a high clinical suspicion may provide an important contribution to the diagnosis of SNPTB mainly in patients that have not been previously treated attended at a TB/HIV reference hospital.</p

    Cost-effectiveness analysis of PCR for the rapid diagnosis of pulmonary tuberculosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Tuberculosis is one of the most prominent health problems in the world, causing 1.75 million deaths each year. Rapid clinical diagnosis is important in patients who have co-morbidities such as Human Immunodeficiency Virus (HIV) infection. Direct microscopy has low sensitivity and culture takes 3 to 6 weeks <abbrgrp><abbr bid="B1">1</abbr><abbr bid="B2">2</abbr><abbr bid="B3">3</abbr></abbrgrp>. Therefore, new tools for TB diagnosis are necessary, especially in health settings with a high prevalence of HIV/TB co-infection.</p> <p>Methods</p> <p>In a public reference TB/HIV hospital in Brazil, we compared the cost-effectiveness of diagnostic strategies for diagnosis of pulmonary TB: Acid fast bacilli smear microscopy by Ziehl-Neelsen staining (AFB smear) plus culture and AFB smear plus colorimetric test (PCR dot-blot).</p> <p>From May 2003 to May 2004, sputum was collected consecutively from PTB suspects attending the Parthenon Reference Hospital. Sputum samples were examined by AFB smear, culture, and PCR dot-blot. The gold standard was a positive culture combined with the definition of clinical PTB. Cost analysis included health services and patient costs.</p> <p>Results</p> <p>The AFB smear plus PCR dot-blot require the lowest laboratory investment for equipment (US20,000).Thetotalscreeningcostsare3.8timesforAFBsmearpluscultureversusforAFBsmearplusPCRdotblotcosts(US 20,000). The total screening costs are 3.8 times for AFB smear plus culture versus for AFB smear plus PCR dot blot costs (US 5,635,760 versus US1,498,660).CostspercorrectlydiagnosedcasewereUS 1,498, 660). Costs per correctly diagnosed case were US 50,773 and US13,749forAFBsmearpluscultureandAFBsmearplusPCRdotblot,respectively.AFBsmearplusPCRdotblotwasmorecosteffectivethanAFBsmearplusculture,whenthecostoftreatingallcorrectlydiagnosedcaseswasconsidered.Thecostofreturningpatients,whicharenottreatedduetoanegativeresult,tothehealthservice,washigherinAFBsmearplusculturethanforAFBsmearplusPCRdotblot,US 13,749 for AFB smear plus culture and AFB smear plus PCR dot-blot, respectively. AFB smear plus PCR dot-blot was more cost-effective than AFB smear plus culture, when the cost of treating all correctly diagnosed cases was considered. The cost of returning patients, which are not treated due to a negative result, to the health service, was higher in AFB smear plus culture than for AFB smear plus PCR dot-blot, US 374,778,045 and US$ 110,849,055, respectively.</p> <p>Conclusion</p> <p>AFB smear associated with PCR dot-blot associated has the potential to be a cost-effective tool in the fight against PTB for patients attended in the TB/HIV reference hospital.</p
    corecore