479 research outputs found

    The thienopyridine A-769662 and benzimidazole 991 inhibit human TASK-3 potassium channels in an AMPK-independent manner

    Get PDF
    Heteromeric Tandem pore domain Acid Sensitive (TASK)-1/3 channels are critical to oxygen-sensing by carotid body type 1 cells, where hypoxia-induced inhibition of TASK-3 and/or TASK-1/3 potassium currents leads to voltage-gated calcium entry, exocytotic transmitter release and increases in carotid body afferent input responses that initiate corrective changes in breathing patterns. It was proposed that, in response to hypoxia, the AMP–activated protein kinase (AMPK) might directly phosphorylate and inhibit TASK channels, in particular TASK–3, but studies on rat type I cells questioned this view. However, sequence alignment identified a putative AMPK recognition motif in human (h) TASK-3, but not hTASK–1, with Ser55 representing a potential phosphorylation site. We therefore studied the effects of five different AMPK activators on recombinant hTASK–3 potassium channels expressed in human embryonic kidney (HEK)–293 cells. Two structurally unrelated AMPK activators, the thienopyridine A–769662 (100–500 µM) and the benzimidazole 991 (3–30 µM) inhibited hTASK–3 currents in a concentration–dependent manner, while the 4-azabenzimidazole MK–8722 (3–30 µM) partially inhibited hTASK–3 at concentrations above those required for maximal AMPK activation. By contrast, the 4-azabenzimidazole, BI-9774 (10–100 µM; a closely related analogue of MK8722) and the pro-drug AICA-riboside (1 mM; metabolised to ZMP, an AMP-mimetic) had no significant effect on hTASK–3 currents at concentrations sufficient to maximally activate AMPK. Importantly, A–769662 (300 µM) also inhibited hTASK–3 channel currents in HEK–293 cells that stably over-expressed an AMPK–β1 subunit mutant (S108A) that renders AMPK insensitive to activators that bind to the Allosteric Drug and Metabolite site, such as A–769662. We therefore identify A–769662 and 991 as novel hTASK–3 channel inhibitors and provide conclusive evidence that AMPK does not regulate hTASK–3 channel current

    Validation of the Kinetik Blood Pressure Monitor-Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices

    Get PDF
    The aim of this study was to assess the blood pressure (BP) measurement accuracy of the Kinetik Blood Pressure Monitor—Series 1 (BPM-1) for use in home or clinical settings according to the 2002 European Society of Hypertension International Protocol (ESH-IP). Forty-two participants were recruited to fulfil the required number of systolic and diastolic BP measurements according to the ESH-IP. Nine sequential same-arm BP readings were measured and analysed for each participant using the test device and observer mercury standard readings according to the 2002 ESH-IP. Forty one participants were used to obtain 33 sets of systolic and diastolic BP readings and were included in the analysis. Mean difference between the device measurements and the observer (mercury standard) measurements was 1.1 ± 7.2/1.1 ± 6.8 mmHg (mean ± standard deviation; systolic/diastolic). The number of systolic BP differences between the test and observer measurements that fell within 5, 10 and 15 mmHg was 65, 86 and 92. For diastolic readings, the number of test—observer measurement differences within 5, 10 and 15 mmHg was 77, 91 and 94. The number of participants with at least two out of three differences within 5 mmHg was 28 for systolic and 40 for diastolic BP readings. Three participants had no differences between the test and observer measurements within 5 mmHg in both the systolic and diastolic measurement categories. The Kinetik BPM-1 device fulfilled the requirements of the ESH-IP validation procedure and can be recommended for clinical use and self-measurement within the home

    Validation of the Kinetik Blood Pressure Monitor—Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices

    Get PDF
    The aim of this study was to assess the blood pressure (BP) measurement accuracy of the Kinetik Blood Pressure Monitor—Series 1 (BPM-1) for use in home or clinical settings according to the 2002 European Society of Hypertension International Protocol (ESH-IP). Forty-two participants were recruited to fulfil the required number of systolic and diastolic BP measurements according to the ESH-IP. Nine sequential same-arm BP readings were measured and analysed for each participant using the test device and observer mercury standard readings according to the 2002 ESH-IP. Forty one participants were used to obtain 33 sets of systolic and diastolic BP readings and were included in the analysis. Mean difference between the device measurements and the observer (mercury standard) measurements was 1.1 ± 7.2/1.1 ± 6.8 mmHg (mean ± standard deviation; systolic/diastolic). The number of systolic BP differences between the test and observer measurements that fell within 5, 10 and 15 mmHg was 65, 86 and 92. For diastolic readings, the number of test—observer measurement differences within 5, 10 and 15 mmHg was 77, 91 and 94. The number of participants with at least two out of three differences within 5 mmHg was 28 for systolic and 40 for diastolic BP readings. Three participants had no differences between the test and observer measurements within 5 mmHg in both the systolic and diastolic measurement categories. The Kinetik BPM-1 device fulfilled the requirements of the ESH-IP validation procedure and can be recommended for clinical use and self-measurement within the home

    VennPlex--a novel Venn diagram program for comparing and visualizing datasets with differentially regulated datapoints.

    Get PDF
    With the development of increasingly large and complex genomic and proteomic data sets, an enhancement in the complexity of available Venn diagram analytical programs is becoming increasingly important. Current freely available Venn diagram programs often fail to represent extra complexity among datasets, such as regulation pattern differences between different groups. Here we describe the development of VennPlex, a program that illustrates the often diverse numerical interactions among multiple, high-complexity datasets, using up to four data sets. VennPlex includes versatile output features, where grouped data points in specific regions can be easily exported into a spreadsheet. This program is able to facilitate the analysis of two to four gene sets and their corresponding expression values in a user-friendly manner. To demonstrate its unique experimental utility we applied VennPlex to a complex paradigm, i.e. a comparison of the effect of multiple oxygen tension environments (1–20% ambient oxygen) upon gene transcription of primary rat astrocytes. VennPlex accurately dissects complex data sets reliably into easily identifiable groups for straightforward analysis and data output. This program, which is an improvement over currently available Venn diagram programs, is able to rapidly extract important datasets that represent the variety of expression patterns available within the data sets, showing potential applications in fields like genomics, proteomics, and bioinformatics

    Dual-initiation promoters with intertwined canonical and TCT/TOP transcription start sites diversify transcript processing

    Get PDF
    Variations in transcription start site (TSS) selection reflect diversity of preinitiation complexes and can impact on post-transcriptional RNA fates. Most metazoan polymerase II-transcribed genes carry canonical initiation with pyrimidine/purine (YR) dinucleotide, while translation machinery-associated genes carry polypyrimidine initiator (5’-TOP or TCT). By addressing the developmental regulation of TSS selection in zebrafish we uncovered a class of dual-initiation promoters in thousands of genes, including snoRNA host genes. 5’-TOP/TCT initiation is intertwined with canonical initiation and used divergently in hundreds of dual-initiation promoters during maternal to zygotic transition. Dual-initiation in snoRNA host genes selectively generates host and snoRNA with often different spatio-temporal expression. Dual-initiation promoters are pervasive in human and fruit fly, reflecting evolutionary conservation. We propose that dual-initiation on shared promoters represents a composite promoter architecture, which can function both coordinately and divergently to diversify RNAs

    Characterization of a trimeric light-harvesting complex in the diatom Phaeodactylum tricornutum built of FcpA and FcpE proteins

    Get PDF
    Fucoxanthin chlorophyll proteins (Fcps), the light-harvesting antennas of heterokont algae, are encoded by a multigene family and are highly similar with respect to their molecular masses as well as to their pigmentation, making it difficult to purify single Fcps. In this study, a hexa-histidine tag was genetically added to the C-terminus of the FcpA protein of the pennate diatom Phaeodactylum tricornutum. A transgenic strain expressing the recombinant His-tagged FcpA protein in addition to the endogenous wild type Fcps was created. This strategy allowed, for the first time, the purification of a specific, stable trimeric Fcp complex. In addition, a pool of various trimeric Fcps was also purified from the wild-type cells using sucrose density gradient ultracentrifugation and gel filtration. In both the His-tagged and the wild-type Fcps, excitation energy coupling between fucoxanthin and chlorophyll a was intact and the existence of a chlorophyll a/fucoxanthin excitonic dimer was demonstrated using circular dichroism spectroscopy. Mass spectrometric analyses of the trimeric His-tagged complex indicated that it is composed of FcpA and FcpE polypeptides. It is confirmed here that a trimer is the basic organizational unit of Fcps in P. tricornutum. From circular dichroism spectra, it is proposed that the organization of the pigments on the polypeptide backbone of Fcps is a conserved feature in the case of chlorophyll a/c containing algae

    Size-fractionated labile trace elements in the Northwest Pacific and Southern Oceans

    Get PDF
    Author Posting. © The Author(s), 2011. This is the author's version of the work. It is posted here by permission of Elsevier B.V. for personal use, not for redistribution. The definitive version was published in Marine Chemistry 126 (2011): 108-113, doi:10.1016/j.marchem.2011.04.004.Photosynthesis by marine phytoplankton requires bioavailable forms of several trace elements that are found in extremely low concentrations in the open ocean. We have compared the concentration, lability and size distribution (< 1 nm and < 10 nm) of a suite of trace elements that are thought to be limiting to primary productivity as well as a toxic element (Pb) in two High Nutrient Low Chlorophyll (HNLC) regions using a new dynamic speciation technique, Diffusive Gradients in Thin-film (DGT). The labile species trapped within the DGT probes have a size that is smaller or similar than the pore size of algal cell walls and thus present a proxy for bioavailable species. Total Dissolvable trace element concentrations (TD concentration) varied between 0.05 nM (Co) and 4.0 nM (Ni) at K2 (Northwest Pacific Ocean) and between 0.026 nM (Co) and 4.7 nM (Ni) in the Southern Ocean. The smallest size fractionated labile concentrations (< 1 nm) observed at Southern Ocean sampling stations ranged between 0.002 nM (Co) and 2.1 nM (Ni). Moreover, large differences in bioavailable fractions (ratio of labile to TD concentration) were observed between the trace elements. In the Northwest Pacific Ocean Fe, Cu and Mn had lower labile fractions (between 10 and 44%) than Co, Cd, Ni and Pb (between 80 and 100%). In the Southern Ocean a similar trend was observed, and in addition: (1) Co, Cd, Ni and Pb have lower labile fractions in the Southern Ocean than in the Northwest Pacific and (2) the ratios of <1nm to dissolvable element concentrations at some Southern Ocean stations were very low and varied between 4 and16 %.This research was supported by Federal Science Policy Office, Brussels, through contracts EV/03/7A, SD/CA/03A, the Research Foundation Flanders through grant G.0021.04 and Vrije Universiteit Brussel via grant GOA 22, as well as for K2, the VERTIGO program funding primarily by the US National Science Foundation programs in Chemical and Biological Oceanograph

    The association between retraction of the torn rotator cuff and increasing expression of hypoxia inducible factor 1α and vascular endothelial growth factor expression: an immunohistological study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Differing levels of tendon retraction are found in full-thickness rotator cuff tears. The pathophysiology of tendon degeneration and retraction is unclear. Neoangiogenesis in tendon parenchyma indicates degeneration. Hypoxia inducible factor 1α (HIF) and vascular endothelial growth factor (VEGF) are important inducers of neoangiogenesis. Rotator cuff tendons rupture leads to fatty muscle infiltration (FI) and muscle atrophy (MA). The aim of this study is to clarify the relationship between HIF and VEGF expression, neoangiogenesis, FI, and MA in tendon retraction found in full-thickness rotator cuff tears.</p> <p>Methods</p> <p>Rotator cuff tendon samples of 33 patients with full-thickness medium-sized rotator cuff tears were harvested during reconstructive surgery. The samples were dehydrated and paraffin embedded. For immunohistological determination of VEGF and HIF expression, sample slices were strained with VEGF and HIF antibody dilution. Vessel density and vessel size were determined after Masson-Goldner staining of sample slices. The extent of tendon retraction was determined intraoperatively according to Patte's classification. Patients were assigned to 4 categories based upon Patte tendon retraction grade, including one control group. FI and MA were measured on standardized preoperative shoulder MRI.</p> <p>Results</p> <p>HIF and VEGF expression, FI, and MA were significantly higher in torn cuff samples compared with healthy tissue (p < 0.05). HIF and VEGF expression, and vessel density significantly increased with extent of tendon retraction (p < 0.05). A correlation between HIF/VEGF expression and FI and MA could be found (p < 0.05). There was no significant correlation between HIF/VEGF expression and neovascularity (p > 0.05)</p> <p>Conclusion</p> <p>Tendon retraction in full-thickness medium-sized rotator cuff tears is characterized by neovascularity, increased VEGF/HIF expression, FI, and MA. VEGF expression and neovascularity may be effective monitoring tools to assess tendon degeneration.</p
    corecore