509 research outputs found

    Light-by-light-type corrections to the muon anomalous magnetic moment at four-loop order

    Full text link
    The numerically dominant QED contributions to the anomalous magnetic moment of the muon stem from Feynman diagrams with internal electron loops. We consider such corrections and present a calculation of the four-loop light-by-light-type corrections where the external photon couples to a closed electron or muon loop. We perform an asymptotic expansion in the ratio of electron and muon mass and reduce the resulting integrals to master integrals which we evaluate using analytical and numerical methods. We confirm the results present in the literature which are based on different computational methods.Comment: 16 page

    Frequency Influences the Regularity of the Structural Variations Present in the Leg Swing Kinematics

    Get PDF
    The regularity of human motor patterns has been linked to age and disease states [1]. For example, the structural variations that are found in a rhythmical finger force task are less regular in the aged and individuals with Parkinson’s disease (PD) [1]. These observed changes represent an inability of the nervous system to integrate the motor-sensory information for the maintenance of a regular motor pattern [1,2]. Currently, it is unknown if the changes in regularity of the structural variations persist while performing a rhythmical motor task with the lower extremity, and if the frequency of the rhythmical pattern influences the regularity. Further exploration of the neuromechanical mechanisms that affect the regularity of the structural variations present in the motor output may lead to development of new biomedical tools that can be used for the assessment and management of movement disorders. The aim of this study was to identify neuromechanical factors associated with changes in kinematic regularity of the structural variations present in a simple rhythmic leg swing task. A leg swing task was used to explore the neuromechanical factors that govern the regularity of the structural variations present in the motor output. Young (n=9, Age=19.9+1.3 yrs.), aged (n=9; Age= 74.7+6.1 yrs.) and individuals with PD (n=9, Age=73.4+6.6) participated in the study. PD individuals had a Hoehn-Yahr score between 2 and 3, and performed the experiment while “on” levodopa therapy. Participants swung their leg at their preferred pendular frequency, and frequencies that were 20% faster and slower. Metronome was used to help the participants maintain the prescribed frequency. Participants swung their leg for two minutes at each frequency. Approximate Entropy was used to measure the regularity of the structural variations present in the leg swing kinematic data collected by electronic goniometer (100 Hz) [1,3]. Repeated measures design with a 0.05 alpha level was used for statistical analyses of the data. The main effects for frequency were significantly different (p\u3c0.001), and less regular structural variations were associated with faster frequencies. The group main effects were significantly different (p\u3c0.05). The regularity of the structural variations present in the leg swing kinematics of the aged group were not significantly different than the young at all frequencies (p\u3e0.05). The regularity of the structural variations present in the PD group’s leg swing kinematics were significantly different than the aged and young at all frequencies (p\u3c0.05). Our results indicate that the regularity of the structural variations present in a leg swinging task are influenced by the frequency of the movement pattern. However, the regularity of these variations are not influenced by age. This indicates that changes in the regularity of the structural variations are not consistent for the upper and lower extremities in the aged. PD resulted in less regular structural variations at all movement frequencies. This suggests that the basal ganglia plays a large role in the control of the regularity of the structural variations present in a rhythmical task. Our results present a foundation for future research on development of new biomedical tools for the assessment and management of PD

    Scaling Dynamic Response and Destructive Metabolism in an Immunosurveillant Anti-Tumor System Modulated by Different External Periodic Interventions

    Get PDF
    On the basis of two universal power-law scaling laws, i.e. the scaling dynamic hysteresis in physics and the allometric scaling metabolism in biosystem, we studied the dynamic response and the evolution of an immunosurveillant anti-tumor system subjected to a periodic external intervention, which is equivalent to the scheme of a radiotherapy or chemotherapy, within the framework of the growth dynamics of tumor. Under the modulation of either an abrupt or a gradual change external intervention, the population density of tumors exhibits a dynamic hysteresis to the intervention. The area of dynamic hysteresis loop characterizes a sort of dissipative-therapeutic relationship of the dynamic responding of treated tumors with the dose consumption of accumulated external intervention per cycle of therapy. Scaling the area of dynamic hysteresis loops against the intensity of an external intervention, we deduced a characteristic quantity which was defined as the theoretical therapeutic effectiveness of treated tumor and related with the destructive metabolism of tumor under treatment. The calculated dose-effectiveness profiles, namely the dose cumulant per cycle of intervention versus the therapeutic effectiveness, could be well scaled into a universal quadratic formula regardless of either an abrupt or a gradual change intervention involved. We present a new concept, i.e., the therapy-effect matrix and the dose cumulant matrix, to expound the new finding observed in the growth and regression dynamics of a modulated anti-tumor system

    Rationale and design of the PeriOperative ISchemic Evaluation-3 (POISE-3) : a randomized controlled trial evaluating tranexamic acid and a strategy to minimize hypotension in noncardiac surgery

    Get PDF
    Altres ajuts: Canadian Institutes of Health Research (CIHR, FDN-143302); General Research Fund (14104419), Research Grant Council, Hong Kong SAR, China; National Health and Medical Research Council, Funding Schemes (NHMRC Project Grant 1162362), Australia; McMaster University Department of Medicine Career Research Award and a Physicians' Services Incorporated (PSI) Foundation Mid-Career Clinical Research Award.Background: For patients undergoing noncardiac surgery, bleeding and hypotension are frequent and associated with increased mortality and cardiovascular complications. Tranexamic acid (TXA) is an antifibrinolytic agent with the potential to reduce surgical bleeding; however, there is uncertainty about its efficacy and safety in noncardiac surgery. Although usual perioperative care is commonly consistent with a hypertension-avoidance strategy (i.e., most patients continue their antihypertensive medications throughout the perioperative period and intraoperative mean arterial pressures of 60 mmHg are commonly accepted), a hypotension-avoidance strategy may improve perioperative outcomes. Methods: The PeriOperative Ischemic Evaluation (POISE)-3 Trial is a large international randomized controlled trial designed to determine if TXA is superior to placebo for the composite outcome of life-threatening, major, and critical organ bleeding, and non-inferior to placebo for the occurrence of major arterial and venous thrombotic events, at 30 days after randomization. Using a partial factorial design, POISE-3 will additionally determine the effect of a hypotension-avoidance strategy versus a hypertension-avoidance strategy on the risk of major cardiovascular events, at 30 days after randomization. The target sample size is 10,000 participants. Patients ≄45 years of age undergoing noncardiac surgery, with or at risk of cardiovascular and bleeding complications, are randomized to receive a TXA 1 g intravenous bolus or matching placebo at the start and at the end of surgery. Patients, health care providers, data collectors, outcome adjudicators, and investigators are blinded to the treatment allocation. Patients on ≄ 1 chronic antihypertensive medication are also randomized to either of the two blood pressure management strategies, which differ in the management of patient antihypertensive medications on the morning of surgery and on the first 2 days after surgery, and in the target mean arterial pressure during surgery. Outcome adjudicators are blinded to the blood pressure treatment allocation. Patients are followed up at 30 days and 1 year after randomization. Discussion: Bleeding and hypotension in noncardiac surgery are common and have a substantial impact on patient prognosis. The POISE-3 trial will evaluate two interventions to determine their impact on bleeding, cardiovascular complications, and mortality. Trial registration: ClinicalTrials.gov NCT03505723. Registered on 23 April 2018

    Status of the BELLE II Pixel Detector

    Get PDF
    The Belle II experiment at the super KEK B-factory (SuperKEKB) in Tsukuba, Japan, has been collecting e+e−e^+e^− collision data since March 2019. Operating at a record-breaking luminosity of up to 4.7×1034cm−2s−14.7×10^{34} cm^{−2}s^{−1}, data corresponding to 424fb−1424 fb^{−1} has since been recorded. The Belle II VerteX Detector (VXD) is central to the Belle II detector and its physics program and plays a crucial role in reconstructing precise primary and decay vertices. It consists of the outer 4-layer Silicon Vertex Detector (SVD) using double sided silicon strips and the inner two-layer PiXel Detector (PXD) based on the Depleted P-channel Field Effect Transistor (DePFET) technology. The PXD DePFET structure combines signal generation and amplification within pixels with a minimum pitch of (50×55)ÎŒm2(50×55) ÎŒm^2. A high gain and a high signal-to-noise ratio allow thinning the pixels to 75ÎŒm75 ÎŒm while retaining a high pixel hit efficiency of about 9999%. As a consequence, also the material budget of the full detector is kept low at ≈0.21≈0.21%XX0\frac{X}{X_0} per layer in the acceptance region. This also includes contributions from the control, Analog-to-Digital Converter (ADC), and data processing Application Specific Integrated Circuits (ASICs) as well as from cooling and support structures. This article will present the experience gained from four years of operating PXD; the first full scale detector employing the DePFET technology in High Energy Physics. Overall, the PXD has met the expectations. Operating in the intense SuperKEKB environment poses many challenges that will also be discussed. The current PXD system remains incomplete with only 20 out of 40 modules having been installed. A full replacement has been constructed and is currently in its final testing stage before it will be installed into Belle II during the ongoing long shutdown that will last throughout 2023

    Coulomb dissociation of N 20,21

    Get PDF
    Neutron-rich light nuclei and their reactions play an important role in the creation of chemical elements. Here, data from a Coulomb dissociation experiment on N20,21 are reported. Relativistic N20,21 ions impinged on a lead target and the Coulomb dissociation cross section was determined in a kinematically complete experiment. Using the detailed balance theorem, the N19(n,Îł)N20 and N20(n,Îł)N21 excitation functions and thermonuclear reaction rates have been determined. The N19(n,Îł)N20 rate is up to a factor of 5 higher at

    Particle-flow reconstruction and global event description with the CMS detector

    Get PDF
    The CMS apparatus was identified, a few years before the start of the LHC operation at CERN, to feature properties well suited to particle-flow (PF) reconstruction: a highly-segmented tracker, a fine-grained electromagnetic calorimeter, a hermetic hadron calorimeter, a strong magnetic field, and an excellent muon spectrometer. A fully-fledged PF reconstruction algorithm tuned to the CMS detector was therefore developed and has been consistently used in physics analyses for the first time at a hadron collider. For each collision, the comprehensive list of final-state particles identified and reconstructed by the algorithm provides a global event description that leads to unprecedented CMS performance for jet and hadronic tau decay reconstruction, missing transverse momentum determination, and electron and muon identification. This approach also allows particles from pileup interactions to be identified and enables efficient pileup mitigation methods. The data collected by CMS at a centre-of-mass energy of 8 TeV show excellent agreement with the simulation and confirm the superior PF performance at least up to an average of 20 pileup interactions

    Identification of heavy-flavour jets with the CMS detector in pp collisions at 13 TeV

    Get PDF
    Many measurements and searches for physics beyond the standard model at the LHC rely on the efficient identification of heavy-flavour jets, i.e. jets originating from bottom or charm quarks. In this paper, the discriminating variables and the algorithms used for heavy-flavour jet identification during the first years of operation of the CMS experiment in proton-proton collisions at a centre-of-mass energy of 13 TeV, are presented. Heavy-flavour jet identification algorithms have been improved compared to those used previously at centre-of-mass energies of 7 and 8 TeV. For jets with transverse momenta in the range expected in simulated tt‟\mathrm{t}\overline{\mathrm{t}} events, these new developments result in an efficiency of 68% for the correct identification of a b jet for a probability of 1% of misidentifying a light-flavour jet. The improvement in relative efficiency at this misidentification probability is about 15%, compared to previous CMS algorithms. In addition, for the first time algorithms have been developed to identify jets containing two b hadrons in Lorentz-boosted event topologies, as well as to tag c jets. The large data sample recorded in 2016 at a centre-of-mass energy of 13 TeV has also allowed the development of new methods to measure the efficiency and misidentification probability of heavy-flavour jet identification algorithms. The heavy-flavour jet identification efficiency is measured with a precision of a few per cent at moderate jet transverse momenta (between 30 and 300 GeV) and about 5% at the highest jet transverse momenta (between 500 and 1000 GeV)
    • 

    corecore