2,088 research outputs found
The influence of magnetic order on the magnetoresistance anisotropy of FeCuTe
We performed resistance measurements on FeCuTe with
in the presence of in-plane applied magnetic fields,
revealing a resistance anisotropy that can be induced at a temperature far
below the structural and magnetic zero-field transition temperatures. The
observed resistance anisotropy strongly depends on the field orientation with
respect to the crystallographic axes, as well as on the field-cooling history.
Our results imply a correlation between the observed features and the
low-temperature magnetic order. Hysteresis in the angle-dependence indicates a
strong pinning of the magnetic order within a temperature range that varies
with the Cu content. The resistance anisotropy vanishes at different
temperatures depending on whether an external magnetic field or a remnant field
is present: the closing temperature is higher in the presence of an external
field. For the resistance anisotropy closes above the
structural transition, at the same temperature at which the zero-field
short-range magnetic order disappears and the sample becomes paramagnetic. Thus
we suggest that under an external magnetic field the resistance anisotropy
mirrors the magnetic order parameter. We discuss similarities to nematic order
observed in other iron pnictide materials.Comment: 11 pages, 9 figure
Tracking Energy Flow Using a Volumetric Acoustic Intensity Imager (VAIM)
A new measurement device has been invented at the Naval Research Laboratory which images instantaneously the intensity vector throughout a three-dimensional volume nearly a meter on a side. The measurement device consists of a nearly transparent spherical array of 50 inexpensive microphones optimally positioned on an imaginary spherical surface of radius 0.2m. Front-end signal processing uses coherence analysis to produce multiple, phase-coherent holograms in the frequency domain each related to references located on suspect sound sources in an aircraft cabin. The analysis uses either SVD or Cholesky decomposition methods using ensemble averages of the cross-spectral density with the fixed references. The holograms are mathematically processed using spherical NAH (nearfield acoustical holography) to convert the measured pressure field into a vector intensity field in the volume of maximum radius 0.4 m centered on the sphere origin. The utility of this probe is evaluated in a detailed analysis of a recent in-flight experiment in cooperation with Boeing and NASA on NASA s Aries 757 aircraft. In this experiment the trim panels and insulation were removed over a section of the aircraft and the bare panels and windows were instrumented with accelerometers to use as references for the VAIM. Results show excellent success at locating and identifying the sources of interior noise in-flight in the frequency range of 0 to 1400 Hz. This work was supported by NASA and the Office of Naval Research
Reconstruction of the Acoustic Field Using a Conformal Array
Near-field acoustical holography (NAH) requires the measurement of the near-field pressure field over a conformal and closed surface in order to recover the acoustic field on a nearby surface. We are interested in the reconstruction of the acoustic field over the fuselage of a Boeing 757 airplane when pressure data is available over an array of microphones that are conformal to the fuselage surface. In this case the strict NAH theory does not hold, but still there are techniques used to overcome this difficulty. The best known is patch NAH, which has been used for planar surfaces. In this work we will discuss two new techniques used for surfaces with an arbitrarily shape: patch inverse boundary element methods (IBEM) and patch equivalent sources method (ESM). We will discuss the theoretical justification of the method and show reconstructions for in-flight data taken inside a Boeing 757 airplane
Spin dynamics near a putative antiferromagnetic quantum critical point in Cu substituted BaFeAs and its relation to high-temperature superconductivity
We present the results of elastic and inelastic neutron scattering
measurements on non-superconducting
Ba(FeCu)As, a composition close to a
quantum critical point between AFM ordered and paramagnetic phases. By
comparing these results with the spin fluctuations in the low Cu composition as
well as the parent compound BaFeAs and superconducting
Ba(FeNi)As compounds, we demonstrate that paramagnon-like
spin fluctuations are evident in the antiferromagnetically ordered state of
Ba(FeCu)As, which is distinct from the AFM-like
spin fluctuations in the superconducting compounds. Our observations suggest
that Cu substitution decouples the interaction between quasiparticles and the
spin fluctuations. We also show that the spin-spin correlation length,
, increases rapidly as the temperature is lowered and find
scaling behavior, the hallmark of quantum criticality, at an
antiferromagnetic quantum critical point.Comment: 10 pages, 7 figure
Experimental elucidation of the origin of the `double spin resonances' in Ba(FeCo)As
We report a combined study of the spin resonances and superconducting gaps
for underdoped ( K), optimally doped ( K), and overdoped
( K) Ba(FeCo)As single crystals with inelastic
neutron scattering and angle resolved photoemission spectroscopy. We find a
quasi two dimensional spin resonance whose energy scales with the
superconducting gap in all three compounds. In addition, anisotropic low energy
spin excitation enhancements in the superconducting state have been deduced and
characterized for the under and optimally doped compounds. Our data suggest
that the quasi two dimensional spin resonance is a spin exciton that
corresponds to the spin singlet-triplet excitations of the itinerant electrons.
However, the intensity enhancements of the anisotropic spin excitations are
dominated by the out-of-plane spin excitations of the ordered moments due to
the suppression of damping in the superconducting state. Hence we offer a new
interpretation of the double energy scales differing from previous
interpretations based on anisotropic superconducting energy gaps, and
systematically explain the doping-dependent trend across the phase diagram.Comment: 8 pages, 7 figures, 1 table. Accepted for publication on Physical
Review
Prevalence of and Factors Associated with Negative Microscopic Diagnosis of Cutaneous Leishmaniasis in Rural Peru.
Cutaneous leishmaniasis is endemic to South America where diagnosis is most commonly conducted via microscopy. Patients with suspected leishmaniasis were referred for enrollment by the Ministry of Health (MoH) in Lima, Iquitos, Puerto Maldonado, and several rural areas of Peru. A 43-question survey requesting age, gender, occupation, characterization of the lesion(s), history of leishmaniasis, and insect-deterrent behaviors was administered. Polymerase chain reaction (PCR) was conducted on lesion materials at the Naval Medical Research Unit No. 6 in Lima, and the results were compared with those obtained by the MoH using microscopy. Factors associated with negative microscopy and positive PCR results were identified using
Heat capacity study of BaFeAs: effects of annealing
Heat-capacity, X-ray diffraction, and resistivity measurements on a
high-quality BaFeAs sample show an evolution of the
magneto-structural transition with successive annealing periods. After a 30-day
anneal the resistivity in the (ab) plane decreases by more than an order of
magnitude, to 12 cm, with a residual resistance ratio 36; the
heat-capacity anomaly at the transition sharpens, to an overall width of less
than K, and shifts from 135.4 to 140.2 K. The heat-capacity anomaly in both the
as-grown sample and after the 30-day anneal shows a hysteresis of 0.15 K,
and is unchanged in a magnetic field H = 14 T. The X-ray and
heat-capacity data combined suggest that there is a first order jump in the
structural order parameter. The entropy of the transition is reported
Acoustic Source Localization in Aircraft Interiors Using Microphone Array Technologies
Using three microphone array configurations at two aircraft body stations on a Boeing 777-300ER flight test, the acoustic radiation characteristics of the sidewall and outboard floor system are investigated by experimental measurement. Analysis of the experimental data is performed using sound intensity calculations for closely spaced microphones, PATCH Inverse Boundary Element Nearfield Acoustic Holography, and Spherical Nearfield Acoustic Holography. Each method is compared assessing strengths and weaknesses, evaluating source identification capability for both broadband and narrowband sources, evaluating sources during transient and steady-state conditions, and quantifying field reconstruction continuity using multiple array positions
The Simplified Geneva Score and the Utilization of the D-Dimer and Computerized Tomography for Assessing Pulmonary Embolism
Background. Pulmonary embolism (PE) is clinically suspected in many patients who complain of shortness of breath or chest pain due to its nonspecific nature. The prevalence of PE, however, is low in this population. To assist physicians in diagnostic decision making, several clinical decision rules (CDR) have been developed. The appropriate use of these CDRs has been proven to decrease the need for expensive, time consuming, and invasive diagnostic imaging procedures. In this study, the appropriateness of D-dimer and CT usage was investigated to rule out pulmonary emboli based on the simplified Geneva score. Methods. A retrospective review was performed on 74 patients with a CT scan ordered through a pulmonary embolism (PE) protocol. Using clinical data, the patients were stratified into “unlikely” and “likely” groups for the presence of PE based on the simplification of the revised Geneva score. Scores of 0-2 were graded as “unlikely” and scores of 3 or greater were “likely.” Results. There were 45/74 (60.8%) patients in the “unlikely” group. Of these, 14/45 (31.1%) received a D-dimer; eight were normal and six elevated. Only one patient in the elevated group had evidence of a PE. Of the remaining 31(39.2%) patients in the “unlikely” group that did not receive a D-dimer, only one had a PE. The “likely” group consisted of 29 (39.2%) patients of whom six received a D-dimer. Three patients had a normal D-dimer and three had an elevated level. Neither of these two groups had a PE. Of the remaining 23 (60.8%) in the “likely” group who did not receive a D-dimer, six had a PE. Conclusions. Diagnosing pulmonary emboli using D-dimer levels and CT scans may be aided by clinical decision rules such as the simplified Geneva system. This process may lead to more effective use of medical resources
- …
