240 research outputs found
Unconventional carrier-mediated ferromagnetism above room temperature in ion-implanted (Ga, Mn)P:C
Ion implantation of Mn ions into hole-doped GaP has been used to induce
ferromagnetic behavior above room temperature for optimized Mn concentrations
near 3 at.%. The magnetism is suppressed when the Mn dose is increased or
decreased away from the 3 at.% value, or when n-type GaP substrates are used.
At low temperatures the saturated moment is on the order of one Bohr magneton,
and the spin wave stiffness inferred from the Bloch-law T^3/2 dependence of the
magnetization provides an estimate Tc = 385K of the Curie temperature that
exceeds the experimental value, Tc = 270K. The presence of ferromagnetic
clusters and hysteresis to temperatures of at least 330K is attributed to
disorder and proximity to a metal-insulating transition.Comment: 4 pages, 4 figures (RevTex4
Simulation of a Shear Coaxial GO2/GH2 Rocket Injector with DES and LES Using Flamelet Models
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/97098/1/AIAA2012-3744.pd
The Thermal Behaviour of Three Different Auger Pressure Grouted Piles Used as Heat Exchangers
Three auger pressure grouted (APG) test piles were constructed at a site in Richmond, Texas. The piles were each equipped with two U-loops of heat transfer pipes so that they could function as pile heat exchangers. The piles were of two different diameters and used two different grouts, a standard APG grout and a thermally enhanced grout. Thermal response tests, where fluid heated at a constant rate is circulated through the pipe loops, were carried out on the three piles, utilising either single or double loops. The resulting test data can be used to determine the surrounding soil thermal conductivity and the pile thermal resistance, both essential design parameters for ground source heat pump systems using pile heat exchangers. This paper uses parameter estimation techniques to fit empirical temperature response curves to the thermal response test data and compares the results with standard line source interpretation techniques. As expected, the thermal response tests with double loops result in smaller thermal resistances than the same pile when the test was run with a single loop. Back analysis of the pile thermal resistance also allows calculation of the grout thermal properties. The thermally enhanced grout is shown to have inferior thermal properties than the standard APG grout. Together these analyses demonstrate the importance of pile size, grout thermal properties and pipe positions in controlling the thermal behaviour of heat exchanger piles
Comparison of two different models for pile thermal response test interpretation
Thermal response tests (TRTs) are regularly used to characterise the thermal resistance of borehole heat exchangers and to assess the thermal conductivity of the surrounding ground. It is becoming common to apply the same in situ testing technique to pile heat exchangers, despite international guidance suggesting that TRTs should be limited to hole diameters of 152 mm (6 in.). This size restriction arises from the increased thermal inertia of larger diameter heat exchangers, which invalidates the assumption of a steady state within the concrete needed to interpret the test data by traditional line source analysis techniques. However, new methods of analysis for pile heat exchangers have recently been developed that take account of the transient behaviour of the pile concrete. This paper applies these new methods to data from a multi-stage TRT conducted on a small diameter test pile. The thermal conductivity and thermal resistance determined using this method are then compared with those from traditional analytical approaches based on a line source analysis. Differences between the approaches are discussed, along with the observation that the thermal resistance may not be constant over the different test stages
Effect of mean void fraction correlations on a shell-and-tube evaporator dynamic model performance
In this paper, the influence of different mean void fraction correlations on a shell-and-tube evaporator dynamic model performance has been evaluated. The model proposed is based on the moving boundary approach and includes the expansion valve modelling. Several transient tests, using R134a as working fluid, have been carried out varying refrigerant mass flow, inlet enthalpy and secondary fluid flow. Then, the model performance, using different mean void fractions, is analysed from the system model outputs (evaporating pressure, refrigerant outlet temperature and condensing water outlet temperature). The slip ratio expressions selected are: homogenous, momentum flux model, Zivi's, Chisholm's and Smith's correlations. The results of the comparison between experimental and model predictions depend on the transient characteristics and there is not a single slip ratio correlation that provides the best performance in all the cases analysed.Navarro-EsbrĂ, J.; Milián Sánchez, V.; Mota Babiloni, A.; MolĂ©s Ribera, F.; VerdĂş MartĂn, GJ. (2015). Effect of mean void fraction correlations on a shell-and-tube evaporator dynamic model performance. Science and Technology for the Built Environment. 21(7):1057-1072. doi:10.1080/23744731.2015.1034594S1057107221
A review on the heat and mass transfer phenomena in nanofluid coolants with special focus on automotive applications
Engineered suspensions of nanosized particles (nanofluids) are characterized by superior thermal properties. Due to the increasing need for ultrahigh performance cooling in many industries, nanofluids have been widely investigated as next-generation coolants. However, the multiscale nature of nanofluids implies nontrivial relations between their design characteristics and the resulting thermo-physical properties, which are far from being fully understood. This pronounced sensitivity is the main reason for some contradictory results among both experimental evidence and theoretical considerations presented in the literature. In this Review, the role of fundamental heat and mass transfer mechanisms governing thermo-physical properties of nanofluids is assessed, from both experimental and theoretical point of view. Starting from the characteristic nanoscale transport phenomena occurring at the particle-fluid interface, a comprehensive review of the influence of geometrical (particle shape, size and volume concentration), physical (temperature) and chemical (particle material, pH and surfactant concentration in the base fluid) parameters on the nanofluid properties was carried out. Particular focus was devoted to highlight the advantages of using nanofluids as coolants for automotive heat exchangers, and a number of design guidelines was suggested for balancing thermal conductivity and viscosity enhancement in nanofluids. This Review may contribute to a more rational design of the thermo-physical properties of particle suspensions, therefore easing the translation of nanofluid technology from small-scale research laboratories to large-scale industrial applications
- …