86 research outputs found

    A Narrative Review on the Unexplored Potential of Colostrum as a Preventative Treatment and Therapy for Diarrhea in Neonatal Dairy Calves

    Get PDF
    Diarrhea is the leading cause of morbidity and mortality in pre-weaned dairy calves and, as such, represents a significant animal health and welfare concern. Furthermore, digestive disease early in life is associated with several long-term consequences such as reduced growth rate and decreased milk yield during the first lactation, thus generating severe economic losses. The majority of diarrheic cases in young calves are treated with antimicrobials; however, it is necessary to develop alternative treatments, as excessive antimicrobial usage can lead to antimicrobial resistance and can negatively impact the gut microflora of a calf. Bovine colostrum is abundant in immune and bioactive factors that improve immune function and development. This rich and natural combination of immunoglobulins, natural antimicrobial factors, growth factors, anti-inflammatories and nutrients may be an attractive alternative to antimicrobials in the treatment of diarrhea in young dairy calves. There is evidence that supports the use of colostrum as an early treatment for diarrhea in young calves. Future research should investigate its therapeutic and economic effectiveness

    Investigation into levels of dioxins, furans, polychlorinated biphenyls and brominated flame retardants in fishery produce in Ireland

    Get PDF
    The Food Safety Authority of Ireland in collaboration with the Marine Institute and An Board Iascaigh Mhara (Sea Fisheries Board) has carried out a surveillance study of levels of dioxins (PCDDs), furans (PCDFs) polychlorinated biphenyls (PCBs), and brominated flame retardants (BFRs), specifically polybrominated diphenylethers (PBDEs) and hexabromocyclododecane (HBCD), in a variety of fish species and fishery products, including fresh and processed products available on the Irish market. The study was undertaken because of concern about the possible effects on human health of these bio-persistent environmental contaminants, known to be present in a number of foodstuffs, notably meat, fish, eggs and dairy products. The study showed that levels of PCDDs and PCDFs in Irish fish and fishery products available on the Irish market were well below existing EC legal limits for these contaminants as laid down in Regulation 466/2001. The lowest level was found in a sample of canned tuna (0.012 ng WHO TEQ/kg whole weight) with the highest level found in a farmed salmon sample (0.82 ng WHO TEQ/kg whole weight), compared with the maximum level under the legislation of 4 ng WHO TEQ/kg whole weight. The levels found were also below the new limits for dioxin-like PCBs (dl-PCBs) and for the sum of WHO-TEQs for PCDDs, PCDFs and dioxin-like PCBs, which were introduced in November, 2006 via Regulation 199/2006. The upper-bound mean levels of PCDDs, PCDFs and dioxin-like PCBs expressed as total WHOTEQs ranged from 0.05 – 2.15 ng/kg WHO TEQ whole weight, which can be compared with the new maximum level of 8 ng WHO TEQ/kg whole weight for the sum of PCDDs, PCDFs and dioxin-like PCBs. Results of this study are in line with those from previous FSAI studies on PCDD and PCDF levels in fish and also in meat, milk and eggs, and indicate relatively low levels of these contaminants in fishery produce available in the Irish marketplace. Reductions of PCDD/Fs and dl-PCBs in Irish farmed salmon were observed in comparison to levels measured in a previous FSAI/MI survey in 2001, in which a mean level of 4.02 ng WHO TEQ/kg whole weight was detected compared with 2.15 ng/kg WHO TEQ whole weight in the present study. Similar observations can be made for levels reported in a study carried out by An Board Iascaigh Mhara in 2004, in which a mean level of 1.75 ng WHO TEQ/kg whole weight was reported. Concentrations of brominated flame retardants were also low. The mean PBDE concentrations ranged from <0.31 to 3.71 µg/kg whole weight in canned tuna to farmed salmon respectively. Although there are no acceptable daily intake (ADI) or maximum limits set for PBDEs or HBCD, the levels of these contaminants found in the study were low, and are very unlikely to present a health risk to Irish consumers. Although fish is a recognised dietary source of PCDDs, PCDFs and PCBs, the health benefits of eating fish are well established, and on the basis of these results the FSAI considers that there is no need to alter current advice on fish consumption. Current advice is that consumers should eat two portions of fish a week, one of which should be oily. The full study report follows, providing further sampling details, analytical methodologies and discussion of the resulting datasets.Funder: Marine Institut

    Precision scans of the pixel cell response of double sided 3D pixel detectors to pion and x-ray beams

    Get PDF
    hree-dimensional (3D) silicon sensors offer potential advantages over standard planar sensors for radiation hardness in future high energy physics experiments and reduced charge-sharing for X-ray applications, but may introduce inefficiencies due to the columnar electrodes. These inefficiencies are probed by studying variations in response across a unit pixel cell in a 55μm pitch double-sided 3D pixel sensor bump bonded to TimePix and Medipix2 readout ASICs. Two complementary characterisation techniques are discussed: the first uses a custom built telescope and a 120GeV pion beam from the Super Proton Synchrotron (SPS) at CERN; the second employs a novel technique to illuminate the sensor with a micro-focused synchrotron X-ray beam at the Diamond Light Source, UK. For a pion beam incident perpendicular to the sensor plane an overall pixel efficiency of 93.0±0.5% is measured. After a 10o rotation of the device the effect of the columnar region becomes negligible and the overall efficiency rises to 99.8±0.5%. The double-sided 3D sensor shows significantly reduced charge sharing to neighbouring pixels compared to the planar device. The charge sharing results obtained from the X-ray beam study of the 3D sensor are shown to agree with a simple simulation in which charge diffusion is neglected. The devices tested are found to be compatible with having a region in which no charge is collected centred on the electrode columns and of radius 7.6±0.6μm. Charge collection above and below the columnar electrodes in the double-sided 3D sensor is observed

    Ni-62(n,gamma) and Ni-63(n,gamma) cross sections measured at the n_TOF facility at CERN

    Get PDF
    The cross section of the Ni-62(n,gamma) reaction was measured with the time-of-flight technique at the neutron time-of-flight facility n_TOF at CERN. Capture kernels of 42 resonances were analyzed up to 200 keV neutron energy and Maxwellian averaged cross sections (MACS) from kT = 5-100 keV were calculated. With a total uncertainty of 4.5%, the stellar cross section is in excellent agreement with the the KADoNiS compilation at kT = 30 keV, while being systematically lower up to a factor of 1.6 at higher stellar temperatures. The cross section of the Ni-63(n,gamma) reaction was measured for the first time at n_TOF. We determined unresolved cross sections from 10 to 270 keV with a systematic uncertainty of 17%. These results provide fundamental constraints on s-process production of heavier species, especially the production of Cu in massive stars, which serve as the dominant source of Cu in the solar system.Peer reviewedFinal Accepted Versio

    The UA9 experimental layout

    Full text link
    The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.Comment: 15pages, 11 figure, submitted to JINS

    Charge sharing suppression using pixel-to-pixel communication in photon counting X-ray imaging systems

    No full text
    In planar silicon detector structures, the charge sharing between pixels is one limiting factor for colour X-ray imaging using integrated photon counting pixel detectors. 3D detector structures have been proposed as one solution to this problem. However, there are also readout system solutions to the problem, i.e., introducing pixel-to-pixel communication and distributed charge summing in the readout electronics. In this work, different charge summing schemes are evaluated using Monte Carlo simulation techniques. The increase in electronic noise introduced by the charge summing is one of the most severe problems. A proper selection of summing scheme is necessary to obtain an efficient system

    Characterisation of an epitaxial GaAs/Medipix2 detector using fluorescence photons

    No full text
    Abstract A high-purity GaAs sensor of 110 μm thickness has been bump bonded to a Medipix2 readout chip. The room temperature spectroscopic response of this device to fluorescence photons in the energy range from 8 to 28 keV is presented and compared to the response of a 300 μm thick Si sensor, also bonded to a Medipix2 chip. The measured photopeak responses are used to calibrate both detectors. The depth of depletion of the GaAs sensor is estimated to be 50 μm at 140 V sensor bias voltage from measurements made using the 8 keV Kα line of a Cu target X-ray tube
    • …
    corecore