4 research outputs found

    Determining the polarization state of an extreme ultraviolet free-electron laser beam using atomic circular dichroism

    Get PDF
    Ultrafast extreme ultraviolet and X-ray free-electron lasers are set to revolutionize many domains such as bio-photonics and materials science, in a manner similar to optical lasers over the past two decades. Although their number will grow steadily over the coming decade, their complete characterization remains an elusive goal. This represents a significant barrier to their wider adoption and hence to the full realization of their potential in modern photon sciences. Although a great deal of progress has been made on temporal characterization and wavefront measurements at ultrahigh extreme ultraviolet and X-ray intensities, only few, if any progress on accurately measuring other key parameters such as the state of polarization has emerged. Here we show that by combining ultra-short extreme ultraviolet free electron laser pulses from FERMI with near-infrared laser pulses, we can accurately measure the polarization state of a free electron laser beam in an elegant, non-invasive and straightforward manner using circular dichroism

    Technical design report for the PANDA\overline{{\rm{P}}}\mathrm{ANDA} Barrel DIRC detector

    Get PDF
    The PANDA\overline{{\rm{P}}}\mathrm{ANDA} (anti-Proton ANnihiliation at DArmstadt) experiment will be one of the four flagship experiments at the new international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. PANDA\overline{{\rm{P}}}\mathrm{ANDA} will address fundamental questions of hadron physics and quantum chromodynamics using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c and a design luminosity of up to 2 × 1032 cm−2 s−1. Excellent particle identification (PID) is crucial to the success of the PANDA\overline{{\rm{P}}}\mathrm{ANDA} physics program. Hadronic PID in the barrel region of the target spectrometer will be performed by a fast and compact Cherenkov counter using the detection of internally reflected Cherenkov light (DIRC) technology. It is designed to cover the polar angle range from 22° to 140° and will provide at least 3 standard deviations (s.d.) π/K separation up to 3.5 GeV/c, matching the expected upper limit of the final state kaon momentum distribution from simulation. This documents describes the technical design and the expected performance of the PANDA\overline{{\rm{P}}}\mathrm{ANDA} Barrel DIRC detector. The design is based on the successful BaBar DIRC with several key improvements. The performance and system cost were optimized in detailed detector simulations and validated with full system prototypes using particle beams at GSI and CERN. The final design meets or exceeds the PID goal of clean π/K separation with at least 3 s.d. over the entire phase space of charged kaons in the Barrel DIRC

    Experimental access to Transition Distribution Amplitudes with the P̄ANDA experiment at FAIR

    Get PDF
    Baryon-to-meson Transition Distribution Amplitudes (TDAs) encoding valuable new information on hadron structure appear as building blocks in the collinear factorized description for several types of hard exclusive reactions. In this paper, we address the possibility of accessing nucleon-to-pion (\u3c0N) TDAs from \uafpp \u2192 e+e 12\u3c00 reaction with the future PANDA detector at the FAIR facility. At high center- of-mass energy and high invariant mass squared of the lepton pair q2, the amplitude of the signal channel pp\uaf \u2192 e+e 12\u3c00 admits a QCD factorized description in terms of \u3c0N TDAs and nucleon Distribution Amplitudes (DAs) in the forward and backward kinematic regimes. Assuming the validity of this factorized description, we perform feasibility studies for measuring \uafpp \u2192 e+e 12\u3c00 with the PANDA detector. Detailed simulations on signal reconstruction efficiency as well as on rejection of the most severe background channel, i.e. pp\uaf \u2192 \u3c0+\u3c0 12\u3c00 were performed for the center-of-mass energy squared s = 5 GeV2 and s = 10 GeV2, in the kinematic regions 3.0 0.5 in the proton-antiproton center-of-mass frame. Results of the simulation show that the particle identification capabilities of the PANDA detector will allow to achieve a background rejection factor of 5 \ub7 107 (1 \ub7 107) at low (high) q2 for s = 5 GeV2, and of 1 \ub7 108 (6 \ub7 106) at low (high) q2 for s = 10 GeV2, while keeping the signal reconstruction efficiency at around 40%. At both energies, a clean lepton signal can be reconstructed with the expected statistics corresponding to 2 fb 121 of integrated luminosity. The cross sections obtained from the simulations are used to show that a test of QCD collinear factorization can be done at the lowest order by measuring scaling laws and angular distributions. The future measurement of the signal channel cross section with PANDA will provide a new test of the perturbative QCD description of a novel class of hard exclusive reactions and will open the possibility of experimentally accessing \u3c0N TDAs

    Overview of the randomized trials of radiotherapy in ductal carcinoma in situ of the breast.

    No full text
    Individual patient data were available for all four of the randomized trials that began before 1995, and that compared adjuvant radiotherapy vs no radiotherapy following breast-conserving surgery for ductal carcinoma in situ (DCIS). A total of 3729 women were eligible for analysis. Radiotherapy reduced the absolute 10-year risk of any ipsilateral breast event (ie, either recurrent DCIS or invasive cancer) by 15.2% (SE 1.6%, 12.9% vs 28.1% 2 P <.00001), and it was effective regardless of the age at diagnosis, extent of breast-conserving surgery, use of tamoxifen, method of DCIS detection, margin status, focality, grade, comedonecrosis, architecture, or tumor size. The proportional reduction in ipsilateral breast events was greater in older than in younger women (2P < .0004 for difference between proportional reductions; 10-year absolute risks: 18.5% vs 29.1% at ages <50 years, 10.8% vs 27.8% at ages ≥ 50 years) but did not differ significantly according to any other available factor. Even for women with negative margins and small low-grade tumors, the absolute reduction in the 10-year risk of ipsilateral breast events was 18.0% (SE 5.5, 12.1% vs 30.1%, 2P = .002). After 10 years of follow-up, there was, however, no significant effect on breast cancer mortality, mortality from causes other than breast cancer, or all-cause mortality.Journal ArticleResearch Support, Non-U.S. Gov'tReviewinfo:eu-repo/semantics/publishe
    corecore