296 research outputs found

    Sirolimus-eluting versus uncoated stents in acute myocardial infarction.

    Get PDF
    BACKGROUND: Sirolimus-eluting stents reduce rates of restenosis and reintervention, as compared with uncoated stents. Data are limited regarding the safety and efficacy of such stents in primary percutaneous coronary intervention (PCI) for acute myocardial infarction with ST-segment elevation. METHODS: We performed a single-blind, multicenter, prospectively randomized trial to compare sirolimus-eluting stents with uncoated stents in primary PCI for acute myocardial infarction with ST-segment elevation. The trial included 712 patients at 48 medical centers. The primary end point was target-vessel failure at 1 year after the procedure, defined as target-vessel-related death, recurrent myocardial infarction, or target-vessel revascularization. A follow-up angiographic substudy was performed at 8 months among 174 patients from selected centers. RESULTS: The rate of the primary end point was significantly lower in the sirolimus-stent group than in the uncoated-stent group (7.3% vs. 14.3%, P=0.004). This reduction was driven by a decrease in the rate of target-vessel revascularization (5.6% and 13.4%, respectively; P<0.001). There was no significant difference between the two groups in the rate of death (2.3% and 2.2%, respectively; P=1.00), reinfarction (1.1% and 1.4%, respectively; P=1.00), or stent thrombosis (3.4% and 3.6%, respectively; P=1.00). The degree of neointimal proliferation, as assessed by the mean (+/-SD) in-stent late luminal loss, was significantly lower in the sirolimus-stent group (0.14+/-0.49 mm, vs. 0.83+/-0.52 mm in the uncoated stent group; P<0.001). CONCLUSIONS: Among selected patients with acute myocardial infarction, the use of sirolimus-eluting stents significantly reduced the rate of target-vessel revascularization at 1 year. (ClinicalTrials.gov number, NCT00232830 [ClinicalTrials.gov].)

    Análise ergonômica do trabalho agrícola familiar na produção de leite.

    Get PDF
    Este artigo trata da metodologia utilizada em uma intervenção ergonômica sobre organização do trabalho em Unidades de Produção Agrícola Familiar (UPAF) produtoras de leite de origem bovina, na região oeste da França. Apresenta-se a metodologia utilizada, uma combinação de jornadas de observação e análise do trabalho e jornadas de formação-ação. Discutem-se a Crônica de Ação e o Plano de Utilização das Instalações (PUI), bem como a utilização destes no processo de conscientização do agricultor sobre a complexidade de seu trabalho. Apresenta-se a análise da "supervisão do rebanho", devido ao seu alto grau de complexidade e importância para o desempenho da produção de leite, explorando de que forma certos arranjos espaciais podem favorecer as condições para a realização desta tarefa. Na análise do trabalho agrícola familiar privilegia-se o olhar complexo sobre a situação de trabalho, visando identificar os determinantes, as fontes de variabilidade e as estratégias adotadas

    Usefulness of Routine Fractional Flow Reserve for Clinical Management of Coronary Artery Disease in Patients With Diabetes

    Get PDF
    Importance: Approximately one-third of patients considered for coronary revascularization have diabetes, which is a major determinant of clinical outcomes, often influencing the choice of the revascularization strategy. The usefulness of fractional flow reserve (FFR) to guide treatment in this population is understudied and has been questioned. Objective: To evaluate the usefulness and rate of major adverse cardiovascular events (MACE) of integrating FFR in management decisions for patients with diabetes who undergo coronary angiography. Design, setting, and participants: This cross-sectional study used data from the PRIME-FFR study derived from the merger of the POST-IT study (Portuguese Study on the Evaluation of FFR-Guided Treatment of Coronary Disease [March 2012-November 2013]) and R3F study (French Study of FFR Integrated Multicenter Registries Implementation of FFR in Routine Practice [October 2008-June 2010]), 2 prospective multicenter registries that shared a common design. A population of all-comers for whom angiography disclosed ambiguous lesions was analyzed for rates, patterns, and outcomes associated with management reclassification, including revascularization deferral, in patients with vs without diabetes. Data analysis was performed from June to August 2018. Main outcomes and measures: Death from any cause, myocardial infarction, or unplanned revascularization (MACE) at 1 year. Results: Among 1983 patients (1503 [77%] male; mean [SD] age, 65 [10] years), 701 had diabetes, and FFR was performed for 1.4 lesions per patient (58.2% of lesions in the left anterior descending artery; mean [SD] stenosis, 56% [11%]; mean [SD] FFR, 0.81 [0.01]). Reclassification by FFR was high and similar in patients with and without diabetes (41.2% vs 37.5%, P = .13), but reclassification from medical treatment to revascularization was more frequent in the former (142 of 342 [41.5%] vs 230 of 730 [31.5%], P = .001). There was no statistical difference between the 1-year rates of MACE in reclassified (9.7%) and nonreclassified patients (12.0%) (P = .37). Among patients with diabetes, FFR-based deferral identified patients with a lower risk of MACE at 12 months (25 of 296 [8.4%]) compared with those undergoing revascularization (47 of 257 [13.1%]) (P = .04), and the rate was of the same magnitude of the observed rate among deferred patients without diabetes (7.9%, P = .87). Status of insulin treatment had no association with outcomes. Patients (6.6% of the population) in whom FFR was disregarded had the highest MACE rates regardless of diabetes status. Conclusions and relevance: Routine integration of FFR for the management of coronary artery disease in patients with diabetes may be associated with a high rate of treatment reclassification. Management strategies guided by FFR, including revascularization deferral, may be useful for patients with diabetes.info:eu-repo/semantics/publishedVersio

    Measurement of the neutron magnetic form factor from inclusive quasielastic scattering of polarized electrons from polarized 3He

    Get PDF
    We report a measurement of the asymmetry in spin-dependent quasielastic scattering of longitudinally polarized electrons from a polarized 3He target. The neutron magnetic form factor GMn has been extracted from the measured asymmetry based on recent PWIA calculations using spin-dependent spectral functions. Our determination of GMn at Q2=0.19 (GeV/c)2 agrees with the dipole parametrization. This experiment represents the first measurement of the neutron magnetic form factor using spin-dependent electron scattering

    Second Generation Leptoquark Search in p\bar{p} Collisions at s\sqrt{s} = 1.8 TeV

    Full text link
    We report on a search for second generation leptoquarks with the D\O\ detector at the Fermilab Tevatron ppˉp\bar{p} collider at s\sqrt{s} = 1.8 TeV. This search is based on 12.7 pb1^{-1} of data. Second generation leptoquarks are assumed to be produced in pairs and to decay into a muon and quark with branching ratio β\beta or to neutrino and quark with branching ratio (1β)(1-\beta). We obtain cross section times branching ratio limits as a function of leptoquark mass and set a lower limit on the leptoquark mass of 111 GeV/c2^{2} for β=1\beta = 1 and 89 GeV/c2^{2} for β=0.5\beta = 0.5 at the 95%\ confidence level.Comment: 18 pages, FERMILAB-PUB-95/185-

    Hadron Energy Reconstruction for the ATLAS Calorimetry in the Framework of the Non-parametrical Method

    Get PDF
    This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/he/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. Thus, this technique lends itself to an easy use in a first level trigger. The reconstructed mean values of the hadron energies are within ±1\pm 1% of the true values and the fractional energy resolution is [(58±3)/E+(2.5±0.3)[(58\pm3)% /\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E. The value of the e/he/h ratio obtained for the electromagnetic compartment of the combined calorimeter is 1.74±0.041.74\pm0.04 and agrees with the prediction that e/h>1.7e/h > 1.7 for this electromagnetic calorimeter. Results of a study of the longitudinal hadronic shower development are also presented. The data have been taken in the H8 beam line of the CERN SPS using pions of energies from 10 to 300 GeV.Comment: 33 pages, 13 figures, Will be published in NIM

    Jet Production via Strongly-Interacting Color-Singlet Exchange in ppˉp\bar{p} Collisions

    Full text link
    A study of the particle multiplicity between jets with large rapidity separation has been performed using the D{\O}detector at the Fermilab Tevatron ppˉp\bar{p} Collider operating at s=1.8\sqrt{s}=1.8 TeV. A significant excess of low-multiplicity events is observed above the expectation for color-exchange processes. The measured fractional excess is 1.07±0.10(stat)0.13+0.25(syst)1.07 \pm 0.10({\rm stat})^{+ 0.25}_{- 0.13}({\rm syst})%, which is consistent with a strongly-interacting color-singlet (colorless) exchange process and cannot be explained by electroweak exchange alone. A lower limit of 0.80% (95% C.L.) is obtained on the fraction of dijet events with color-singlet exchange, independent of the rapidity gap survival probability.Comment: 15 pages (REVTeX), 3 PS figs (uuencoded/tar compressed, epsf.sty) Complete postscript available at http://d0sgi0.fnal.gov/d0pubs/journals.html Submitted to Physical Review Letter

    Construction and test of a fine-grained liquid argon preshower prototype

    Get PDF
    A separate liquid argon preshower detector consisting of two layers featuring a fine granularity of 2.5~103^{\mathrm{-3}} was studied by the RD3 collaboration. A prototype covering approximately 0.8 in pseudo-rapidity and 9 degrees in azimuth was built and tested at CERN in July 94. CMOS and GaAs VLSI preamplifiers were designed and tested for this occasion. The combined response of this detector and an accordion electromagnetic calorimeter prototype to muons, electrons and photons is presented. For minimum ionizing tracks a signal-to-noise ratio of 4.5 per preshower layer was measured. Above 150~GeV the space resolution for electrons is better than 250~μ\mum in both directions. The precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 4 mrad above 50~GeV. It is concluded that the preshower detector would adequately fulfil its role for future operation at CERN Large Hadron Collider

    Test beam results of a stereo preshower integrated in the liquid argon accordion calorimeter

    Get PDF
    This paper describes the construction of an integrated preshower within the RD3 liquid argon accordion calorimeter. It has a stereo view which enables the measurement of two transverse coordinates. The prototype was tested at CERN with electrons, photons and muons to validate its capability to work at LHC ( Energy resolution, impact point resolution, angular resolution, πo\pi^o/γ\gamma rejection )
    corecore