83 research outputs found

    Contemporary European practice in transcatheter aortic valve implantation:results from the 2022 European TAVI Pathway Registry

    Get PDF
    Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77–194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.</p

    Contemporary European practice in transcatheter aortic valve implantation: results from the 2022 European TAVI Pathway Registry

    Get PDF
    BackgroundA steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume.AimsThe 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe.Materials and methodsBetween October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice.ResultsResponses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77–194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%).ConclusionReported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement

    Identification of six new susceptibility loci for invasive epithelial ovarian cancer.

    Get PDF
    Genome-wide association studies (GWAS) have identified 12 epithelial ovarian cancer (EOC) susceptibility alleles. The pattern of association at these loci is consistent in BRCA1 and BRCA2 mutation carriers who are at high risk of EOC. After imputation to 1000 Genomes Project data, we assessed associations of 11 million genetic variants with EOC risk from 15,437 cases unselected for family history and 30,845 controls and from 15,252 BRCA1 mutation carriers and 8,211 BRCA2 mutation carriers (3,096 with ovarian cancer), and we combined the results in a meta-analysis. This new study design yielded increased statistical power, leading to the discovery of six new EOC susceptibility loci. Variants at 1p36 (nearest gene, WNT4), 4q26 (SYNPO2), 9q34.2 (ABO) and 17q11.2 (ATAD5) were associated with EOC risk, and at 1p34.3 (RSPO1) and 6p22.1 (GPX6) variants were specifically associated with the serous EOC subtype, all with P < 5 × 10(-8). Incorporating these variants into risk assessment tools will improve clinical risk predictions for BRCA1 and BRCA2 mutation carriers.COGS project is funded through a European Commission's Seventh Framework Programme grant (agreement number 223175 ] HEALTH ]F2 ]2009 ]223175). The CIMBA data management and data analysis were supported by Cancer Research.UK grants 12292/A11174 and C1287/A10118. The Ovarian Cancer Association Consortium is supported by a grant from the Ovarian Cancer Research Fund thanks to donations by the family and friends of Kathryn Sladek Smith (PPD/RPCI.07). The scientific development and funding for this project were in part supported by the US National Cancer Institute GAME ]ON Post ]GWAS Initiative (U19 ]CA148112). This study made use of data generated by the Wellcome Trust Case Control consortium. Funding for the project was provided by the Wellcome Trust under award 076113. The results published here are in part based upon data generated by The Cancer Genome Atlas Pilot Project established by the National Cancer Institute and National Human Genome Research Institute (dbGap accession number phs000178.v8.p7). The cBio portal is developed and maintained by the Computational Biology Center at Memorial Sloan ] Kettering Cancer Center. SH is supported by an NHMRC Program Grant to GCT. Details of the funding of individual investigators and studies are provided in the Supplementary Note. This study made use of data generated by the Wellcome Trust Case Control consortium, funding for which was provided by the Wellcome Trust under award 076113. The results published here are, in part, based upon data generated by The Cancer Genome Atlas Pilot Project established by the National Cancerhttp://dx.doi.org/10.1038/ng.3185This is the Author Accepted Manuscript of 'Identification of six new susceptibility loci for invasive epithelial ovarian cancer' which was published in Nature Genetics 47, 164–171 (2015) © Nature Publishing Group - content may only be used for academic research

    Identification of 12 new susceptibility loci for different histotypes of epithelial ovarian cancer.

    Get PDF
    To identify common alleles associated with different histotypes of epithelial ovarian cancer (EOC), we pooled data from multiple genome-wide genotyping projects totaling 25,509 EOC cases and 40,941 controls. We identified nine new susceptibility loci for different EOC histotypes: six for serous EOC histotypes (3q28, 4q32.3, 8q21.11, 10q24.33, 18q11.2 and 22q12.1), two for mucinous EOC (3q22.3 and 9q31.1) and one for endometrioid EOC (5q12.3). We then performed meta-analysis on the results for high-grade serous ovarian cancer with the results from analysis of 31,448 BRCA1 and BRCA2 mutation carriers, including 3,887 mutation carriers with EOC. This identified three additional susceptibility loci at 2q13, 8q24.1 and 12q24.31. Integrated analyses of genes and regulatory biofeatures at each locus predicted candidate susceptibility genes, including OBFC1, a new candidate susceptibility gene for low-grade and borderline serous EOC

    stairs and fire

    Get PDF

    Hemodynamics of self-expanding versus balloon-expandable transcatheter heart valves in relation to native aortic annulus anatomy

    No full text
    Objectives This study aimed to compare hemodynamic characteristics of different self-expanding (SE) and balloon-expandable (BE) transcatheter heart valves (THV) in relation to native aortic annulus anatomy. Background A patient centered THV selection becomes increasingly important as indications for transcatheter aortic valve replacement (TAVR) are extended towards lower risk populations. Methods Hemodynamic parameters including mean gradient (MG), effective orifice area (EOA), Doppler velocity index (DVI), degree of paravalvular regurgitation (PVR) and patient-prosthesis mismatch (PPM) were compared by valve type, label size and in relation to quintiles of native aortic annulus area. Results 2609 patients were treated at 3 centers in Germany with SAPIEN 3 (n = 1146), ACURATE Neo (n = 649), Evolut R (n = 546) or Evolut Pro (n = 268) THV. SE THVs provided superior hemodynamics in terms of larger EOA, higher DVI and lower MG compared to BE THV, especially in patients with small aortic annuli. Severe PPM was less frequent in SE treated patients. The rate of PVR >= moderate was comparable for SE and BE devices in smaller annular dimensions, but remarkably lower for BE TAVR in large aortic annular dimensions (> 547.64 mm(2)) (2% BE THV vs. > 10% for SE THV; p = moderate occurs less frequently

    Transcatheter aortic valve implantation with different self-expanding devices—a propensity score-matched multicenter comparison

    No full text
    Objective: Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. Methods: This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. Results: Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. Conclusion: In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities

    Transcatheter Mitral Valve Replacement versus Medical Therapy for Secondary Mitral Regurgitation: A Propensity Score-Matched Comparison.

    No full text
    Background: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. Methods: The CHOICE-MI registry included patients with MR undergoing TMVR using dedicated devices. Patients with MR etiologies other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial. We compared outcomes between the TMVR and GDMT groups, using propensity score (PS)-matching to adjust for baseline differences. Results: After PS-matching, 97 patient pairs undergoing TMVR (72.9±8.7 years, 60.8% male, transapical access 91.8%) versus GDMT (73.1±11.0 years, 59.8% male) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared to 6.9% and 7.7%, respectively, in those receiving GDMT alone (both p<0.001). The 2-year rate of HF hospitalization was significantly lower in the TMVR group (32.8% vs. 54.4%, HR 0.59, 95% CI 0.35-0.99; p=0.04). Among survivors, a higher proportion of patients were in NYHA functional class I or II in the TMVR group at 1 year (78.2% vs. 59.7%, p=0.03) and at 2 years (77.8% vs. 53.2%, p=0.09). Two-year mortality was similar in the two groups (TMVR vs. GDMT, 36.8% vs. 40.8%, HR 1.01, 95% CI 0.62-1.64; p=0.98). Conclusions: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for HF and similar mortality compared with GDMT
    corecore