18 research outputs found

    First Results of the 140^{140}Ce(n,γ)141^{141}Ce Cross-Section Measurement at n_TOF

    Get PDF
    An accurate measurement of the 140^{140}Ce(n,γ) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140^{140}Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140^{140}Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140^{140}Ce Maxwellian-averaged cross-section

    First Results of the 140^{140}Ce(n,γ)141^{141}Ce Cross-Section Measurement at n_TOF

    Get PDF
    An accurate measurement of the 140^{140}Ce(n,γ) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140^{140}Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140^{140}Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140^{140}Ce Maxwellian-averaged cross-section

    Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

    No full text
    This article presents a few selected developments and future ideas related to the measurement of (n, γ) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with γ-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area

    The DESPEC setup for GSI and FAIR

    No full text
    The DEcay SPECtroscopy (DESPEC) setup for nuclear structure investigations was developed and commissioned at GSI, Germany in preparation for a full campaign of experiments at the FRS and Super-FRS. In this paper, we report on the first employment of the setup in the hybrid configuration with the AIDA implanter coupled to the FATIMA LaBr(Ce) fast-timing array, and high-purity germanium detectors. Initial results are shown from the first experiments carried out with the setup. An overview of the setup and function is discussed, including technical advancements along the path

    Summation Calculations for Reactor Antineutrino Spectra, Decay Heat and Delayed Neutron Fractions Involving New TAGS Data and Evaluated Databases

    No full text
    9 pags., 3 figs. -- Open Access funded by Creative Commons Atribution Licence 4.0Three observables of interest for present and future reactors depend on the β decay properties of the fission products: antineutrinos from reactors, the reactor decay heat and delayed neutron emission. In these proceedings, we present new results from summation calculations of the first two quantities quoted above, performed with evolved independent yields coupled with fission product decay data, from various nuclear data bases or models. New TAGS results from the latest experiment of the TAGS collaboration at the JYFL facility of Jyväskylä will be displayed as well as their impact on the antineutrino spectra and the decay heat associated to fission pulses of the main actinides

    First Results of the 140Ce(n,g)141Ce Cross-Section Measurement at n_TOF

    Get PDF
    The cerium oxide material for this measurement was provided by T. Katabuchi of the Tokyo Institute of Technology.An accurate measurement of the 140Ce(n,g) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140Ce Maxwellian-averaged cross-section

    Characterization and performance of the DTAS detector

    No full text
    11 pags., 16 figs., 3 tabs.DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of β-delayed neutron emitting nuclei.This work has been supported by the Spanish Ministerio de Economia y Competitividad under grants FPA2011-24553, AIC-A-2011-0696, FPA2014-52823-C2-1-P and the program Severo Ochoa (SEV-2014-0398), by the European Commission under the FP7/EURATOM contract 605203, and by the Spanish Ministerio de Educacion Cultura y Deporte under the FPU12/01527 grant. The work was also supported by the UK Science and Technology Facilities Council (STFC) grant 14 ST/P005314/1. E. Ganioglu was supported by the Istanbul University Scientic Research Project Unit under FYO-2017-24144 project.Peer Reviewe

    BRAF mutational status is associated with survival outcomes in locally advanced resectable and metastatic NSCLC

    Full text link
    Background: Immunotherapy-based treatments have demonstrated high efficacy in patients with advanced and locally advanced non-small-cell lung cancer (NSCLC). BRAF mutations affect a small but significant fraction of NSCLC. The efficacy of these therapies in this subgroup of patients is unknown. Materials and methods: Plasma and tissue samples from 116 resectable stage IIIA/B NSCLC patients, included in NADIM and NADIM II clinical trials (NADIM cohort), and from a prospective academic cohort with 84 stage IV NSCLC patients (BLI-O cohort), were analyzed by next-generation sequencing. Results: The p.G464E, p.G466R, p.G466V, p.G469V, p.L597Q, p.T599I, p.V600E (n = 2) BRAF mutations, were identified in four (3.45 %) samples from the NADIM cohort, all of which were cases treated with neoadjuvant chemoimmunotherapy (CH-IO), and four (4.76 %) samples from the BLI-O cohort, corresponding to cases treated with first-line immunotherapy (n = 2) or CH-IO (n = 2). All these patients were alive and had no evidence of disease at data cut-off. Conversely, patients with BRAF wild-type (wt) tumors in the BLI-O cohort had a median progression-free survival (PFS) of 5.49 months and a median overall survival (OS) of 12.00 months (P-LogRank = 0.013 and 0.046, respectively). Likewise, PFS and OS probabilities at 36 months were 60.5 % and 76.1 % for patients with BRAF-wt tumors in the NADIM cohort. The pathological complete response (pCR) rate after neoadjuvant CH-IO in patients with BRAF-positive tumors (n = 4) was 100 %, whereas the pCR rate in the BRAF-wt population was 44.3 % (RR: 2.26; 95 % CI: 1.78-2.85; P < 0.001). Conclusion: BRAF mutations may be a good prognostic factor for advanced and locally advanced NSCLC patients undergoing immunotherapy-based treatments

    Measurement of the 14^{14}N(n,p)14^{14}C cross section at the CERN n_TOF facility from sub-thermal energy to 800 keV

    Get PDF
    Background: The 14^{14}N(n,p)14^{14}C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. 10^{10}B(n,α{\alpha})7^7Li and 235^{235}U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809±\pm0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the 14^{14}N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV
    corecore